Empire SR-10TBC-3 Скачать руководство пользователя страница 24

16011-9-0314

Page 24

EMPIRE

EMPIRE

Comfort Systems

Empire Comfort Systems Inc.

918 Freeburg Ave. Belleville, IL  62220

If you have a general question about our products, please e-mail us 

at [email protected]

If you have a service or repair question, please contact your dealer.

www.empirecomfort.com

WARRANTY

Empire Comfort Systems Inc. warranties this space heating product to be free from defects at the time of purchase and for 

the periods specified below.  Space heating products must be installed by a qualified technician and must be maintained 

and operated safely, in accordance with the instructions in the owner’s manual.  This warranty applies to the original pur-

chaser only and is not transferable.  All warranty repairs must be accomplished by a qualified gas appliance technician.

Limited Lifetime Parts Warranty with a Five-Year Limited Labor Warranty – 

Combustion Chamber and Heat Exchanger

 I

f the combustion chamber or heat exchanger (see parts list) fails because of defective workmanship or material,    

 

Empire will repair or replace at Empire’s option.

 

Within five years from the date of purchase, Empire will pay reasonable labor to have the defective part repaired or 

 

replaced at Empire’s option.

Limited Five-Year Parts & Labor Warranty – All Other Components (Except Thermostats)

 

Should any part fail because of defective workmanship or material within five years from the date of purchase, 

 

Empire will repair or replace at Empire’s option.

 

Within five years from the date of purchase, Empire will pay reasonable labor to have that defect repaired at 

 

Empire’s option.

Limited One-Year Parts Warranty – Remote Controls, Thermostats, Accessories, and Parts

 

Should any remote control, thermostat, accessory, or other part fail because of defective workmanship within one   

 

year from the date of purchase, Empire will repair or replace at Empire’s option.

 

Duties of the Owner

 

The appliance must be installed by a qualified installer and operated in accordance with the instructions furnished   

 

with the appliance.

 

A bill of sale, cancelled check, or payment record should be kept to verify purchase date and establish warranty    

 period.

 

Ready access to the appliance for service.

What Is Not Covered

 

Damages that might result from the use, misuse, or improper installation of this appliance.

 

Travel, diagnostic costs and freight charges on warranted parts to and from the factory.

 

Claims that do not involve defective workmanship or materials.

 

Unauthorized service or parts replacements.

 

Removal and reinstallation cost.

 

Inoperable due to improper or lack of maintenance.

How To Get Service

 

To make a claim under this warranty, please have your receipt available and contact your installing dealer.   

 

Provide the dealer with the model number, serial number, type of gas, and purchase verification.  The  

 

installing dealer is responsible for providing service and will contact the factory to initiate any warranted   

 

parts replacements.  Empire will make replacement parts available at the factory.  Shipping expenses are   

 

not covered.

 

If, after contacting your Empire dealer, service received has not been satisfactory, 

 

contact: Consumer Relations Department, Empire Comfort Systems Inc., PO Box 529, Belleville, Illinois    

 

62222, or send an e-mail to [email protected] with “Consumer Relations” in the subject line.

 

Your Rights Under State Law

 

This warranty gives your specific legal rights, and you may also have other rights, 

 

which vary from state to  state.  

Содержание SR-10TBC-3

Страница 1: ...which shall limit the appliance input to a maximum of 20 BTUH per cubic foot of room space Unvented room heaters are NOT FOR COMMERCIAL OR INDUSTRIAL USE WATERVAPOR ABY PRODUCT OF UNVENTEDROOM HEATER...

Страница 2: ...arances 8 SR 18T Clearances 9 Wall Mount Installation 10 Optional Floor Stand Installation 11 Lighting Instructions 12 Main Burner Flame Characteristics 13 Pilot Flame Characteristics 14 Thermostat Op...

Страница 3: ...ced prior to operating the heater Keep appliance area clear and free from combustible materials gasoline and other flammable vapors and liquids WARNING Failure to keep the primary air opening s of the...

Страница 4: ...hts perform service or make adjustments in an area where the conditions are such that you may not detect the odor if there has been a leak of LP Gas Odor fade due to oxidation by rust or adsorption on...

Страница 5: ...d type of gas Well Head Gas Installations Some natural gas utilities use well head gas This may affect the Btuoutputoftheunit Contactthegascompanyfortheheatingvalue Contact the manufacturer or your ga...

Страница 6: ...which the SR 18TBC may be located and for determining if this area fits the definition of an unconfined space The input of the SR 18TBC is 18 000 Btu per hour Based on the 50 cubic feet per 1 000 Btu...

Страница 7: ...1 24Appliance Connectors of Corrugated MetalTubing and Fittings ANSZ21 45AssembledFlexibleApplianceConnectorsofOther Than All Metal Construction The above connectors may be used if acceptable by the a...

Страница 8: ...inches 356mm Maximumhorizontalextensionofprojectionabovetheappliance 12 inches 305mm Floor top surface of carpeting tile etc 2 inches 51mm Provide adequate clearances around air openings Adequate acce...

Страница 9: ...s 0mm Ceiling 36 inches 914mm Minimum vertical clearance from a projection above the appliance shelves window sills etc 36 inches 914mm Floor top surface of carpeting tile etc 2 inches 51mm Provide ad...

Страница 10: ...eads into the wall Attention Use the following steps to properly align the upper louver and the reflector with the heat shield a Whenreplacingupperlouver besurethebottomlipofupper louver goes behind t...

Страница 11: ...f this appliance is installed directly on carpeting tile or other com bustible material other than wood flooring the appliance shall be installed on a metal or wood panel extending the full width and...

Страница 12: ...ntrol knob to lowest setting 3 Turn off all electric power to the appliance if applica ble 4 Push in gas control knob slightly and turn clockwise to OFF Do not force 5 Wait ten 10 minutes to clear out...

Страница 13: ...ect interior of casing assembly for accumulation of dust lint or spider webs If necessary clean interior of casing assembly with a vacuum cleaner or apply air pressure Do not damage any components wit...

Страница 14: ...bulb is satisfied the burner will shut OFF with the pilot flame remaining ON The SR 18T has an input of 18 000 BTUH 5 3KW H The hydraulic thermostat bulb is located at the casing assembly bottom When...

Страница 15: ...ater 3 Remove lower louver from casing assembly 2 screws 4 Remove reflector from casing assembly 2 screws 5 Remove upper louver from casing assembly 2 screws 6 If installed remove optional blower asse...

Страница 16: ...etely depressed or held in long enough b INTERLOCK latching device is operative see Lighting Instructions Page 12 Step 9 c Thermocouple not tightened into gas control tighten thermocouple d Pilot flam...

Страница 17: ...RE PACKAGE NS NOT SHOWN USE ONLY MANUFACTURED REPLACEMENT PARTS USE OF ANY OTHER PARTS COULD CAUSE INJURY OR DEATH PLEASE NOTE When ordering parts it is very important that part number and description...

Страница 18: ...16011 9 0314 Page 18 SR 10T PARTS VIEW...

Страница 19: ...16011 9 0314 Page 19 SR 18T PARTS VIEW...

Страница 20: ...anty parts All parts listed in the Parts List have a Part Number When ordering parts first obtain the Model Number and Serial Number from the name plate on your equipment Then determine the Part Numbe...

Страница 21: ...the blower housing with 1 screw provided with the optional blower 12 With the heater standing upright position the air discharge opening of the blower housing downward Place the bottom flange of the b...

Страница 22: ...r wheel will collect lint and could require periodic cleaning If the air output decreases or the noise level increases it indicates a dirty blower wheel To clean blower wheel 1 Turn OFF gas supply to...

Страница 23: ...16011 9 0314 Page 23 APPLIANCE SERVICE HISTORY Date Dealer Name Service Technician Name Service Performed Notes...

Страница 24: ...mote Controls Thermostats Accessories and Parts Should any remote control thermostat accessory or other part fail because of defective workmanship within one year from the date of purchase Empire will...

Отзывы: