Over time, the rockwool will break down and new rockwool will
need to be placed to recreate the original glowing embers effect.
Remove all old rockwool from the appliance and apply new rock as
described in this section or the log manual.
NOTICE
: Only the rockwool supplied with this unit or ordered in
accordance with the Parts List on pages 32 and 34 should be used
on this burner. See the Parts List on pages 32 and 34 to order
replacement rockwool.
Placing Lava rock in Front of Burner on Fireplace Floor
Spread lava rocks on fireplace floor in front and sides of the burner
pan. Lava rocks can be placed around the VFSUE control module.
The lava rocks are for decorative effect and are not required for
fireplace operation.
ATTeNTION:
DO NOT PLACE LAVA ROCKS ON BURNER,
LOGS OR ROCKWOOL. THE LAVA ROCKS SHOULD ONLY
BE PLACED ON THE FIREPLACE FLOOR.
Placement of the glowing embers (rockwool) is very individual
and light coverage will provide your best effects. We recommend
separation of the rockwool by hand and make your coverage as
light and fluffy as possible.
Place just enough rockwool on the burner to obtain the glow and
a gold, yellow flame.
Do not place rockwool over large ports in middle portion of
burner.
rockwool should not be placed in the area of the pilot as-
sembly.
Application of excess rockwool may adversely affect performance
of the heater.
wArNING
All previously applied rockwool must be removed prior to
reapplication.
PLAceMeNT OF GLOwING eMBerS AND LAVA rOcK
OPerATION INSTrucTIONS/FLAMe APPeArANce
Flames from the pilot (rear right back side of the pan burner) as
well as the main flame should be visually checked as the log set
is installed.
In normal operation at full rate after 10 to 15 minutes, the flame
appearance should be sets of yellow flames.
NOTICE
:
All flames will be random by design, flame height will go
up and down.
Glowing embers (rockwool) can cover the pan burner's round ports
in between the front and middle logs, but very little is necessary to
cover this area. Excess ember material causes the yellow flame to
become orange and stringy. Apply just enough to obtain slow glow
and a gold yellow flame.
Avoid any drafts that alter burner flame patterns. Do not allow fans to
blow directly into fireplace. Do not place a blower inside the burner
area of the firebox. Ceiling fans may create drafts that alter flame
patterns. Sooting and improper burning will result.
During manufacturing, fabricating and shipping, various components
of this appliance are treated with certain oils, films or bonding agents.
These chemicals are not harmful, but may produce annoying smoke
and smells as they are burned off during the initial operation of the
appliance, possibly causing headaches or eye or lung irritation. This
is a normal and temporary occurrence.
The initial break-in operation should last 2-3 hours with the burner
at the highest setting. Provide maximum ventilation by opening
windows or doors to allow odors to dissipate. Any odors remaining
after this initial break-in will be slight and will disappear with
continued use.
VFSur - Figure 14
VFSue - Figure 14
Note For Burner Port Ignition:
Due to the size of the burner, there may be a small delay before
all burner ports ignite.