background image

26284-3-0813

Page 13

Thermostats are not approved on vented decorated 

appliances.

Label all wires prior to disconnection when servicing controls. Wiring 

errors can cause improper and dangerous operation. Verify proper 

operation after servicing.
VSR gas valve does not require 24 or 110 volts. See Figure 10 to 

provide optional wall switch or remote control. 
It is important to use wire of a gauge proper for the length of the 

wire:

ReCOMMeNded WIRe GAuGes

 

Maximum Length 

Wire Gauge

 

1' to 10' 

18

 

10' to 25' 

16

 

25' to 35' 

14

Use the two leads (black wires) from 

ON/OFF

 switch to attach 

optional components.

Check system Operation

Millivolt system and all individual components may be checked with 

a millivolt meter 0-1000 MV range.

750 Millivolt system

When you ignite the pilot, the thermocouple produces millivolts 

(electrical current) which energizes the magnet in the gas valve. 

After 30 seconds to 1 minute time period you can release the gas 

control knob and the pilot will stay ON. Allow your pilot flame to 

operate an additional one (1) to two (2) minutes before you turn the 

gas control knob from the PILOT position to the ON position. This 

time period allows the millivolts (electrical current) to buildup to a 

sufficient level allowing the gas control to operate properly.   

Millivolt Control

The valve regulator controls the burner pressure which should be 

checked at the pressure test point. Turn captured screw counter 

clockwise 2 or 3 turns and then place tubing to pressure gauge over 

test point (Use test point “A” closest to control knob). After taking 

pressure reading, be sure and turn captured screw clockwise firmly 

to re-seal. Do not over torque. Check for gas leaks.

Remote Receiver

 -

VsR-(18, 24, 30)

Use the following steps to place the 

remote receiver

 adjacent to 

the gas valve.

Attention:

 

1.  The remote receiver 

can not

 be placed behind the gas valve 

and burner assembly.

2.  When facing the appliance, the remote receiver must be placed 

in the 

right

 side firebox, toward the front.

NOTICE

:

 Do not let remote control receiver come in contact with 

burner assembly.
Refer to remote control installation and operating instructions for 

more details on remote control.

VsR Wiring diagram (Figure 10)

 Figure 10

VsR

NOTICE

:  (Wiring harness located in envelope)

Connect the 2 - 1/4" terminals onto the TH and TH/TP terminals 

on valve. Place decorative log to 

right

 of the gas valve and burner 

assembly.

 

When connecting to remote receiver, cut off 1/4" terminals 

from wires attached to ON/OFF switch. Strip wires  back about 1/4". 

Connect stripped ends into remote receiver.

Keep the control compartment, logs and burner area surrounding 

the logs clean.

THE loGs cAN GET VERy HoT— HANdlE oNly WHEN 

COOl.

Always keep the appliance area clear and free from combustible 

materials, gasoline, and other flammable vapors and liquids.
Never obstruct the flow of combustion and ventilation air. Keep the 

front of the appliance clear of all obstacles and materials.

Inspecting Venting system

A  vented  fireplace  venting  system  is  designed  and  constructed 

to develop a positive flow adequate to remove flue gases to the 

outside atmosphere.
Any foreign objects in the venting system, may cause spillage of 

the flue gases into the room. 
Periodic examination and/or cleaning of the venting system of the 

solid-fuel  burning  fireplace  must  be  done  by  a  qualified  service 

person. Visually inspect the damper and flue area for excessive 

soot build-up. This soot (carbon) may be removed by brushing with 

a soft bristle brush. 

WIRING

clEANING ANd sERVIcING

Содержание VSM-18-1

Страница 1: ...puis un voisin Suivez les instructions du fournisseur Si vous ne pouvez rejoindre le fournisseur de gaz appelez le service des incendies L installation et l entretien doivent être assurés par un installateur ou un service d entretien qual ifié ou par le fournisseur de gaz AVERTISSEMENT Assurez vous de bien suivre les instructions données dans cette notice pour rédu ire au minimum le risque d incen...

Страница 2: ...ics 12 Wiring 13 Cleaning and Servicing 13 Troubleshooting 14 Parts List 15 Parts View 16 Propane LP Gas Conversion Instructions 17 Natural Gas Conversion Instructions 18 Master Parts Distributor List 19 How To Order Repair Parts 19 Warranty 20 CAUTION If logs or branches are damaged do not use A certain amount of sooting will occur which enhances the realistic look of the logs and branches If an ...

Страница 3: ...turestheapplianceshouldbelocated out of traffic and away from furniture and draperies Children and adults should be alerted to the hazards of high surface temperatures and should stay away to avoid burns or clothing ignition Young children should be carefully supervised when they are in the same room as the appliance Clothingorotherflammablematerialshouldnotbeplaced on or near the appliance Do not...

Страница 4: ...rm service or make adjustments in an area where the conditions are such that you may not detect the odor if there has been a leak of LP Gas Odor fade due to oxidation by rust or adsorption on walls of newcylindersandtanks ispossible Therefore peopleshould be particularly alert and careful when new tanks or cylinders are placed in service Odor fade can occur in new tanks or reinstalled old tanks if...

Страница 5: ... Decorative Appliance and should be installed according to these instructions Any alteration of the original design installed other than as shown in these instructions or use with a type of gas not shown on the rating plate is the responsibility of the person and company making the change Important All correspondence should refer to complete Model Number Serial Number and type of gas Notice During...

Страница 6: ...high altitude applications this appliance is suitable for installation at elevations between 0 feet 0m and 4 500 1 370m without change When installing this unit at an elevation above 4500 feet 1 370m in Canada check with local authorities Consult your local gas utility for assistance in determining the proper orifice for location Turn off gas supply to fireplace or firebox Have the fireplace floor...

Страница 7: ... 6 22 1 28 3 35 3 44 2 15 8 6 12 6 17 3 21 2 26 4 32 2 31 2 20 7 5 10 8 14 5 18 1 22 1 26 4 31 2 25 6 6 9 6 12 6 15 9 18 1 22 9 27 3 30 6 2 9 1 11 3 14 5 17 3 20 4 24 6 35 5 7 8 0 10 8 13 2 15 9 18 9 22 1 40 5 3 7 5 10 2 12 6 15 2 18 1 20 4 Appliance Input Rate KW HR 5 9 8 8 11 7 14 6 17 6 20 5 23 4 Chimney Height m Minimum Opening sq in 3 05 72 9 107 1 142 6 182 6 227 8 285 2 4 57 55 5 81 3 111 6...

Страница 8: ...lve a 1 8 3 175mm N P T pluggedtapping accessiblefortestgaugeconnection must be placed immediately upstream of the gas supply connection to the appliance 2 Theapplianceanditsindividualshutoffvalvemustbedisconnected from the gas supply piping system during any pressure testing of that system at test pressures in excess of 1 2 psig 3 5 kPa 3 Theappliancemustbeisolatedfromthegassupplypipingsystem byc...

Страница 9: ...ate after 10 to 15 minutes the flame appearance should be sets of yellow flames NOTICE all flames will be random by design flame height will go up and down Avoid any drafts that alter burner flame patterns Do not allow fans to blow directly into fireplace Do not place a blower inside the burner area of the firebox Ceiling fans may create drafts that alter flame patterns Sooting and improper burnin...

Страница 10: ...Lighting Instructions FOR YOUR SAFETY READ BEFORE LIGHTING Warning If you do not follow these instructions exactly a fire or explosion may result causing property damage personal injury or loss of life A This appliance has a pilot which must be lighted by hand When lighting the pilot follow these instructions exactly B Before lighting smell all around the appliance area for gas Be sure to smell ne...

Страница 11: ... This appliance has a pilot which must be lighted by hand When lighting the pilot follow these instructions exactly B Before lighting smell all around the appliance area for gas Be sure to smell next to the floor because some gas is heavier than air and will settle on the floor What To Do If You Smell Gas Do not try to light any appliance Do not touch any electrical switch do not use any phone in ...

Страница 12: ...pilot after the pilot orifice has been removed To Remove Pilot Orifice 1 Disconnect the pilot supply line at the pilot burner 2 Remove pilot orifice from pilot burner It may be necessary to tap on pilot burner in order to remove the pilot orifice Pilot Flame Pattern Figure 9 If pilot flame pattern is incorrect See Troubleshooting page 15 Main Burner Flame Pattern The main burner flame will be comp...

Страница 13: ... Check for gas leaks Remote Receiver VSR 18 24 30 Use the following steps to place the remote receiver adjacent to the gas valve Attention 1 The remote receiver can not be placed behind the gas valve and burner assembly 2 When facing the appliance the remote receiver must be placed in the right side firebox toward the front NOTICE Do not let remote control receiver come in contact with burner asse...

Страница 14: ...e Check all connections and try If still not operating disconnect lead between thermo couple switch and valve operator Then disconnect lead to pilot magnet and connect to valve operator terminal TP TH If pilot remains lit fault lies with thermocouple Check that bulb is in proper location If still not working replace thermocouple see drawing in manual for ad ditional information 3 Pilot burning no ...

Страница 15: ...2 R10408 GAS VALVE LPG 12 R10407 GAS VALVE NAT NS R1260 3 8 ELBOW 90 STREET NS R 5910 SWITCH LOG ASSEMBLY NS R 5699 WIRE HARNESS NS R 5757 ON OFF SWITCH NS 26282 TUBING VALVE TO PILOT NS 26283 TUBING VALVE TO BURNER NS 15496 ROCK WOOL NS 11788 DECORATIVE ROCK NS R 2809 DAMPER CLAMP NS R 734 LIGHTER ROD NS R 1054 THERMOPILE VSM 18 24 30 4 P 265 ORIFICE LPG 18 40 000 BTU 4 P 211 ORIFICE NAT 18 40 00...

Страница 16: ...26284 3 0813 Page 16 1 2 3 4 5 6 7 8 9 9 12 10 11 13 14 15 16 17 11 18 19 Parts view ...

Страница 17: ...or future use 9 Insert Propane LP gas pilot orifice marked 8 into pilot burner 10 Attach pilot tubing into pilot burner 11 Connect gas supply line to vented decorative log set 12 Attach R 1322 conversion label and R 1321 gas conversion label to the 4 3 4 x 7 1 4 metal plate supplied in conversion kit Attach 4 3 4 x 7 1 4 metal plate to metal chain which is attached to base assembly 13 Pressure Tes...

Страница 18: ...0 BTUH input 7 Remove pilot tubing from pilot burner 8 Remove Propane LP gas pilot orifice from pilot burner Save the Propane LP gas pilot orifice removed from the appliance for future use 9 Insert Natural gas pilot orifice marked 12 into pilot burner 10 Attach pilot tubing into pilot burner 11 Connect gas supply line to vented decorative log set 12 Attach R 1322 conversion label and R 1320 gas co...

Страница 19: ...ranty parts All parts listed in the Parts List have a Part Number When ordering parts first obtain the Model Number and Serial Number from the name plate on your equipment Then determine the Part Number not the Index Number and the Description of each part from the fol lowing illustration and part list Be sure to give all this information Appliance Model Number Part Description Appliance Serial Nu...

Страница 20: ...wner The appliance must be installed by a qualified installer and operated in accordance with the instructions furnished with the ap pliance A bill of sale cancelled check or payment record should be kept to verify purchase date and establish warranty period Ready access to the appliance for service What Is Not Covered Damages that might result from the use misuse or improper installation of this ...