background image

26284-3-0813

Page 17

1.  If applicable, turn OFF gas supply to vented decorative log 

set.

2.  If applicable, remove gas supply line from vented decorative 

log set.

3. 

For VsM-(18, 24, 30) only,

 remove Natural gas inlet regulator 

from burner assembly.

3. 

For VsR-(18, 24, 30) only,

 remove regulator cap and blue 

conversion screw from HI-LO knob on gas valve.

4. 

For  VsM-(18,  24,  30)

 

only,

 install Propane (LP) gas inlet 

regulator 

marked 10.0

 onto burner assembly.

4. 

For  VsR-(18,  24,  30)

 

only,

 install Propane (LP) gas 

pink 

conversion screw

 into HI-LO knob on gas valve. Assure that 

conversion screw is finger tight (refer to Honeywell conversion 

instructions which are included in conversion kit). Install new 

regulator cap over pink conversion screw.

5.  Remove  Natural  gas  main  burner  orifice  from  orifice  fitting. 

Save the Natural gas main burner orifice from the appliance 

for future use. 

Attention:

 Use appropriate main burner orifice for 

NORMAl

 

input or 

REducEd

 input. 

6.  Install Propane (LP) gas main burner orifice into orifice fitting 

for 

NORMAl

 input.

 

For VsM-18 or VsR-18, 

install one Propane (LP) gas main 

burner orifice 

marked 41

 for 65,000 BTUH input.

 

For VsM-24 or VsR-24,

 install one Propane (LP) gas main 

burner orifice 

marked 40

 for 75,000 BTUH input.

 

For VsM-30 or VsR-30,

 install one Propane (LP) gas main 

burner orifice 

marked 40

 for 75,000 BTUH input.

6.  Install Propane (LP) gas main burner orifice into orifice fitting 

for 

REducEd

 input.

 

For VsM-18 or VsR-18,

 install one Propane (LP) gas main 

burner orifice 

marked 49

 for 40,000 BTUH input.

 

For VsM-24 or VsR-24,

 install one Propane (LP) gas main 

burner orifice 

marked 45

 for 50,000 BTUH input.

 

For VsM-30 or VsR-30,

 install one Propane (LP) gas main 

burner orifice 

marked 43

 for 60,000 BTUH input.

7.  Remove pilot tubing from pilot burner.
8.  Remove Natural gas pilot orifice from pilot burner. Save the 

Natural gas pilot orifice removed from the appliance for future 

use.

9.  Insert  Propane  (LP)  gas  pilot  orifice 

marked  8

 into pilot 

burner.

10.  Attach pilot tubing into pilot burner.
11.  Connect gas supply line to vented decorative log set.
12.  Attach R-1322, conversion label and R-1321, gas conversion 

label to the 4 3/4" x 7 1/4" metal plate supplied in conversion 

kit. Attach 4 3/4" x 7 1/4" metal plate to metal chain which is 

attached to base assembly.

13. 

Pressure Testing of the Gas supply system

a.   To check the inlet pressure to the gas valve, a 1/8" 

(3mm) N.P.T. plugged tapping, accessible for test gauge 

connection, must be placed immediately upstream of the 

gas supply connection to the appliance.

b.  The appliance and its individual shutoff valve must be 

disconnected from the gas supply piping system during 

any pressure testing of that system at test pressures in 

excess of 1/2 psig (3.5 kPa).

c.   The appliance must be isolated from the gas supply piping 

system by closing its individual manual shutoff valve during 

any pressure testing of the gas supply piping system at 

test pressures equal to or less than 1/2 psig (3.5 kPa).

 

Attention!

 If one of the above procedures results in 

pressures in excess of 1/2 psig (14" w.c.) (3.5 kPa) on 

the appliance gas valve, it will result in a hazardous 

condition.

14.  Turn on Propane (LP) gas supply to vented decorative log 

set.

15.  All gas connections must be checked for gas leaks by the 

person  (qualified  agency)  making  the  gas  conversion.  This 

should be done with a soap solution watching for bubbles on 

all exposed connections, and if unexposed, a pressure test 

must be done.

16. Check the appropriate manifold pressure for the vented 

decorative log set according to 

Gas supply

 on Page 8 in this 

manual.

17.  Check pilot burner flame pattern according to 

Pilot and Main 

burner Flame Characteristics

 on Page 12 in this manual.

18.  Check main burner flame pattern according to 

Pilot and Main 

burner Flame Characteristics

 on Page 12 in this manual.

19.  Gas conversion is completed.

Attention: 

The Propane (LP) gas conversion kit must be ordered 

from Empire Comfort Systems, Inc.

PROPANe (lP) GAs CONVeRsION INsTRuCTIONs

Содержание VSM-18-1

Страница 1: ...puis un voisin Suivez les instructions du fournisseur Si vous ne pouvez rejoindre le fournisseur de gaz appelez le service des incendies L installation et l entretien doivent être assurés par un installateur ou un service d entretien qual ifié ou par le fournisseur de gaz AVERTISSEMENT Assurez vous de bien suivre les instructions données dans cette notice pour rédu ire au minimum le risque d incen...

Страница 2: ...ics 12 Wiring 13 Cleaning and Servicing 13 Troubleshooting 14 Parts List 15 Parts View 16 Propane LP Gas Conversion Instructions 17 Natural Gas Conversion Instructions 18 Master Parts Distributor List 19 How To Order Repair Parts 19 Warranty 20 CAUTION If logs or branches are damaged do not use A certain amount of sooting will occur which enhances the realistic look of the logs and branches If an ...

Страница 3: ...turestheapplianceshouldbelocated out of traffic and away from furniture and draperies Children and adults should be alerted to the hazards of high surface temperatures and should stay away to avoid burns or clothing ignition Young children should be carefully supervised when they are in the same room as the appliance Clothingorotherflammablematerialshouldnotbeplaced on or near the appliance Do not...

Страница 4: ...rm service or make adjustments in an area where the conditions are such that you may not detect the odor if there has been a leak of LP Gas Odor fade due to oxidation by rust or adsorption on walls of newcylindersandtanks ispossible Therefore peopleshould be particularly alert and careful when new tanks or cylinders are placed in service Odor fade can occur in new tanks or reinstalled old tanks if...

Страница 5: ... Decorative Appliance and should be installed according to these instructions Any alteration of the original design installed other than as shown in these instructions or use with a type of gas not shown on the rating plate is the responsibility of the person and company making the change Important All correspondence should refer to complete Model Number Serial Number and type of gas Notice During...

Страница 6: ...high altitude applications this appliance is suitable for installation at elevations between 0 feet 0m and 4 500 1 370m without change When installing this unit at an elevation above 4500 feet 1 370m in Canada check with local authorities Consult your local gas utility for assistance in determining the proper orifice for location Turn off gas supply to fireplace or firebox Have the fireplace floor...

Страница 7: ... 6 22 1 28 3 35 3 44 2 15 8 6 12 6 17 3 21 2 26 4 32 2 31 2 20 7 5 10 8 14 5 18 1 22 1 26 4 31 2 25 6 6 9 6 12 6 15 9 18 1 22 9 27 3 30 6 2 9 1 11 3 14 5 17 3 20 4 24 6 35 5 7 8 0 10 8 13 2 15 9 18 9 22 1 40 5 3 7 5 10 2 12 6 15 2 18 1 20 4 Appliance Input Rate KW HR 5 9 8 8 11 7 14 6 17 6 20 5 23 4 Chimney Height m Minimum Opening sq in 3 05 72 9 107 1 142 6 182 6 227 8 285 2 4 57 55 5 81 3 111 6...

Страница 8: ...lve a 1 8 3 175mm N P T pluggedtapping accessiblefortestgaugeconnection must be placed immediately upstream of the gas supply connection to the appliance 2 Theapplianceanditsindividualshutoffvalvemustbedisconnected from the gas supply piping system during any pressure testing of that system at test pressures in excess of 1 2 psig 3 5 kPa 3 Theappliancemustbeisolatedfromthegassupplypipingsystem byc...

Страница 9: ...ate after 10 to 15 minutes the flame appearance should be sets of yellow flames NOTICE all flames will be random by design flame height will go up and down Avoid any drafts that alter burner flame patterns Do not allow fans to blow directly into fireplace Do not place a blower inside the burner area of the firebox Ceiling fans may create drafts that alter flame patterns Sooting and improper burnin...

Страница 10: ...Lighting Instructions FOR YOUR SAFETY READ BEFORE LIGHTING Warning If you do not follow these instructions exactly a fire or explosion may result causing property damage personal injury or loss of life A This appliance has a pilot which must be lighted by hand When lighting the pilot follow these instructions exactly B Before lighting smell all around the appliance area for gas Be sure to smell ne...

Страница 11: ... This appliance has a pilot which must be lighted by hand When lighting the pilot follow these instructions exactly B Before lighting smell all around the appliance area for gas Be sure to smell next to the floor because some gas is heavier than air and will settle on the floor What To Do If You Smell Gas Do not try to light any appliance Do not touch any electrical switch do not use any phone in ...

Страница 12: ...pilot after the pilot orifice has been removed To Remove Pilot Orifice 1 Disconnect the pilot supply line at the pilot burner 2 Remove pilot orifice from pilot burner It may be necessary to tap on pilot burner in order to remove the pilot orifice Pilot Flame Pattern Figure 9 If pilot flame pattern is incorrect See Troubleshooting page 15 Main Burner Flame Pattern The main burner flame will be comp...

Страница 13: ... Check for gas leaks Remote Receiver VSR 18 24 30 Use the following steps to place the remote receiver adjacent to the gas valve Attention 1 The remote receiver can not be placed behind the gas valve and burner assembly 2 When facing the appliance the remote receiver must be placed in the right side firebox toward the front NOTICE Do not let remote control receiver come in contact with burner asse...

Страница 14: ...e Check all connections and try If still not operating disconnect lead between thermo couple switch and valve operator Then disconnect lead to pilot magnet and connect to valve operator terminal TP TH If pilot remains lit fault lies with thermocouple Check that bulb is in proper location If still not working replace thermocouple see drawing in manual for ad ditional information 3 Pilot burning no ...

Страница 15: ...2 R10408 GAS VALVE LPG 12 R10407 GAS VALVE NAT NS R1260 3 8 ELBOW 90 STREET NS R 5910 SWITCH LOG ASSEMBLY NS R 5699 WIRE HARNESS NS R 5757 ON OFF SWITCH NS 26282 TUBING VALVE TO PILOT NS 26283 TUBING VALVE TO BURNER NS 15496 ROCK WOOL NS 11788 DECORATIVE ROCK NS R 2809 DAMPER CLAMP NS R 734 LIGHTER ROD NS R 1054 THERMOPILE VSM 18 24 30 4 P 265 ORIFICE LPG 18 40 000 BTU 4 P 211 ORIFICE NAT 18 40 00...

Страница 16: ...26284 3 0813 Page 16 1 2 3 4 5 6 7 8 9 9 12 10 11 13 14 15 16 17 11 18 19 Parts view ...

Страница 17: ...or future use 9 Insert Propane LP gas pilot orifice marked 8 into pilot burner 10 Attach pilot tubing into pilot burner 11 Connect gas supply line to vented decorative log set 12 Attach R 1322 conversion label and R 1321 gas conversion label to the 4 3 4 x 7 1 4 metal plate supplied in conversion kit Attach 4 3 4 x 7 1 4 metal plate to metal chain which is attached to base assembly 13 Pressure Tes...

Страница 18: ...0 BTUH input 7 Remove pilot tubing from pilot burner 8 Remove Propane LP gas pilot orifice from pilot burner Save the Propane LP gas pilot orifice removed from the appliance for future use 9 Insert Natural gas pilot orifice marked 12 into pilot burner 10 Attach pilot tubing into pilot burner 11 Connect gas supply line to vented decorative log set 12 Attach R 1322 conversion label and R 1320 gas co...

Страница 19: ...ranty parts All parts listed in the Parts List have a Part Number When ordering parts first obtain the Model Number and Serial Number from the name plate on your equipment Then determine the Part Number not the Index Number and the Description of each part from the fol lowing illustration and part list Be sure to give all this information Appliance Model Number Part Description Appliance Serial Nu...

Страница 20: ...wner The appliance must be installed by a qualified installer and operated in accordance with the instructions furnished with the ap pliance A bill of sale cancelled check or payment record should be kept to verify purchase date and establish warranty period Ready access to the appliance for service What Is Not Covered Damages that might result from the use misuse or improper installation of this ...

Отзывы: