FOR YOUR SAFETY READ BEFORE LIGHTING

WARNING:

 If you do not follow these instructions exactly, a fire or explosion may 

result causing property damage, personal injury or loss of life.

A.   This  appliance  has  a  pilot  which  must  be  lighted  by 

hand. When lighting the pilot, follow these instructions 

exactly.

B.  

BEFORE LIGHTING 

smell all around the appliance area 

for gas. Be sure to smell next to the floor because some 

gas is heavier than air and will settle on the floor.

 

WHAT TO DO IF YOU SMELL GAS

• Do not try to light any appliance.

• Do not touch any electrical switch; 

  do not use any phone in your building.

• Immediately call your gas supplier from a neighbor’s 

phone. Follow the gas supplier’s instructions.

• If you cannot reach your gas supplier, call the fire 

department.

C.   Use only your hand to push in or turn the gas control 

knob.  Never  use  tools.  If  the  knob  will  not  push  in  or 

turn by hand, don’t try to repair it; call a qualified service 

technician. Force or attempted repair may result in a fire 

or explosion.

D.   Do not use this appliance if any part has been under water. 

Immediately call a qualified service technician to inspect 

the appliance and to replace any part of the control system 

and any gas control which has been under water.

TO TURN OFF GAS TO APPLIANCE

1.   Set thermostat (gas control knob) to lowest setting.
2.   Turn off all electric power to appliance if service is to be 

performed (if applicable).

3.   Push in gas control knob slightly and turn clockwise 

 to “OFF”. Do not force.

LIGHTING INSTRUCTIONS

1.   STOP!  Read the safety information above.
2.  Set thermostat (gas control knob) to lowest setting.
3.  Turn off all electric power to the appliance (if applica

-

ble).

4.   Push  in  gas  control  knob  slightly  and  turn  clockwise   

 to “OFF”. Do not force.

5.   Wait ten (10) minutes  to clear out any gas. Then smell 

for gas, including near the floor. If you smell gas, STOP! 

Follow “B” in the safety information above. If you don’t 

smell gas, go to the next step.

6.   Find pilot - the pilot is attached 

at  the  bottom  of  the  burner 

 

assembly .

7.   Turn gas control knob

 

counterclockwise

  to 

“PILOT.”

8.   Push in gas control knob all the way and hold in. Repeat

-

edly push the piezo ignitor button until pilot is lit (or use 

a match to light pilot). Continue to hold the control knob 

in for about one (1) minute after the pilot is lit. Release 

knob and it will pop back up. Pilot should remain lit. If it 

goes out, repeat steps 4 through 8.

•  If knob does not pop up when released, stop and 

immediately  call  your  service  technician  or  gas 

supplier. 

•  If the pilot will not stay lit after several tries, turn 

the gas control knob to “OFF” and call your service 

technician or gas supplier. 

9.  Attention! Gas control has an INTERLOCK latching de

-

vice. When the pilot is initially lit and the safety magnet 

is energized (pilot stays “ON”) the INTERLOCK latching 

device becomes operative. If the gas control is turned to 

the “OFF” position or gas flow to the appliance is shut 

off, the pilot cannot be relighted until the safety magnet 

is de-energized (approximately 60 seconds). There will 

be an audible “click” when the safety magnet in the gas 

control is de-energized. Pilot can now be relighted. Repeat 

steps 4 through 8.

10.  Turn  gas  control  knob  counterclockwise 

  to 

“HI”. 

11.  Turn on all electric power to appliance (if applicable).

12.  Set thermostat (gas control knob) to desired setting from 

“HI” to “LO”.

LIGHTING INSTRUCTIONS

Содержание SR-10TBC-3

Страница 1: ...which shall limit the appliance input to a maximum of 20 BTUH per cubic foot of room space Unvented room heaters are NOT FOR COMMERCIAL OR INDUSTRIAL USE WATERVAPOR ABY PRODUCT OF UNVENTEDROOM HEATER...

Страница 2: ...arances 8 SR 18T Clearances 9 Wall Mount Installation 10 Optional Floor Stand Installation 11 Lighting Instructions 12 Main Burner Flame Characteristics 13 Pilot Flame Characteristics 14 Thermostat Op...

Страница 3: ...ced prior to operating the heater Keep appliance area clear and free from combustible materials gasoline and other flammable vapors and liquids WARNING Failure to keep the primary air opening s of the...

Страница 4: ...hts perform service or make adjustments in an area where the conditions are such that you may not detect the odor if there has been a leak of LP Gas Odor fade due to oxidation by rust or adsorption on...

Страница 5: ...d type of gas Well Head Gas Installations Some natural gas utilities use well head gas This may affect the Btuoutputoftheunit Contactthegascompanyfortheheatingvalue Contact the manufacturer or your ga...

Страница 6: ...which the SR 18TBC may be located and for determining if this area fits the definition of an unconfined space The input of the SR 18TBC is 18 000 Btu per hour Based on the 50 cubic feet per 1 000 Btu...

Страница 7: ...1 24Appliance Connectors of Corrugated MetalTubing and Fittings ANSZ21 45AssembledFlexibleApplianceConnectorsofOther Than All Metal Construction The above connectors may be used if acceptable by the a...

Страница 8: ...inches 356mm Maximumhorizontalextensionofprojectionabovetheappliance 12 inches 305mm Floor top surface of carpeting tile etc 2 inches 51mm Provide adequate clearances around air openings Adequate acce...

Страница 9: ...s 0mm Ceiling 36 inches 914mm Minimum vertical clearance from a projection above the appliance shelves window sills etc 36 inches 914mm Floor top surface of carpeting tile etc 2 inches 51mm Provide ad...

Страница 10: ...eads into the wall Attention Use the following steps to properly align the upper louver and the reflector with the heat shield a Whenreplacingupperlouver besurethebottomlipofupper louver goes behind t...

Страница 11: ...f this appliance is installed directly on carpeting tile or other com bustible material other than wood flooring the appliance shall be installed on a metal or wood panel extending the full width and...

Страница 12: ...ntrol knob to lowest setting 3 Turn off all electric power to the appliance if applica ble 4 Push in gas control knob slightly and turn clockwise to OFF Do not force 5 Wait ten 10 minutes to clear out...

Страница 13: ...ect interior of casing assembly for accumulation of dust lint or spider webs If necessary clean interior of casing assembly with a vacuum cleaner or apply air pressure Do not damage any components wit...

Страница 14: ...bulb is satisfied the burner will shut OFF with the pilot flame remaining ON The SR 18T has an input of 18 000 BTUH 5 3KW H The hydraulic thermostat bulb is located at the casing assembly bottom When...

Страница 15: ...ater 3 Remove lower louver from casing assembly 2 screws 4 Remove reflector from casing assembly 2 screws 5 Remove upper louver from casing assembly 2 screws 6 If installed remove optional blower asse...

Страница 16: ...etely depressed or held in long enough b INTERLOCK latching device is operative see Lighting Instructions Page 12 Step 9 c Thermocouple not tightened into gas control tighten thermocouple d Pilot flam...

Страница 17: ...RE PACKAGE NS NOT SHOWN USE ONLY MANUFACTURED REPLACEMENT PARTS USE OF ANY OTHER PARTS COULD CAUSE INJURY OR DEATH PLEASE NOTE When ordering parts it is very important that part number and description...

Страница 18: ...16011 9 0314 Page 18 SR 10T PARTS VIEW...

Страница 19: ...16011 9 0314 Page 19 SR 18T PARTS VIEW...

Страница 20: ...anty parts All parts listed in the Parts List have a Part Number When ordering parts first obtain the Model Number and Serial Number from the name plate on your equipment Then determine the Part Numbe...

Страница 21: ...the blower housing with 1 screw provided with the optional blower 12 With the heater standing upright position the air discharge opening of the blower housing downward Place the bottom flange of the b...

Страница 22: ...r wheel will collect lint and could require periodic cleaning If the air output decreases or the noise level increases it indicates a dirty blower wheel To clean blower wheel 1 Turn OFF gas supply to...

Страница 23: ...16011 9 0314 Page 23 APPLIANCE SERVICE HISTORY Date Dealer Name Service Technician Name Service Performed Notes...

Страница 24: ...mote Controls Thermostats Accessories and Parts Should any remote control thermostat accessory or other part fail because of defective workmanship within one year from the date of purchase Empire will...

Отзывы: