Water vapor is a by-product of gas combustion. An unvented room 

heater produces approximately one (1) ounce (30ml) of water for 

every 1,000 BTU’s (.3KW’s) of gas input per hour. 
Unvented room heaters must be used as supplemental heat (a 

room) rather than a primary heat source (an entire house). In most 

supplemental heat applications, the water vapor does not create a 

problem. In most applications, the water vapor enhances the low 

humidity atmosphere experienced during cold weather. 

The following steps will help insure that water vapor does not 

become a problem.  

1.  Be sure the heater is sized properly for the application, including 

ample combustion air and circulation air.

2.  If high humidity is experienced, a dehumidifier may be used to 

help lower the water vapor content of the air.

3.  Do not use an unvented room heater as the primary heat source 

(an entire house).

This heater shall not be installed in a confined space or unusually 

tight construction unless provisions are provided for adequate 

combustion and ventilation air.

A confined space is an area with volume less than 50 cubic feet per 

1,000 Btuh of the combined input rates of all appliances drawing 

combustion air from that space. Small areas such as equipment 

rooms are confined spaces. Furnaces installed in a confined space 

which supply heated air to areas outside the space must draw return 

air from outside the space through tightly sealed return air ducts. A 

confined space must have 2 openings into the space fro combustion 

air. One opening must be within 12 inches of the ceiling and the 

other must be within 12 inches of the floor. The required sizing of 

these openings is determined by whether inside or outside air is 

used to support combustion, the method by which the air is brought 

to the space (vertical or horizontal duct) and by the total input rate 

of all appliances in the space.
The following example is for determining the volume of a typical 

area in which the SR-18TBC may be located and for determining if 

this area fits the definition of an unconfined space.

The input of the SR-18TBC is 18,000 Btu per hour.  Based on the 50 

cubic feet per 1,000 Btu per hour formula, the 

minimum

 area that is 

an unconfined space for installation of the SR-18TBC is 900 cubic 

feet, 50 cubic feet x 18 = 900 cubic feet. To determine the cubic feet 

of the area in which the SR-18TBC is to be installed, measure the 

length, width and height of the area.  Example:  The area measures 

13 feet in length, 9 feet in width and 8 feet in height, the area is 936 

cubic feet.  The SR-18TBC can be installed in this unconfined space 

with no requirement to provide additional combustion and ventilation 

air. 

Warning:

 If the area in which the heater may be operated is 

smaller than that defined as an unconfined space or if the building 

is of unusually tight construction, provide adequate combustion and 

ventilation air by one of the methods described in the National Fuel 

Gas Code, ANSI Z223.1/NFPA 54, Air for Combustion and Ventila-

tion or applicable local codes.

Unusually Tight Construction

The air that leaks around doors and windows may provide enough 

fresh air for combustion and ventilation. However, in buildings of 

unusually tight construction, you must provide additional fresh air.

  Unusually  tight  construction  is  defined  as  construction 

where:

a.  Walls and ceilings exposed to the outside atmosphere have 

a continuous water vapor retarder with a rating of one perm 

or less with openings gasketed or sealed, and

b.  Weatherstripping has been added on openable windows and 

doors, and

c.  Caulking or sealants are applied to areas such as joints 

around window and door frames, between sole plates and 

floors, between wall-ceiling joints, between wall panels, at 

penetrations for plumbing, electrical, and gas lines, and at 

other openings. 

If the SR-8TBC heater is installed in a building of unusually tight 

construction, adequate air for combustion, ventilation and dilution 

of flue gases shall be provided in accordance with ANSI Z223.1/

NFPA54.

PROVISIONS FOR ADEQUATE COMBUSTION & VENTILATION AIR

WATER VAPOR: A BY-PRODUCT OF UNVENTED ROOM HEATERS

Содержание SR-10TBC-3

Страница 1: ...which shall limit the appliance input to a maximum of 20 BTUH per cubic foot of room space Unvented room heaters are NOT FOR COMMERCIAL OR INDUSTRIAL USE WATERVAPOR ABY PRODUCT OF UNVENTEDROOM HEATER...

Страница 2: ...arances 8 SR 18T Clearances 9 Wall Mount Installation 10 Optional Floor Stand Installation 11 Lighting Instructions 12 Main Burner Flame Characteristics 13 Pilot Flame Characteristics 14 Thermostat Op...

Страница 3: ...ced prior to operating the heater Keep appliance area clear and free from combustible materials gasoline and other flammable vapors and liquids WARNING Failure to keep the primary air opening s of the...

Страница 4: ...hts perform service or make adjustments in an area where the conditions are such that you may not detect the odor if there has been a leak of LP Gas Odor fade due to oxidation by rust or adsorption on...

Страница 5: ...d type of gas Well Head Gas Installations Some natural gas utilities use well head gas This may affect the Btuoutputoftheunit Contactthegascompanyfortheheatingvalue Contact the manufacturer or your ga...

Страница 6: ...which the SR 18TBC may be located and for determining if this area fits the definition of an unconfined space The input of the SR 18TBC is 18 000 Btu per hour Based on the 50 cubic feet per 1 000 Btu...

Страница 7: ...1 24Appliance Connectors of Corrugated MetalTubing and Fittings ANSZ21 45AssembledFlexibleApplianceConnectorsofOther Than All Metal Construction The above connectors may be used if acceptable by the a...

Страница 8: ...inches 356mm Maximumhorizontalextensionofprojectionabovetheappliance 12 inches 305mm Floor top surface of carpeting tile etc 2 inches 51mm Provide adequate clearances around air openings Adequate acce...

Страница 9: ...s 0mm Ceiling 36 inches 914mm Minimum vertical clearance from a projection above the appliance shelves window sills etc 36 inches 914mm Floor top surface of carpeting tile etc 2 inches 51mm Provide ad...

Страница 10: ...eads into the wall Attention Use the following steps to properly align the upper louver and the reflector with the heat shield a Whenreplacingupperlouver besurethebottomlipofupper louver goes behind t...

Страница 11: ...f this appliance is installed directly on carpeting tile or other com bustible material other than wood flooring the appliance shall be installed on a metal or wood panel extending the full width and...

Страница 12: ...ntrol knob to lowest setting 3 Turn off all electric power to the appliance if applica ble 4 Push in gas control knob slightly and turn clockwise to OFF Do not force 5 Wait ten 10 minutes to clear out...

Страница 13: ...ect interior of casing assembly for accumulation of dust lint or spider webs If necessary clean interior of casing assembly with a vacuum cleaner or apply air pressure Do not damage any components wit...

Страница 14: ...bulb is satisfied the burner will shut OFF with the pilot flame remaining ON The SR 18T has an input of 18 000 BTUH 5 3KW H The hydraulic thermostat bulb is located at the casing assembly bottom When...

Страница 15: ...ater 3 Remove lower louver from casing assembly 2 screws 4 Remove reflector from casing assembly 2 screws 5 Remove upper louver from casing assembly 2 screws 6 If installed remove optional blower asse...

Страница 16: ...etely depressed or held in long enough b INTERLOCK latching device is operative see Lighting Instructions Page 12 Step 9 c Thermocouple not tightened into gas control tighten thermocouple d Pilot flam...

Страница 17: ...RE PACKAGE NS NOT SHOWN USE ONLY MANUFACTURED REPLACEMENT PARTS USE OF ANY OTHER PARTS COULD CAUSE INJURY OR DEATH PLEASE NOTE When ordering parts it is very important that part number and description...

Страница 18: ...16011 9 0314 Page 18 SR 10T PARTS VIEW...

Страница 19: ...16011 9 0314 Page 19 SR 18T PARTS VIEW...

Страница 20: ...anty parts All parts listed in the Parts List have a Part Number When ordering parts first obtain the Model Number and Serial Number from the name plate on your equipment Then determine the Part Numbe...

Страница 21: ...the blower housing with 1 screw provided with the optional blower 12 With the heater standing upright position the air discharge opening of the blower housing downward Place the bottom flange of the b...

Страница 22: ...r wheel will collect lint and could require periodic cleaning If the air output decreases or the noise level increases it indicates a dirty blower wheel To clean blower wheel 1 Turn OFF gas supply to...

Страница 23: ...16011 9 0314 Page 23 APPLIANCE SERVICE HISTORY Date Dealer Name Service Technician Name Service Performed Notes...

Страница 24: ...mote Controls Thermostats Accessories and Parts Should any remote control thermostat accessory or other part fail because of defective workmanship within one year from the date of purchase Empire will...

Отзывы: