![Empire SR-10TBC-3 Скачать руководство пользователя страница 9](http://html1.mh-extra.com/html/empire/sr-10tbc-3/sr-10tbc-3_installation-instructions-and-owners-manual_2403700009.webp)
16011-9-0314
Page 9
When facing the front of the appliance the following minimum
clearances to combustible construction must be maintained.
Left side 6 inches (152mm). Right side 6 inches (152mm).
Do not install in alcove or closet.
Rear wall 0 inches (0mm). Ceiling 36 inches (914mm).
Minimum vertical clearance from a projection above the
appliance (shelves, window sills, etc.) 36 inches (914mm).
Floor (top surface of carpeting, tile, etc.) 2 inches (51mm).
Provide adequate clearances around air openings.
Adequate accessibility clearances for purposes of servicing and
proper operation must be provided.
CEILING
SIDE WALL
36”MIN
(914mm)
6” MIN
(152mm)
6”MIN
(152mm)
2”MIN
(51mm)
FLOOR
Figure 5 (SR-18T)
SR-18T CLEARANCES