31722-1-1213
Page 29
check the following items during installation prior to lighting
the multisided burner:
•
Check air shutter for correct setting.
o NAT gas
- The air shutter setting must be 1/4" (6.4mm)
for VFSU(R,E)18.
o LP gas
- The air shutter setting must be Full Open for
VFSU(R,E)(18,24,30).
AIR SHUTTER FULL OPEN
NOTICE
:
Orifice shield removed for photo clarity.
•
Check all carryover ports for blockage from the ceramic media
o If there is blockage, use a small pointed tool to move the
ceramic media away from the carryover port.
•
For best results when lighting the burner, have the adjustable
flame knob to the HI position, then adjust to a lower setting
after the burner has ignited.
•
When first lighting the pilot on the burner, it takes approximately
60 to 75 seconds to fully heat and energize the thermopile.
Once the thermopile is energized, turn on the gas valve and
light the burner.