INSTALLATION INSTRUCTIONS

AND

OWNER’S MANUAL

UNVENTED 

ROOM HEATER

MODELS

SR-10TBC-3      SR-18TBC-3

SR-18T SHOWN

This is an unvented gas-fired heater.  It uses air (oxy

-

gen) from the room in which it is installed.  Provisions 

for adequate combustion and ventilation air must be 

provided. Refer to page 6.

WARNING: If not installed, operated and maintained 

in accordance with the manufacturer’s instructions, 

this product could expose you to substances in fuel 

or from fuel combustion which can cause death or 

serious illness.

Unvented room heaters are for installation in SINGLE 

FAMILY TYPE RESIDENCES ONLY,  and the installation 

is limited to ONE (1) unit per residence.

Unvented  room  heaters  are  NOT  TO  BE  USED  IN 

BEDROOMS, MOBILE HOMES, TRAILERS AND REC

-

REATIONAL VEHICLES.

Unvented room heaters are only to be used as supple

-

mentary heat and NOT AS PRINCIPAL SOURCE OF 

HEAT for the room in which the unit is installed.

Unvented  room  heaters  are  not  for  installation  in 

rooms having space which shall limit the appliance 

input to a maximum of “20 BTUH” per cubic foot of 

room space.

Unvented room heaters are NOT FOR COMMERCIAL 

OR INDUSTRIAL USE.

WATER VAPOR: A BY-PRODUCT OF UNVENTED ROOM 

HEATERS

Water  vapor  is  a  by-product  of  gas  combustion. An 

unvented room heater produces approximately one (1) 

ounce (30ml) of water for every 1,000 BTU’s (.3KW’s) 

of gas input per hour. Refer to page 6.

Installer: 

Leave this manual with the appliance.

Consumer:  Retain this manual for future reference.

—  Do not store or use gasoline or other flammable 

vapors and liquids in the vicinity of this or any 

other appliance.

—  WHAT TO DO IF YOU SMELL GAS

 

•  Do not try to light any appliance.

 

•  Do not touch any electrical switch; do not use 

any phone in your building.

 

•  Immediately  call  your  gas  supplier  from  a 

neighbor’s phone. Follow the gas supplier’s 

instructions.

 

•  If you cannot reach your gas supplier, call the 

fire department.

—  Installation and service must be performed by a 

qualified installer, service agency or the gas sup

-

plier.

WARNING: If the information in these instructions 

are  not  followed  exactly,  a  fire  or  explosion  may 

result causing property damage, personal injury or 

loss of life.

Page 1

Содержание SR-10TBC-3

Страница 1: ...which shall limit the appliance input to a maximum of 20 BTUH per cubic foot of room space Unvented room heaters are NOT FOR COMMERCIAL OR INDUSTRIAL USE WATERVAPOR ABY PRODUCT OF UNVENTEDROOM HEATER...

Страница 2: ...arances 8 SR 18T Clearances 9 Wall Mount Installation 10 Optional Floor Stand Installation 11 Lighting Instructions 12 Main Burner Flame Characteristics 13 Pilot Flame Characteristics 14 Thermostat Op...

Страница 3: ...ced prior to operating the heater Keep appliance area clear and free from combustible materials gasoline and other flammable vapors and liquids WARNING Failure to keep the primary air opening s of the...

Страница 4: ...hts perform service or make adjustments in an area where the conditions are such that you may not detect the odor if there has been a leak of LP Gas Odor fade due to oxidation by rust or adsorption on...

Страница 5: ...d type of gas Well Head Gas Installations Some natural gas utilities use well head gas This may affect the Btuoutputoftheunit Contactthegascompanyfortheheatingvalue Contact the manufacturer or your ga...

Страница 6: ...which the SR 18TBC may be located and for determining if this area fits the definition of an unconfined space The input of the SR 18TBC is 18 000 Btu per hour Based on the 50 cubic feet per 1 000 Btu...

Страница 7: ...1 24Appliance Connectors of Corrugated MetalTubing and Fittings ANSZ21 45AssembledFlexibleApplianceConnectorsofOther Than All Metal Construction The above connectors may be used if acceptable by the a...

Страница 8: ...inches 356mm Maximumhorizontalextensionofprojectionabovetheappliance 12 inches 305mm Floor top surface of carpeting tile etc 2 inches 51mm Provide adequate clearances around air openings Adequate acce...

Страница 9: ...s 0mm Ceiling 36 inches 914mm Minimum vertical clearance from a projection above the appliance shelves window sills etc 36 inches 914mm Floor top surface of carpeting tile etc 2 inches 51mm Provide ad...

Страница 10: ...eads into the wall Attention Use the following steps to properly align the upper louver and the reflector with the heat shield a Whenreplacingupperlouver besurethebottomlipofupper louver goes behind t...

Страница 11: ...f this appliance is installed directly on carpeting tile or other com bustible material other than wood flooring the appliance shall be installed on a metal or wood panel extending the full width and...

Страница 12: ...ntrol knob to lowest setting 3 Turn off all electric power to the appliance if applica ble 4 Push in gas control knob slightly and turn clockwise to OFF Do not force 5 Wait ten 10 minutes to clear out...

Страница 13: ...ect interior of casing assembly for accumulation of dust lint or spider webs If necessary clean interior of casing assembly with a vacuum cleaner or apply air pressure Do not damage any components wit...

Страница 14: ...bulb is satisfied the burner will shut OFF with the pilot flame remaining ON The SR 18T has an input of 18 000 BTUH 5 3KW H The hydraulic thermostat bulb is located at the casing assembly bottom When...

Страница 15: ...ater 3 Remove lower louver from casing assembly 2 screws 4 Remove reflector from casing assembly 2 screws 5 Remove upper louver from casing assembly 2 screws 6 If installed remove optional blower asse...

Страница 16: ...etely depressed or held in long enough b INTERLOCK latching device is operative see Lighting Instructions Page 12 Step 9 c Thermocouple not tightened into gas control tighten thermocouple d Pilot flam...

Страница 17: ...RE PACKAGE NS NOT SHOWN USE ONLY MANUFACTURED REPLACEMENT PARTS USE OF ANY OTHER PARTS COULD CAUSE INJURY OR DEATH PLEASE NOTE When ordering parts it is very important that part number and description...

Страница 18: ...16011 9 0314 Page 18 SR 10T PARTS VIEW...

Страница 19: ...16011 9 0314 Page 19 SR 18T PARTS VIEW...

Страница 20: ...anty parts All parts listed in the Parts List have a Part Number When ordering parts first obtain the Model Number and Serial Number from the name plate on your equipment Then determine the Part Numbe...

Страница 21: ...the blower housing with 1 screw provided with the optional blower 12 With the heater standing upright position the air discharge opening of the blower housing downward Place the bottom flange of the b...

Страница 22: ...r wheel will collect lint and could require periodic cleaning If the air output decreases or the noise level increases it indicates a dirty blower wheel To clean blower wheel 1 Turn OFF gas supply to...

Страница 23: ...16011 9 0314 Page 23 APPLIANCE SERVICE HISTORY Date Dealer Name Service Technician Name Service Performed Notes...

Страница 24: ...mote Controls Thermostats Accessories and Parts Should any remote control thermostat accessory or other part fail because of defective workmanship within one year from the date of purchase Empire will...

Отзывы: