12821-2-0903

• Due to high temperatures, the room heater should be

located out of traffic and away from furniture and drap-
eries.

• Children and adults should be alerted to the hazards of

high surface temperature and should stay away to avoid
burns or clothing ignition.

• Young children should be carefully supervised when they

are in the same room as the room heater.

• Clothing or other flammable material should not be placed

on or near the room heater.

• Due to high surface temperatures, keep children, clothing

and furniture away.

• Keep burner and control compartment clean.

• Installation and repair should be done by a QUALIFIED

SERVICE PERSON.  The room heater should be in-
spected before use and at least annually by a qualified
service person.  More frequent cleaning may be required
due to excessive lint from carpeting, bedding material,

etc.  It is imperative that control compartments, burners
and circulating air passageways of the room heater be
kept clean.

• DO NOT put anything around the heater that will ob-

struct the flow of combustion and ventilation air.  See
clearances.

• DO keep the appliance area clear and free from combus-

tible material, gasoline and other flammable vapors and
liquids.

• DO examine venting system periodically.  Clean and

replace damaged parts.  Examinations should be made at
the start of the heating season and also in mid heating
season under average conditions.

• DO examine burners periodically.  Clean and replace

damaged parts.

• DO NOT use this heater if any part has been under water.

Immediately call a qualified service technician to inspect
the heater and to replace any part of  the control system
and any  gas control which has been under water.

THIS IS A HEATING APPLIANCE

DO NOT OPERATE THIS APPLIANCE WITHOUT FRONT PANEL INSTALLED.

IMPORTANT SAFETY INFORMATION

Attention: During operation of vented room heater the gasket for observation hole cover, observation hole cover and cover plate
for observation hole cover must be attached to combustion chamber and secured with two (2) wing nuts.

Содержание RH-25-6

Страница 1: ...iance Donottouchanyelectricalswitch donotuseanyphoneinyourbuild ing Immediatelycallyourgassupplier from a neighbor s phone Follow the gas supplier s instructions If you cannot reach your gas sup plier...

Страница 2: ...ng 7 Vent Safety Shutoff System 8 Reversible Vertical or Horizontal Diverter 8 Thermostat Operation 8 Lighting Instructions 9 Pilot Flame Characteristics 10 Main Burner Flame Characteristics 10 Mainte...

Страница 3: ...ir passageways of the room heater be kept clean DO NOT put anything around the heater that will ob struct the flow of combustion and ventilation air See clearances DO keep the appliance area clear and...

Страница 4: ...service or make adjustments in an area where the conditions are such that you may not detect the odor if there has been a leak of LP Gas Odor fade due to oxidation by rust or adsorption on walls of n...

Страница 5: ...olor tile that can discolor Floor pad is available from Empire Comfort Systems Inc Part Number DVP 1 Qualified Installing Agency Installation and replacement of gas piping gas utilization equip ment o...

Страница 6: ...Never pressure test with appliance connected control valve will sustain damage A gas valve and ground joint union should be installed in the gas line upstream of the gas control to aid in servicing I...

Страница 7: ...l be installed in a location in which the facilities for ventilation permit satisfactory combustion of gas and proper venting under normal conditions In buildings of conventional frame brick or stone...

Страница 8: ...al position to the horizontal position 1 Remove L280 vent safety switch from the draft diverter 2 Inside your yellow instruction envelope will be a 1 1 2 x 2 1 4 38mm x 51mm vent safety switch hole co...

Страница 9: ...mediately call a qualified service techni cian to inspect the appliance and to replace any part of the control system and any gas control which has been under water LIGHTING INSTRUCTIONS 1 Set thermos...

Страница 10: ...lot orifice Figure 5 MAIN BURNER FLAME CHARACTERISTICS There will be a short blue inner flame with a larger lighter blue secondary flame The burner flame may have yellow tips when hot Dust in the comb...

Страница 11: ...uple 3 Pilot flames but goes out when knob is released a Pilot flame not covering the thermocouple properly b Defective thermocouple c Defective magnet in the safety section of valve 4 Poor thermostat...

Страница 12: ...737 Burner RH 25 6 23 RH 738 Burner RH 35 6 24 R 1195 Thermocouple 36 25 R 1227 Pilot Burner with Orifice Nat 25 R 1228 Pilot Burner with Orifice LPG 26 11698 Pilot Tubing 27 R 6120 Electrode and Wir...

Страница 13: ...Page 13 12821 2 0903 PARTS VIEW...

Страница 14: ...5 6 and RH 35 1 2 4 5 6 replace casing front 5 For DV 25 1 2 SG and DV 35 1 2 SG replace heat shield and casing front Attention Wiring harness on blower is factory assembled and installed If wiring h...

Страница 15: ...rvicing WARNING Unplugging of blower accessory will not stop the heater from cycling To shut heater off 1 Turntemperaturedial orthermostattolowestsetting 2 Turnknobongascontrolto OFF depressingslightl...

Страница 16: ...E NOTES Empire Comfort Systems Inc Nine Eighteen Freeburg Ave Belleville Illinois 62220 2623 PH 1 618 233 7420 PH 1 800 851 3153 FAX 1 618 233 7097 FAX 1 800 443 8648 E MAIL info empirecomfort com WEB...