OPTIONAL BLOWER INSTALLATION INSTRUCTIONS (

CoNT’D)

Blower Wheel

The blower wheel will collect lint and could require periodic 

cleaning. If the air output decreases or the noise level in-

creases, it indicates a dirty blower wheel. 

To clean blower wheel:

1.  Turn OFF gas supply to the heater.

2.  Turn OFF electrical supply to the heater.

3.  Remove  lower  louver  from  casing  assembly  (2 

screws).

4.  Remove reflector from casing assembly (2 screws).

5.  Remove  upper  louver  from  casing  assembly  (2 

screws).

6.  Clean blower wheel with a vacuum cleaner.

7.  As parts are being replaced in reverse order, check for 

gas leaks at all gas connections before lower louver is 

replaced onto casing assembly.

WARNING

Unplugging of blower accessory will not stop the heater 

from cycling. To turn off gas to the unvented heater: 

Push in gas control knob slightly and turn clockwise 

to “OFF.” Do not force.

Excessive Blower Wheel Noise

ATTENTION! If your blower assembly develops a squeal, hum or 

grinding noise, it indicates dirt or debris on shaft of blower wheel. 

Use the following steps to clean shaft of blower wheel.

1.  Remove red rubber grommet with brass bushing or black 

rubber grommet with brass bushing from end of blower wheel 

shaft opposite motor.

2.  Clean blower wheel shaft with cotton cloth.

3.  Place 1 or 2 drops of all purpose oil on END of blower wheel 

shaft.

4.  Replace red rubber grommet with brass bushing or black 

rubber grommet with brass bushing onto end of blower wheel 

shaft.

 

Attention: The red rubber grommet with brass bushing or the 

black rubber grommet with brass bushing must “snap-back” 

into position.

5.  Cleaning of blower wheel shaft is completed.

Wiring

The appliance, when installed, must be electrically grounded 

in accordance with local codes or, in the absence of local 

codes, with the National Electrical Code, ANSI/NFPA 70, 

if an external electrical source is utilized. This appliance is 

equipped with a three-prong [grounding] plug for your protec

-

tion against shock hazard and should be plugged directly into 

a properly grounded three-prong receptacle. Do not cut or 

remove the grounding prong from this plug. For an ungrounded 

receptacle, an adapter, which has two prongs and a wire for 

grounding, can be purchased, plugged into the ungrounded 

receptacle and its wire connected to the receptacle mounting 

screw. With this wire completing the ground, the appliance 

cord plug can be plugged into the adapter and be electrically 

grounded. 

CAUTION

Label all wires prior to disconnection when servicing 

controls. Wiring errors can cause improper and danger-

ous operation. Verify proper operation after servicing. 

Blower Motor

The blower motor does not have oiling holes. Do not attempt 

to oil the blower motor.

If any of the original wire as supplied with the appliance must 

be replaced, it must be replaced with type 125°C wire or its 

equivalent.

WHITE

MOTOR

BLACK

BLACK

BLACK

ON/OFF SWITCH

GREEN GROUND WIRE

NEUTRAL

HOT

SPT-3 CORD

BLACK

SMOOTH

BLACK

RIBBED

Содержание SR-10W-1

Страница 1: ...ile home where not prohibited by local codes This appliance is only for use with the type of gas indicated on the rating plate This appliance is not convertible for use with other gases This is an unv...

Страница 2: ...11 Optional Floor Stand Installation 12 Lighting Instructions 13 Main Burner Flame Characteristics 14 Important Soot Prevention Steps 15 Pilot Flame Characteristics 16 Main Burner Operation 16 Applian...

Страница 3: ...or to operating the heater Keep appliance area clear and free from combustible materials gasoline and other flammable vapors and liquids WARNING Failure to keep the primary air opening s of the burner...

Страница 4: ...hts perform service or make adjustments in an area where the conditions are such that you may not detect the odor if there has been a leak of Propane Gas Odor fade due to oxidation by rust or adsorpti...

Страница 5: ...of gas piping or b the connection installation testing repair or servicing of equipment that is experienced in such work that is familiar with all precautions required and that has complied with all t...

Страница 6: ...ing the volume of a typical area in which the SR 18W may be located and for determining if this area fits the definition of an unconfined space The maximum input of the SR 18W is 18 000 Btu per hour B...

Страница 7: ...n the gas line upstream of the gas control to aid in servicing It is required by the National Fuel Gas Code that a drip line be installed near the gas inlet This should consist of a vertical length of...

Страница 8: ...WINDOW SILL OR SHELF 24 MIN 610mm 10 MIN 254mm 12 MAX 305mm 0 0mm CLEARANCE TO REAR WALL SIDE VIEW 2 MIN 51mm FLOOR CEILING SIDE WALL WINDOW SILL OR SHELF 24 MIN 610mm 10 MIN 254mm 6 MIN 152mm 6 MIN 1...

Страница 9: ...ust be maintained Left side 6 inches 152mm Right side 6 inches 152mm Do not install in alcove or closet Rear wall 0 inches 0mm Ceiling 36 inches 914mm Minimum vertical clearance from a projection abov...

Страница 10: ...9 10 11 and 12 for measurements in order to locate 4 mounting holes on wall Figures 9 10 11 and 12 are the front views of the heaters 1 Remove lower louver from casing assembly 2 screws 2 Remove refle...

Страница 11: ...10 x 1 25mm screws provided into the plastic expansion anchors Do not completely tighten screwheads to the plastic expansion anchors leave a 1 8 3mm gap between screwheads and plastic expansion ancho...

Страница 12: ...Attach floor stand to heater with 4 screws provided with floor stand 3 Connect the gas line Floor stand can not be used in a bathroom or bedroom installation SR 6W must be wall mounted in a bathroom...

Страница 13: ...d pilot the pilot is at tached at the bottom of the burner assembly 6 Turn manual gas control knob counterclockwise to PILOT 7 Push in manual gas con trol knob all the way and hold in Repeatedly push...

Страница 14: ...inside the casing assembly and main burner assembly Use the following procedure to inspect the casing assembly and main burner as sembly 1 Turn OFF gas supply to the heater 2 Turn OFF electric supply...

Страница 15: ...u have pets or excessive dust more frequent cleaning may be necessary See main burner flame characteristics section in this manual 1 Ensure burner venturi and air shutter are free of dirt lint animal...

Страница 16: ...N it will continue to operate until the owner manually turns the main burner OFF Description of Manual Gas Control Knob OFF position PILOT position SR 6W Position 1 Will have one plaque in operation t...

Страница 17: ...electrical supply to the heater if optional blower is installed in heater 3 Remove lower louver from casing assembly 2 screws 4 Remove reflector from casing assembly 2 screws 5 Disconnect inlet suppl...

Страница 18: ...ntrol knob in pilot position not completely depressed or held in long enough b Thermocouple not tightened into gas control tighten thermocouple c Pilot flame not surrounding thermocouple clean pilot s...

Страница 19: ...39910 1 0919 Page 19 This page intentionally left blank...

Страница 20: ...AS VALVE TO PILOT 13 SR 112 VALVE BRACKET 14 R 2277 GAS VALVE COPRECI 15 SR 139 TUBING GAS VALVE TO BURNER 16 SR 221 TUBING INLET REGULATOR TO GAS VALVE 17 R 5097 INLET REGULATOR NATURAL 17 R 5098 INL...

Страница 21: ...39910 1 0919 Page 21 SR 6W parts View...

Страница 22: ...GAS VALVE TO PILOT 13 SR 112 VALVE BRACKET 14 R 2277 GAS VALVE COPRECI 15 SR 139 TUBING GAS VALVE TO BURNER 16 SR 221 TUBING INLET REGULATOR TO GAS VALVE 17 R 5097 INLET REGULATOR NATURAL 17 R 5098 IN...

Страница 23: ...39910 1 0919 Page 23 SR 10W parts View...

Страница 24: ...18 R 2498 MAIN BURNER ORIFICE PROPANE 3 REQUIRED 19 R 2330 BURNER 20 SR 082 TUBING GAS VALVE TO BURNER TWO 21 SR 217 TUBING INLET REGULATOR TO GAS VALVE 22 10753 INLET REGULATOR BRACKET 23 R 5097 INL...

Страница 25: ...39910 1 0919 Page 25 SR 18W parts View...

Страница 26: ...HOLDER 5 REQUIRED 20 R 2315 MAIN BURNER ORIFICE NATURAL 5 REQUIRED 20 R 2498 MAIN BURNER ORIFICE PROPANE 5 REQUIRED 21 R 2329 BURNER 22 10753 INLET REGULATOR BRACKET 23 R 5097 INLET REGULATOR NATURAL...

Страница 27: ...39910 1 0919 Page 27 SR 30W parts View...

Страница 28: ...ot wire on motor wire harness OPTIONAL BLOWERS SRB 18W and SRB 30W for Unvented Room Heaters SR 18W and SR 30W HEAT SHIELD GROUND WIRE SCREW REFLECTOR AND LOUVERS ARE REMOVED FROM CASING ASSEMBLY ON O...

Страница 29: ...met with brass bushing or black rubber grommet with brass bushing onto end of blower wheel shaft Attention The red rubber grommet with brass bushing or the black rubber grommet with brass bushing must...

Страница 30: ...SING 2 R 2522 ON OFF SWITCH 3 R 2395 WIRE ASSEMBLY 4 R1468 BUSHING HEYCO SR5KN4 5 R2099 CORD SET ASSEMBLY 6 39873 BLOWER PAN SR 18W 6 39874 BLOWER PAN SR 30W 7 R1449 RUBBER GROMMET 4 REQUIRED 8 R1454...

Страница 31: ...purchase is required for warranty parts All parts listed in the Parts List have a Part Number When ordering parts first obtain the Model Number from the name plate on your equipment Then determine the...

Страница 32: ...ppliance must be installed by a qualified installer and operated in accordance with the instructions furnished with the appliance A bill of sale cancelled check or payment record should be kept to ver...

Отзывы: