32707-8-0714
Page 24
Figures 41 and 43
show a correct pilot flame pattern. The correct
flame will be blue and will extend beyond the thermocouple. The
flame will surround the thermocouple just below the tip. A slight
yellow flame may occur where the pilot flame and main burner flame
meet.
Figures 42 and 44
show an incorrect pilot flame pattern.
The incorrect pilot flame is not touching the thermocouple. This will
cause the thermocouple to cool. When the thermocouple cools, the
heater will shut down.
THERMOPILE
PILOT
THERMOCOUPLE
(LPG)
THERMOCOUPLE
(NATURAL)
Correct Pilot Flame Pattern for MILLIVOLT
Figure 41
THERMOPILE
PILOT
THERMOCOUPLE
(LPG)
THERMOCOUPLE
(NATURAL)
Incorrect Pilot Flame Pattern for MILLIVOLT
Figure 42
If pilot flame pattern is incorrect, as shown in
Figure 42:
• See Millivolt Troubleshooting, page 30.
PILOT FLAME CHARACTERISTICS
PILOT
SENSOR
IGNITOR
Correct Pilot Flame Pattern for IP
Figure 43
PILOT
SENSOR
IGNITOR
Incorrect Pilot Flame Pattern for IP
Figure 44
If pilot flame pattern is incorrect, as shown in
Figure 44:
• See IP Troubleshooting, pages 39 - 41.