7. Remove outside mounting plate with tube attached from wall.
Mark and cut the extra length of the 6 5/8” (168 mm) diameter
tube from the opposite end. Do not crimp or enlarge tube.
8. Attach the 4” (102 mm) diameter flue outlet tube onto the rigid
venting system or directly to fireplace. Ensure the 4” (102 mm)
diameter flue outlet tube is placed as far as possible onto the
rigid venting system. Mark the 4” (102 mm) diameter flue outlet
tube 2 1/2” (64 mm) beyond the vinyl siding kit or wall. See
Figure 53. Remove the 4” (102 mm) diameter flue outlet tube
from rigid venting system. When installing directly to fireplace,
tape gasket needs to be used.
9. Mark or wrap tape completely around the tubes at the marked
points to help in making a true cut. Do not crimp or enlarge
tubes.
10. From outside: Push the 6 5/8” (168 mm) diameter inlet tube/
mounting plate onto end of rigid venting system to correct posi-
tion. Fasten the outside mounting plate to the vinyl siding kit or
wall with four 10 x 1 1/2” screws. (Ensure upward slope).
11. From inside: Attach the inlet tube to the collar on the back of the
fireplace (or the rigid venting system) using three self tapping
screws.
12. Seal the 4” (102 mm) diameter flue outlet tube. Follow instruc-
tions and diagram.
See Figure 54.
13. Fasten 4” (102 mm) diameter flue outlet tube in place. Do not
“twist” the flue outlet tube into the fireplace collar (or rigid vent-
ing system). Hold the tube by the seam and push in using a
perpendicular “rocking” motion. This ensures the seam on the
tube stay intact.
14. Fasten vent cap end using three 10 x 1/2” screws to mounting
plate.
Sealing 4” (102 mm) Diameter Flue Outlet Tube
Figure 52
Figure 53
Figure 54
Note:
Tape gasket to be applied prior to installing to fireplace flue outlet tube
only. Tape gasket should not be used when mating the flue outlet tube to a rigid
venting system.
DVVK-4RE VENT KIT INSTALLATION INSTRUCTIONS (continued)
Содержание DVD32FP30N-2
Страница 21: ...31629 13 1215 Page 21 Figure 29 Figure 30 Figure 31 EXAMPLES TOP VENT RUN...
Страница 40: ...31629 13 1215 Page 40 Figure 61 MILLIVOLT STANDING PILOT WIRING DIAGRAM FP3 SERIES...
Страница 52: ...31629 13 1215 Page 52 INTERMITTENT PILOT CONTROL SYSTEM TROUBLESHOOTING FP7 SERIES...
Страница 53: ...31629 13 1215 Page 53 INTERMITTENT PILOT CONTROL SYSTEM TROUBLESHOOTING FP7 SERIES...
Страница 59: ...31629 13 1215 Page 59 DVD36FP 3 5 7 PARTS VIEW...
Страница 61: ...31629 13 1215 Page 61 DVD42FP 3 5 7 PARTS VIEW...
Страница 63: ...31629 13 1215 Page 63 DVD48FP 3 5 7 PARTS VIEW...