Wiring
The appliance, when installed, must be electrically grounded in
accordance with local codes or, in the absence of local codes, with
the  National Electrical Code, ANSI/NFPA 70 or Canadian
Electrical Code, CSA C22.1
, if an external electrical source is
utilized.  This appliance is equipped with a three-prong
[grounding] plug for your protection against shock hazard
and should be plugged directly into a properly grounded
three-prong receptacle.  Do not cut or remove the grounding
prong from this plug.  
For an ungrounded receptacle, an adapter,
which has two prongs and a wire for grounding, can be purchased,
plugged into the ungrounded receptacle and its wire connected to
the receptacle mounting screws.  With this wire  completing the
ground, the appliance cord plug can be plugged into the adapter
and be electrically grounded.

CAUTION: Label all wires prior to disconnection when
servicing controls. Wiring errors can cause improper and
dangerous operation. Verify proper operation after servicing.

WARNING:
Unplugging of blower accessory will not stop the heater
from cycling.  To shut heater off:
1. Turn temperature dial  or thermostat to lowest setting.
2. Turn knob on gas control to “OFF”, depressing slightly.
Do not force.

Cleaning
The blower wheel will collect lint and could require cleaning once
a year.  If the air output decreases or the noise level increases,  it
indicates a dirty wheel.  Complete removal of the wheel and
scrubbing it with a brush under flowing water is recommended.

Oiling
The blower motor has an oil hole located on each end of the motor.
Use #20 motor oil only.  It is best to oil the motor several times
during the heating season using 2 or 3 drops each time.  If the
motor fails to start and hums, it could be a tight bearing due to lack
of oil.  This may be corrected by pouring kerosene in the oil holes,
allowing to stand for a few hours and then oiling properly.

PARTS LIST

Index

Part

No.

No.

Description

1

R-2090

Motor

2

632016

Motor Cushion

 3

RH-036

Motor Support

4

642030

Blower Wheel

5

RH-710

Blower Housing Assembly

6

9120106

Fan Control Switch

7

872087

Heyco Bushing

8

DV-806

Switch Box

9

DV-807

Switch Box Cover

10

R-2091

Wire Assembly 19" (483mm)

11

8720161

Heyco Bushing

12

R-2099

Cord Set 72" (183cm)

Содержание RH-25-6

Страница 1: ...iance Donottouchanyelectricalswitch donotuseanyphoneinyourbuild ing Immediatelycallyourgassupplier from a neighbor s phone Follow the gas supplier s instructions If you cannot reach your gas sup plier...

Страница 2: ...ng 7 Vent Safety Shutoff System 8 Reversible Vertical or Horizontal Diverter 8 Thermostat Operation 8 Lighting Instructions 9 Pilot Flame Characteristics 10 Main Burner Flame Characteristics 10 Mainte...

Страница 3: ...ir passageways of the room heater be kept clean DO NOT put anything around the heater that will ob struct the flow of combustion and ventilation air See clearances DO keep the appliance area clear and...

Страница 4: ...service or make adjustments in an area where the conditions are such that you may not detect the odor if there has been a leak of LP Gas Odor fade due to oxidation by rust or adsorption on walls of n...

Страница 5: ...olor tile that can discolor Floor pad is available from Empire Comfort Systems Inc Part Number DVP 1 Qualified Installing Agency Installation and replacement of gas piping gas utilization equip ment o...

Страница 6: ...Never pressure test with appliance connected control valve will sustain damage A gas valve and ground joint union should be installed in the gas line upstream of the gas control to aid in servicing I...

Страница 7: ...l be installed in a location in which the facilities for ventilation permit satisfactory combustion of gas and proper venting under normal conditions In buildings of conventional frame brick or stone...

Страница 8: ...al position to the horizontal position 1 Remove L280 vent safety switch from the draft diverter 2 Inside your yellow instruction envelope will be a 1 1 2 x 2 1 4 38mm x 51mm vent safety switch hole co...

Страница 9: ...mediately call a qualified service techni cian to inspect the appliance and to replace any part of the control system and any gas control which has been under water LIGHTING INSTRUCTIONS 1 Set thermos...

Страница 10: ...lot orifice Figure 5 MAIN BURNER FLAME CHARACTERISTICS There will be a short blue inner flame with a larger lighter blue secondary flame The burner flame may have yellow tips when hot Dust in the comb...

Страница 11: ...uple 3 Pilot flames but goes out when knob is released a Pilot flame not covering the thermocouple properly b Defective thermocouple c Defective magnet in the safety section of valve 4 Poor thermostat...

Страница 12: ...737 Burner RH 25 6 23 RH 738 Burner RH 35 6 24 R 1195 Thermocouple 36 25 R 1227 Pilot Burner with Orifice Nat 25 R 1228 Pilot Burner with Orifice LPG 26 11698 Pilot Tubing 27 R 6120 Electrode and Wir...

Страница 13: ...Page 13 12821 2 0903 PARTS VIEW...

Страница 14: ...5 6 and RH 35 1 2 4 5 6 replace casing front 5 For DV 25 1 2 SG and DV 35 1 2 SG replace heat shield and casing front Attention Wiring harness on blower is factory assembled and installed If wiring h...

Страница 15: ...rvicing WARNING Unplugging of blower accessory will not stop the heater from cycling To shut heater off 1 Turntemperaturedial orthermostattolowestsetting 2 Turnknobongascontrolto OFF depressingslightl...

Страница 16: ...E NOTES Empire Comfort Systems Inc Nine Eighteen Freeburg Ave Belleville Illinois 62220 2623 PH 1 618 233 7420 PH 1 800 851 3153 FAX 1 618 233 7097 FAX 1 800 443 8648 E MAIL info empirecomfort com WEB...

Отзывы: