Empire Heating Systems SR-10W-1 Скачать руководство пользователя страница 31

39910-1-0919

Page 31

MASTER PARTS DISTRIBUTOR LIST

To Order Parts Under Warranty, please contact your local Empire dealer. See the dealer locator at www.empirecomfort.com. 

To provide warranty service, your dealer will need your name and address, purchase date and serial number, and the nature 

of the problem with the unit. 

To Order Parts After the Warranty Period, please contact your dealer or one of the Master Parts Distributors listed below. 

This list changes from time to time. For the current list, please click on the Master Parts button at www.empirecomfort.com.

Please note: Master Parts Distributors are independent businesses that stock the most commonly ordered Original Equipment 

repair parts for Heaters, Grills, and Fireplaces manufactured by Empire Comfort Systems Inc. 

Parts Not Under Warranty

Parts can be ordered through your Service Person, Dealer, or a Master Parts Distributor. See this page for the Master Parts Distribu-

tors list.  For best results, the 

service person or dealer

 should order parts through the distributor. Parts can be shipped directly to the 

service person/dealer

.

Warranty Parts

Warranty parts will need a proof of purchase and can be ordered by your Service Person or Dealer. Proof of purchase is 

required

 for 

warranty parts.

All parts listed in the Parts List have a Part Number. When ordering parts, first obtain the Model Number from the name plate on your 

equipment. Then determine the Part Number (

not

 the Index Number) and the Description of each part from the following appropriate 

illustration and list. Be sure to give all this information . . .

Appliance Number  

      Part Description 

Appliance Serial Number 

 

Part Number  

Type of Gas (Propane or Natural) 

Do not order bolts, screws, washers or nuts. They are standard hardware items and can be purchased at any local hardware store. 

Shipments contingent upon strikes, fires and all causes beyond our control.

HOW TO ORDER REPAIR PARTS

Dey Distributing

1401 Willow Lake Boulevard

Vadnais Heights, MN 55101

Phone: 

651-490-9191

Toll Free:

 800-397-1339

Website:

 www.deydistributing.com

Parts: Heater, Hearth and Grills

F. W. Webb Company

200 Locust Street

Hartford, CT 06114

Phone:

 860-722-2433

Toll Free: 

800-243-9360

Fax: 

860-293-0479

Toll Free Fax:

 800-274-2004

Websites: 

www.fwwebb.com & www.victormfg.com

Parts: Heater, Hearth and Grills

East Coast Energy Products

10 East Route 36

West Long Branch, NJ 07764

Phone: 

732-870-8809

Toll Free:

 800-755-8809

Fax: 

732-870-8811

Website: 

www.eastcoastenergy.com

Parts: Heater, Hearth and Grills

Star-Fire Distributors

1355 Evans Avenue

Akron, OH 44305

Phone:

 330-630-2794

Toll Free:

 800-875-6220

Fax:

 330-633-8701

Parts: Heater & Hearth and Grills

Содержание SR-10W-1

Страница 1: ...ile home where not prohibited by local codes This appliance is only for use with the type of gas indicated on the rating plate This appliance is not convertible for use with other gases This is an unv...

Страница 2: ...11 Optional Floor Stand Installation 12 Lighting Instructions 13 Main Burner Flame Characteristics 14 Important Soot Prevention Steps 15 Pilot Flame Characteristics 16 Main Burner Operation 16 Applian...

Страница 3: ...or to operating the heater Keep appliance area clear and free from combustible materials gasoline and other flammable vapors and liquids WARNING Failure to keep the primary air opening s of the burner...

Страница 4: ...hts perform service or make adjustments in an area where the conditions are such that you may not detect the odor if there has been a leak of Propane Gas Odor fade due to oxidation by rust or adsorpti...

Страница 5: ...of gas piping or b the connection installation testing repair or servicing of equipment that is experienced in such work that is familiar with all precautions required and that has complied with all t...

Страница 6: ...ing the volume of a typical area in which the SR 18W may be located and for determining if this area fits the definition of an unconfined space The maximum input of the SR 18W is 18 000 Btu per hour B...

Страница 7: ...n the gas line upstream of the gas control to aid in servicing It is required by the National Fuel Gas Code that a drip line be installed near the gas inlet This should consist of a vertical length of...

Страница 8: ...WINDOW SILL OR SHELF 24 MIN 610mm 10 MIN 254mm 12 MAX 305mm 0 0mm CLEARANCE TO REAR WALL SIDE VIEW 2 MIN 51mm FLOOR CEILING SIDE WALL WINDOW SILL OR SHELF 24 MIN 610mm 10 MIN 254mm 6 MIN 152mm 6 MIN 1...

Страница 9: ...ust be maintained Left side 6 inches 152mm Right side 6 inches 152mm Do not install in alcove or closet Rear wall 0 inches 0mm Ceiling 36 inches 914mm Minimum vertical clearance from a projection abov...

Страница 10: ...9 10 11 and 12 for measurements in order to locate 4 mounting holes on wall Figures 9 10 11 and 12 are the front views of the heaters 1 Remove lower louver from casing assembly 2 screws 2 Remove refle...

Страница 11: ...10 x 1 25mm screws provided into the plastic expansion anchors Do not completely tighten screwheads to the plastic expansion anchors leave a 1 8 3mm gap between screwheads and plastic expansion ancho...

Страница 12: ...Attach floor stand to heater with 4 screws provided with floor stand 3 Connect the gas line Floor stand can not be used in a bathroom or bedroom installation SR 6W must be wall mounted in a bathroom...

Страница 13: ...d pilot the pilot is at tached at the bottom of the burner assembly 6 Turn manual gas control knob counterclockwise to PILOT 7 Push in manual gas con trol knob all the way and hold in Repeatedly push...

Страница 14: ...inside the casing assembly and main burner assembly Use the following procedure to inspect the casing assembly and main burner as sembly 1 Turn OFF gas supply to the heater 2 Turn OFF electric supply...

Страница 15: ...u have pets or excessive dust more frequent cleaning may be necessary See main burner flame characteristics section in this manual 1 Ensure burner venturi and air shutter are free of dirt lint animal...

Страница 16: ...N it will continue to operate until the owner manually turns the main burner OFF Description of Manual Gas Control Knob OFF position PILOT position SR 6W Position 1 Will have one plaque in operation t...

Страница 17: ...electrical supply to the heater if optional blower is installed in heater 3 Remove lower louver from casing assembly 2 screws 4 Remove reflector from casing assembly 2 screws 5 Disconnect inlet suppl...

Страница 18: ...ntrol knob in pilot position not completely depressed or held in long enough b Thermocouple not tightened into gas control tighten thermocouple c Pilot flame not surrounding thermocouple clean pilot s...

Страница 19: ...39910 1 0919 Page 19 This page intentionally left blank...

Страница 20: ...AS VALVE TO PILOT 13 SR 112 VALVE BRACKET 14 R 2277 GAS VALVE COPRECI 15 SR 139 TUBING GAS VALVE TO BURNER 16 SR 221 TUBING INLET REGULATOR TO GAS VALVE 17 R 5097 INLET REGULATOR NATURAL 17 R 5098 INL...

Страница 21: ...39910 1 0919 Page 21 SR 6W parts View...

Страница 22: ...GAS VALVE TO PILOT 13 SR 112 VALVE BRACKET 14 R 2277 GAS VALVE COPRECI 15 SR 139 TUBING GAS VALVE TO BURNER 16 SR 221 TUBING INLET REGULATOR TO GAS VALVE 17 R 5097 INLET REGULATOR NATURAL 17 R 5098 IN...

Страница 23: ...39910 1 0919 Page 23 SR 10W parts View...

Страница 24: ...18 R 2498 MAIN BURNER ORIFICE PROPANE 3 REQUIRED 19 R 2330 BURNER 20 SR 082 TUBING GAS VALVE TO BURNER TWO 21 SR 217 TUBING INLET REGULATOR TO GAS VALVE 22 10753 INLET REGULATOR BRACKET 23 R 5097 INL...

Страница 25: ...39910 1 0919 Page 25 SR 18W parts View...

Страница 26: ...HOLDER 5 REQUIRED 20 R 2315 MAIN BURNER ORIFICE NATURAL 5 REQUIRED 20 R 2498 MAIN BURNER ORIFICE PROPANE 5 REQUIRED 21 R 2329 BURNER 22 10753 INLET REGULATOR BRACKET 23 R 5097 INLET REGULATOR NATURAL...

Страница 27: ...39910 1 0919 Page 27 SR 30W parts View...

Страница 28: ...ot wire on motor wire harness OPTIONAL BLOWERS SRB 18W and SRB 30W for Unvented Room Heaters SR 18W and SR 30W HEAT SHIELD GROUND WIRE SCREW REFLECTOR AND LOUVERS ARE REMOVED FROM CASING ASSEMBLY ON O...

Страница 29: ...met with brass bushing or black rubber grommet with brass bushing onto end of blower wheel shaft Attention The red rubber grommet with brass bushing or the black rubber grommet with brass bushing must...

Страница 30: ...SING 2 R 2522 ON OFF SWITCH 3 R 2395 WIRE ASSEMBLY 4 R1468 BUSHING HEYCO SR5KN4 5 R2099 CORD SET ASSEMBLY 6 39873 BLOWER PAN SR 18W 6 39874 BLOWER PAN SR 30W 7 R1449 RUBBER GROMMET 4 REQUIRED 8 R1454...

Страница 31: ...purchase is required for warranty parts All parts listed in the Parts List have a Part Number When ordering parts first obtain the Model Number from the name plate on your equipment Then determine the...

Страница 32: ...ppliance must be installed by a qualified installer and operated in accordance with the instructions furnished with the appliance A bill of sale cancelled check or payment record should be kept to ver...

Отзывы: