Empire Heating Systems SR-10W-1 Скачать руководство пользователя страница 28

39910-1-0919

Page 28

INSTALLING OPTIONAL BLOWER SRB-18W OR SRB-30W

If heater is installed onto the wall, in order to install the optional 

blower, the heater must be removed from the wall. If heater is in-

stalled on optional floor stand there is adequate access area avail

-

able to install the optional blower.

1.  Turn “OFF” gas supply to the heater.

2.  Remove lower louver from casing assembly (2 screws).

3.  Remove reflector from casing assembly (2 screws).

4.  Remove upper louver from casing assembly (2 screws).

5.  Remove on/off switch knockout from the casing assembly 

top.

6.  Insert the on/off switch wires through the casing assembly 

top. The on/off switch wires will enter the top portion of the 

casing assembly. Snap on/off switch into the casing assembly 

top.

7.  Route cord set through 9/16” (14mm) diameter hole on casing 

assembly back. Insert approximately 3” (76mm) of cord set 

into casing assembly back.

8.  When you are facing the front of the heater, position the 

optional blower assembly onto the top heat shield of the 

heater. The motor wire harness should be facing into the top, 

right portion of the heater.

9.  Attach (1) pin terminal from black (hot) wire, smooth insulation 

on cord set to (1) socket terminal from the on/off switch.

10.  Attach  (1)  pin  terminal  from  black  (neutral)  wire,  ribbed  

insulation  on  cord  set  to  (1)  socket  terminal  from  white 

(neutral) wire on motor wire harness.

11.  Attach  (1)  pin  terminal  from  the  on/off  switch  to  (1)  socket 

terminal from black (hot) wire on motor wire harness.

OPTIONAL BLOWERS

SRB-18W and SRB-30W

for Unvented Room Heaters SR-18W and SR-30W

HEAT SHIELD

GROUND

WIRE

SCREW

REFLEC

TOR

AND

LOUVER

S ARE

REMOVED

FROM

CASING

ASSEMBL

Y

ON/OFF

SWITCH

CORD

SET

HOLE

IN

CASING

BAC

K

12.  Attach the green ground wire from the motor wire harness and 

the green ground wire from the cord set to the bottom right 

side of the blower housing with (1) screw provided with the 

optional blower.

13.  With the heater standing upright, position the air discharge 

opening of the blower housing downward. Place the bottom 

flange of the blower housing over the top edge of the top heat 

shield. Insert the blower housing into the top portion of the 

heater by pivoting the blower housing upward 90°. Attach 

the  blower  housing  to  the  casing  assembly  with  (4)  screws 

provided with the optional blower.

14.  Grasp cord set at casing assembly back and pull excess cord 

set through casing assembly back. Secure cord set in casing 

assembly back with the strain relief provided with the optional 

blower.

15.  Installation of optional blower is completed.

16.  If heater was removed from the wall, in order to install optional 

blower, check for gas leaks at all gas connections before lower 

louver is replaced onto casing assembly.

Attention! 

After optional blower has been installed use the 

following steps to properly align the upper louver and the reflector 

with the heat shield.

A.  When replacing upper louver, be sure the bottom lip of upper 

louver goes behind the heat shield.

B.  When replacing reflector, be sure the top lip of reflector goes 

in front of the heat shield.

SR-30 Shown

OPTIONAL BLOWER INSTALLATION INSTRUCTIONS

Содержание SR-10W-1

Страница 1: ...ile home where not prohibited by local codes This appliance is only for use with the type of gas indicated on the rating plate This appliance is not convertible for use with other gases This is an unv...

Страница 2: ...11 Optional Floor Stand Installation 12 Lighting Instructions 13 Main Burner Flame Characteristics 14 Important Soot Prevention Steps 15 Pilot Flame Characteristics 16 Main Burner Operation 16 Applian...

Страница 3: ...or to operating the heater Keep appliance area clear and free from combustible materials gasoline and other flammable vapors and liquids WARNING Failure to keep the primary air opening s of the burner...

Страница 4: ...hts perform service or make adjustments in an area where the conditions are such that you may not detect the odor if there has been a leak of Propane Gas Odor fade due to oxidation by rust or adsorpti...

Страница 5: ...of gas piping or b the connection installation testing repair or servicing of equipment that is experienced in such work that is familiar with all precautions required and that has complied with all t...

Страница 6: ...ing the volume of a typical area in which the SR 18W may be located and for determining if this area fits the definition of an unconfined space The maximum input of the SR 18W is 18 000 Btu per hour B...

Страница 7: ...n the gas line upstream of the gas control to aid in servicing It is required by the National Fuel Gas Code that a drip line be installed near the gas inlet This should consist of a vertical length of...

Страница 8: ...WINDOW SILL OR SHELF 24 MIN 610mm 10 MIN 254mm 12 MAX 305mm 0 0mm CLEARANCE TO REAR WALL SIDE VIEW 2 MIN 51mm FLOOR CEILING SIDE WALL WINDOW SILL OR SHELF 24 MIN 610mm 10 MIN 254mm 6 MIN 152mm 6 MIN 1...

Страница 9: ...ust be maintained Left side 6 inches 152mm Right side 6 inches 152mm Do not install in alcove or closet Rear wall 0 inches 0mm Ceiling 36 inches 914mm Minimum vertical clearance from a projection abov...

Страница 10: ...9 10 11 and 12 for measurements in order to locate 4 mounting holes on wall Figures 9 10 11 and 12 are the front views of the heaters 1 Remove lower louver from casing assembly 2 screws 2 Remove refle...

Страница 11: ...10 x 1 25mm screws provided into the plastic expansion anchors Do not completely tighten screwheads to the plastic expansion anchors leave a 1 8 3mm gap between screwheads and plastic expansion ancho...

Страница 12: ...Attach floor stand to heater with 4 screws provided with floor stand 3 Connect the gas line Floor stand can not be used in a bathroom or bedroom installation SR 6W must be wall mounted in a bathroom...

Страница 13: ...d pilot the pilot is at tached at the bottom of the burner assembly 6 Turn manual gas control knob counterclockwise to PILOT 7 Push in manual gas con trol knob all the way and hold in Repeatedly push...

Страница 14: ...inside the casing assembly and main burner assembly Use the following procedure to inspect the casing assembly and main burner as sembly 1 Turn OFF gas supply to the heater 2 Turn OFF electric supply...

Страница 15: ...u have pets or excessive dust more frequent cleaning may be necessary See main burner flame characteristics section in this manual 1 Ensure burner venturi and air shutter are free of dirt lint animal...

Страница 16: ...N it will continue to operate until the owner manually turns the main burner OFF Description of Manual Gas Control Knob OFF position PILOT position SR 6W Position 1 Will have one plaque in operation t...

Страница 17: ...electrical supply to the heater if optional blower is installed in heater 3 Remove lower louver from casing assembly 2 screws 4 Remove reflector from casing assembly 2 screws 5 Disconnect inlet suppl...

Страница 18: ...ntrol knob in pilot position not completely depressed or held in long enough b Thermocouple not tightened into gas control tighten thermocouple c Pilot flame not surrounding thermocouple clean pilot s...

Страница 19: ...39910 1 0919 Page 19 This page intentionally left blank...

Страница 20: ...AS VALVE TO PILOT 13 SR 112 VALVE BRACKET 14 R 2277 GAS VALVE COPRECI 15 SR 139 TUBING GAS VALVE TO BURNER 16 SR 221 TUBING INLET REGULATOR TO GAS VALVE 17 R 5097 INLET REGULATOR NATURAL 17 R 5098 INL...

Страница 21: ...39910 1 0919 Page 21 SR 6W parts View...

Страница 22: ...GAS VALVE TO PILOT 13 SR 112 VALVE BRACKET 14 R 2277 GAS VALVE COPRECI 15 SR 139 TUBING GAS VALVE TO BURNER 16 SR 221 TUBING INLET REGULATOR TO GAS VALVE 17 R 5097 INLET REGULATOR NATURAL 17 R 5098 IN...

Страница 23: ...39910 1 0919 Page 23 SR 10W parts View...

Страница 24: ...18 R 2498 MAIN BURNER ORIFICE PROPANE 3 REQUIRED 19 R 2330 BURNER 20 SR 082 TUBING GAS VALVE TO BURNER TWO 21 SR 217 TUBING INLET REGULATOR TO GAS VALVE 22 10753 INLET REGULATOR BRACKET 23 R 5097 INL...

Страница 25: ...39910 1 0919 Page 25 SR 18W parts View...

Страница 26: ...HOLDER 5 REQUIRED 20 R 2315 MAIN BURNER ORIFICE NATURAL 5 REQUIRED 20 R 2498 MAIN BURNER ORIFICE PROPANE 5 REQUIRED 21 R 2329 BURNER 22 10753 INLET REGULATOR BRACKET 23 R 5097 INLET REGULATOR NATURAL...

Страница 27: ...39910 1 0919 Page 27 SR 30W parts View...

Страница 28: ...ot wire on motor wire harness OPTIONAL BLOWERS SRB 18W and SRB 30W for Unvented Room Heaters SR 18W and SR 30W HEAT SHIELD GROUND WIRE SCREW REFLECTOR AND LOUVERS ARE REMOVED FROM CASING ASSEMBLY ON O...

Страница 29: ...met with brass bushing or black rubber grommet with brass bushing onto end of blower wheel shaft Attention The red rubber grommet with brass bushing or the black rubber grommet with brass bushing must...

Страница 30: ...SING 2 R 2522 ON OFF SWITCH 3 R 2395 WIRE ASSEMBLY 4 R1468 BUSHING HEYCO SR5KN4 5 R2099 CORD SET ASSEMBLY 6 39873 BLOWER PAN SR 18W 6 39874 BLOWER PAN SR 30W 7 R1449 RUBBER GROMMET 4 REQUIRED 8 R1454...

Страница 31: ...purchase is required for warranty parts All parts listed in the Parts List have a Part Number When ordering parts first obtain the Model Number from the name plate on your equipment Then determine the...

Страница 32: ...ppliance must be installed by a qualified installer and operated in accordance with the instructions furnished with the appliance A bill of sale cancelled check or payment record should be kept to ver...