IMPORTANT SOOT PREVENTION STEPS
IMPORTANT NOTICE
INSTALLER - SERVICE PERSON - HOMEOWNER
SOOT MAY BE CREATED IF THE FOLLOWING DIRECTIONS ARE NOT FOLLOWED
A vent-free heater draws room air to support combustion. Lightweight
particles suspended in the air – including dust, carpet fibers, candle
or tobacco smoke, and pet hair – will be drawn toward the heater.
These can lead to soot build-up on the heater, and even walls of
the room. To prevent malfunctions and sooting, have your dealer
inspect and clean each year – before the heating season. If you
have pets or excessive dust, more frequent cleaning may be
necessary. See main burner flame characteristics section in this
manual.
1. Ensure burner, venturi, and air shutter are free of dirt, lint,
animal hair (i.e. cat and dog) or anything that may block the
needed air flow.
2. Do not use scented air fresheners or candles while the
heater is in operation. They produce residue which may
cause soot.
3. Annual inspection and cleaning by your dealer or a qualified
service technician is recommended to prevent malfunction
and/or sooting.
WARNING
Do not allow fans to blow directly into or at the fireplace.
Avoid any drafts that alter burner flame patterns. Avoid any
drafts that alter burner flame patterns. Pay particular atten
-
tion to ceiling fans and exhaust fans.