background image

32707-8-0714

Page 41

IP TROUBLESHOOTING

2

Main burner lights

when the pilot only

should light.

Pilot holds the flame?.

Main burner ignites?

Main burner remains

ON

1.

Replace DFC board.

2.

Replace the gas valve.

1.

Verify the pilot flame fully engulfs the tip of the sense electrode. If not replace the pilot

assembly.

2.

Replace the pilot assembly.

3.

Carefully clean the electrical connections of the sense cable, and the DFC board sense

cable connection.

4.

Replace the sense cable, or the cable-sense electrode assembly, or the pilot assembly.

5.

Verify the pilot is properly grounded.

6.

Replace the pilot orifice with a new orifice of correct size, and type, or replace the pilot

assembly.

7.

If pilot flow adjuster screw is not sealed, correct it.

1.

Verify the electrical connections’ integrity and make sure they are in accordance with the

relevant system wiring diagram. If necessary replace the wire harness.

2.

Check if the optional remote transmitter is in “thermostat” or “on” mode and verifyt there is a

call for heat (f using a thermostat remote). Adjust the setting for heat.

3.

Verify that the pilot hood is properly fitted and a pilot flame is directed to properly ignite the

main appliance burner.

4.

Replace the main burner orifice with a new orifice of correct size and type, or replace the

pilot assembly. Under all circumstances follow the service instructions.

5.

Remove the provided wiring harnesses from EV2 of gas valve (red base), and verify voltage

at ignition between the EV1 terminal and the ground connection on the valve body.
5.1

If the voltage is greater than 0 then Replace Valve.

5.2

Or Replace DFC.

6.

Check the pressure at the outlet pressure test point out according to the manufacturer’s

instruction. If not in accordance, replace the gas valve.

1.

Verify the electrical connections’ integrity and make sure they are in accordance with the

relevant system wiring diagram. If necessary replace the wire harness.

2.

Check the pressure at the outlet pressure test point out according the manufacturer’s

instruction. If not in accordance replace the gas valve.

3.

With the system in the OFF position, connect the voltmeter between the EV2 terminal

(green base) on the valve, and the ground on the valve body.
Turn the system ON, let pilot light, and observe the following voltage sequence: once the pilot
flame is proved, the voltage on EV2 should spike to approx. 5 VdC for approx. 2 sec and then
drop to approx. 0.6 VdC continuously.
3.1

If the sequence is respected, replace the gas valve.

3.2

If the sequence is not respected, replace the DFC board.

YES

YES

YES

NO

NO

NO

NO

Main burner

modulates

properly?

1.

Replace the main burner orifice with a new orifice of correct size (partial blockage possible).

Verify that the main burner flame modulates. If it does not modulate replace the gas valve.

2.

Verify that the gas valve outlet pressure limits are in accordance with the manufacturer

specifications. If not replace the gas valve.

3.

Verify the flame changes while rotating the HI/LO knob on the front of the gas valve. If there

is no change replace the gas valve.

FOR MANUAL HI/LO VERSION

Содержание VFLL38FP

Страница 1: ...injury or loss of life Installer Leave this manual with the appliance Consumer Retain this manual for future reference This appliance may be installed in an aftermarket permanently located manufactur...

Страница 2: ...ENTILATION AIR 16 17 COMBUSTIBLE MATERIALS 18 CLEANING AND SERVICING 18 19 MAINTENANCE 19 DECORATIVE ACCESSORY INSTALLATION 20 21 MILLIVOLT CONTROL VALVE LIGHTING INSTRUCTIONS 22 IP LIGHTING INSTRUCTI...

Страница 3: ...to avoid potential problems with sooting Sooting resulting from improper installation or operation can settle on surfaces outside the fireplace See instructions for proper installation WARNING Do not...

Страница 4: ...as can adsorb or absorb onto or into walls masonry and other materials and fabrics in a room That will take some of the odorant out of the gas reducing its odor intensity LP Gas may stratify in a clos...

Страница 5: ...e log and create a sooting situation WARNING Do not allow fans to blow directly into the fireplace Avoid any drafts that alter burner flame patterns Candles Avoid the use of scented or decorative cand...

Страница 6: ...ze Well Head Gas Installations Some natural gas utilities use well head gas This may affect the Btuoutputoftheunit Contactthegascompanyfortheheatingvalue Contact the manufacturer or your gas company b...

Страница 7: ...ss Droplets 1 Ruby Clear One kit per one square foot DG1TZC DG1TZC Decorative Glass Droplets 1 Topaz Clear One kit per one square foot DG1BKP DG1BKP Decorative Glass Crushed 1 4 Black One kit per one...

Страница 8: ...t the fireplace and components have not been dam aged during shipping 7 Set fireplace in a location near to its final installation location In planning the installation for the fireplace determine whe...

Страница 9: ...bus tible board around the opening The other hole is for mounting the non combustible board to the fireplace face top side and bottom See Figures 4 and 6 Figure 4 5 On the top and bottom of each side...

Страница 10: ...r VFLL 38 48 FP30L series millivolt operated system Wiring is only needed if adding the LK5 Accent Light accessory Follow the wiring instructions included with the LK5 to connect this optional accesso...

Страница 11: ...re to the opposite side Secure the incoming ground wire under the green ground screw provided on the receptacle Figure 14 Figure 15 5 If only installing the LK5 Accent Light kit then remove the 7 8 di...

Страница 12: ...efore it is not necessary to provide a 1 8 test point up stream of the control When using copper or flex connector use only approved fittings Theapplianceandit sindividualshutoffvalvemustbedisconnecte...

Страница 13: ...rations Installing a television above a fireplace has become increasingly popular however the area above any fireplace gets hot and most TV manufacturers recommend against placing their products near...

Страница 14: ...the unit Attach these pieces to the face of the unit with high tempera ture silicone adhesive or with screws If putting screws into the face of the unit avoid the area around the outer glass See Figur...

Страница 15: ...ling in Corner Built In Rough Opening for Elevated Installation Built In Figure 22 Figure 23 Figure 24 FIREPLACE INSTALLATION TABLE 1 MINIMUM DIMENSIONS in inches FOR FIGURES 22 23 24 A B C D E F VFLL...

Страница 16: ...or less with openings gasketed or sealed and b Weather stripping has been added on openable windows and doors and c Caulking or sealants are applied to areas such as joints around window and door fra...

Страница 17: ...shall have a minimum free area of one square inch per 1 000 BTUH of the total input rating of the gas equipment in the confined space Figure 25 WARNING Rework worksheet adding the space of the adjoin...

Страница 18: ...emove lint or particles with vacuum or brush Failure to keep air intake hole clean will result in sooting and poor combustion Inspect and clean all burner ports Inspect ODS pilot for operation and acc...

Страница 19: ...receiver are located under the heat shield 5 Replace the four AA batteries in each 6 Replace the items removed in steps 1 through 4 MAINTENANCE CLEANING AND SERVICING Cleaning and Pilot Maintenance O...

Страница 20: ...be more than a single layer CAUTION Never place media materials on or next to the burner The Decorative Glass options are available in various colors and package sizes Choose the size appropriate for...

Страница 21: ...lets 1 2 inch glass drops 1 inch or ceramic fiber rocks and pebbles Mix colors and glass types but do not exceed the recommended amount of decorative media CAUTION Glass or rocks must not be placed ar...

Страница 22: ...power to the appliance if applicable 5 Push in gas control knob slightly and turn clockwise to OFF NOTE Knob cannot be turned from PILOT to OFF unless knob is pushed in slightly Do not force 6 Wait t...

Страница 23: ...e control Refer to remote instructions for detailed operation information FOR YOUR SAFETY READ BEFORE LIGHTING WARNING If you do not follow these instructions exactly a fire or explosion may result ca...

Страница 24: ...le to cool When the thermocouple cools the heater will shut down THERMOPILE PILOT THERMOCOUPLE LPG THERMOCOUPLE NATURAL Correct Pilot Flame Pattern for MILLIVOLT Figure 41 THERMOPILE PILOT THERMOCOUPL...

Страница 25: ...anufacturing fabricating and shipping various components of this appliance are treated with certain oils films or bonding agents These chemicals are not harmful but may produce annoying smoke and smel...

Страница 26: ...urner assembly 2 When facing the appliance the remote receiver must be placed to the left of the gas valve Refer to remote control installation and operating instructions for more details on remote co...

Страница 27: ...the system s design If the signal light does not illuminate check the position of the transmitter s battery REMOTE RECEIVER Figure 47 The remote receiver operates on 4 AA size 1 5V batteries It is re...

Страница 28: ...s not included be used to make connections between the terminal wiring block on the millivolt gas valve or electronic module and the wire terminals on the remote receiver For the best results use 18 g...

Страница 29: ...s between the remote receiver and the gas valve Recommended length is no longer than 20 feet The transmitter should operate with as little as 5 0 volts battery power TROUBLE SHOOTING If you encounter...

Страница 30: ...position c Control knob not pressed in while in PILOT position Press in control knob while in PILOT position d Airingaslineswheninstalled Continueholdingdowncontrol knob Repeat igniting operation unti...

Страница 31: ...S SUPPLY TO THE APPLIANCE PRIOR TO REMOVING OR REINSERTING THE BAT TERIES IN THE RECEIVER WARNING FIRE HAZARD CAN CAUSE SEVERE INJURY OR DEATH THE RECEIVER CAUSES IGNITION OF THE APPLIANCE THE APPLIAN...

Страница 32: ...51 Figure 50 Proflame Transmitter Figure 51 Transmitter LCD display RECEIVER The Proflame Receiver Figures 52a and 52b connects directly to the gas valve and stepper motor with a wiring harness The R...

Страница 33: ...articular code of that Transmitter The system is now initialized Temperature indication Display With the system in the OFF position press the Thermostat Key and the Mode Key at the same time Look at t...

Страница 34: ...he Down Arrow Key once will reduce the flame height by one step until the flame is turned off The Up Arrow Key will increase the flame height each time it is pressed If the Up Arrow Key is pressed whi...

Страница 35: ...re is dis played on the LCD screen of the Transmitter SET TEMPERATURE ROOM TEMPERATURE Figure 60a Figure 60b Smart Thermostat Transmitter Operation The Smart Thermostat function adjusts the flame heig...

Страница 36: ...n will disappear Figure 64 Receiver The life span of the Receiver batteries depends on various factors quality of the batteries used the number of ignitions of the appli ance the number of changes to...

Страница 37: ...t igniter Once the pilot sensor heats up after a few seconds the valve will be energized allowing gas to flow to the burner 1 Follow the SAFETY and LIGHTING INSTRUCTIONS for In termittent Pilot contro...

Страница 38: ...e installed in an aftermarket permanently located manufactured mobile home where not prohibited by local codes This appliance is not convertible for use with other gases WARNING Improper installation...

Страница 39: ...erify that the power supply AC DC adapter is present and that the batteries inside the receiver and or optional battery pack are fresh and installed with correct polarity Make sure all the connections...

Страница 40: ...4 Replace the DFC board 1 Verify the electrical connections integrity and make sure they are in accordance with the relevant system wiring diagram If necessary replace the wire harness 2 If pilot flow...

Страница 41: ...oltage at ignition between the EV1 terminal and the ground connection on the valve body 5 1 If the voltage is greater than 0 then Replace Valve 5 2 Or Replace DFC 6 Check the pressure at the outlet pr...

Страница 42: ...VFLL38FP9 INDEX NO PART NO DESCRIPTION 1 30378 INNER FIREBOX TOP ASSEMBLY 2 DV612 BRACKET USED AS GLASS RE TAINER 3 30291 ACCENT LIGHT COVER PLATE 4 R11231 GLASS 5 29483 BURNER COVER ASSEMBLY 6 29465...

Страница 43: ...32707 8 0714 Page 43 VFLL38FP 3 9 EXPLODED VIEW...

Страница 44: ...NO PART NO DESCRIPTION 1 32662 INNER FIREBOX TOP ASSEMBLY 2 DV612 BRACKET USED AS GLASS RE TAINER 3 30291 ACCENT LIGHT COVER PLATE 4 R11746 GLASS 5 32820 BURNER COVER ASSEMBLY 6 32681 BURNER BOX BACK...

Страница 45: ...32707 8 0714 Page 45 VFLL48FP 3 9 EXPLODED VIEW...

Страница 46: ...te control thermostat accessory or other part fail because of defective workmanship within one year from the date of purchase Empire will repair or replace at Empire s option Duties Of The Owner The a...

Страница 47: ...anty parts All parts listed in the Parts List have a Part Number When ordering parts first obtain the Model Number and Serial Number from the name plate on your equipment Then determine the Part Numbe...

Страница 48: ...t Systems Inc 918 Freeburg Ave Belleville IL 62220 If you have a general question about our products please e mail us at info empirecomfort com If you have a service or repair question please contact...

Отзывы: