background image

Page 17

VFH-33

HI/LO
REGULATOR

CONTROL
KNOB

PIEZO
IGNITOR

FOR YOUR SAFETY READ BEFORE LIGHTING

WARNING: If you do not follow these instructions exactly, a fire or explosion may result

causing property damage, personal injury or loss of life.

A. This appliance has a pilot which must be lighted by

hand. When lighting the pilot, follow these instructions
exactly.

B. BEFORE LIGHTING smell all around the appliance

area for gas. Be sure to smell next to the floor because
some gas is heavier than air and will settle on the floor.

WHAT TO DO IF YOU SMELL GAS

• Do not try to light any appliance.
• Do not touch any electrical switch;

do not use any phone in your building.

• Immediately call your gas supplier from a neigh-

bor's phone. Follow the gas supplier's instructions.

• If you cannot reach your gas supplier, call the fire

department.

C. Use only your hand to push in or turn the gas control

knob. Never use tools. If the knob will not push in or
turn by hand, don't try to repair it; call a qualified
service technician. Force or attempted repair may
result in a fire or explosion.

D. Do not use this appliance if any part has been under

water. Immediately call a qualified service techni-
cian to inspect the appliance and to replace any part
of the control system and any gas control which has
been under water.

LIGHTING INSTRUCTIONS

TO TURN OFF GAS TO APPLIANCE

1. Turn control knob clockwise 

 to OFF position to

completely shut off the heater.

2. If applicable: Turn ON/OFF switch to OFF position and/

or set thermostat (if present) to lowest setting. If appli-
cable: Turn off all electric power to the heater.

1. STOP! Read the safety information label.
2. Make sure the manual shutoff valve is fully open.
3. This gas log set is equipped with an ignition device (piezo)

which lights the pilot. If piezo ignitor does not light the
pilot, refer to Step 7.

4. Turn gas control knob clockwise 

  to the “OFF”

position, set the thermostat to the lowest setting and turn
ON/OFF switch to OFF position.

5. Wait ten (10) minutes to clear out any gas. Then smell for

gas, including near the floor. If you smell gas STOP! Fol-
low “B” in the safety information label. If you do not smell
gas, go to the next step.

6. From OFF position, turn the gas control knob counterclock-

wise 

 to “Pilot” position. Push in and hold control

knob for 5 seconds.

7. With the control knob pushed in, repeatedly push the piezo

ignitor button until pilot is lit (or use a match to light
pilot).

8. Continue pushing the control knob in for a further 60 sec-

onds to prevent the flame detector from shutting off the
gas while the probe is warming up. Release the control
knob.

9. Turn gas control knob counterclockwise

  to the

“ON” position.

10. After the pilot has been lit for one minute, the burner can

be turned on. Turn the ON/OFF switch to “ON” position
or adjust thermostat to desired setting.

11. If the gas logs will not operate, follow the instructions

“To Turn Off Gas To Appliance” and call your service
technician or gas supplier.

Wait 30 seconds before readjusting the heater when the con-
trol knob has been turned down to a lower setting.

VFH-33R LIGHTING INSTRUCTIONS

Содержание VFH-33M-1

Страница 1: ...lified installer service agency or the gas supplier This is an unvented gas fired heater It uses air oxygen from the room in which it is installed Provisions for adequate combustion and ventila tion a...

Страница 2: ...4 Placement of Glowing Embers Rock Wool 14 Operation Instructions Flame Appearance 15 VFH 33M Lighting Instructions 16 VFH 33R Lighting Instructions 17 VFH 33T Lighting Instructions 18 Pilot Flame Cha...

Страница 3: ...ce temperature and should stay away to avoid burns or clothing ignition Young children should be carefully supervised when they are in the same room with the appliance Do not place clothing or other f...

Страница 4: ...rvice or make adjustments in an area where the conditions are such that you may not detect the odor if there has been a leak of LP Gas Odor fade due to oxidation by rust or adsorption on walls of new...

Страница 5: ...tial use of ceramic log you will detect an odor as the ceramic log is cured Also during the curing process the ceramic log will burn with a yellow flame Notice Duringinitialfiringofthisunit itspaintwi...

Страница 6: ...Unfinished EHM33 CF Mantel Cherry EHM33 OF Mantel Oak EHM33 CU Corner Mantel Unfinished EHM33 CCF Corner Mantel Cherry EHM33 COF Corner Mantel Oak EHB33 U Large Hearth Base Unfinished EHB33 CF Large...

Страница 7: ...ceilings exposed to the outside atmosphere have a continuous water vapor retarder with a rating of one perm or less with openings gasketed or sealed and b Weatherstripping has been added on openable...

Страница 8: ...12 of the ceiling and one within 12 of the floor on the wall connecting the two spaces see options 1 and 2 Figure 1 You can also remove door intoadjoiningroom seeoption3 Figure1 Eachventilationgrill o...

Страница 9: ...t inlet of control valve and pipe capped or plugged for pressure test Never pressure test with appliance connected control valve will sustain damage A gas valve and ground joint union should be instal...

Страница 10: ...wall or material should not be less than 8 inches 2 Clearances from the top of the fireplace opening to the ceiling should not be less than 36 inches Mantel Clearances for Built in Installation Figur...

Страница 11: ...arthbaseaccessories When installing the corner mantel use the EHB CU EHB CCF EHB COF hearth base accessories The hearth base is optional for these installations You can install the fireplace face mant...

Страница 12: ...antel above the fireplace you must follow the clearances shown in Figure 5 page 10 Follow the instructions below to install the fireplace in this manner Frame in rough opening Use dimensions shown in...

Страница 13: ...s lowered 3 Remove top louver from appliance by removing 4 truss head Phillips screws 4 Insert the trim top into the top interior of the appliance Position the 3 slots in the trim top downward Align t...

Страница 14: ...tion with flue damper closed State and local codes in some areas prohibit the use of vent free heaters Figure 14 PLACEMENT OF GLOWING EMBERS ROCK WOOL Provided with the log set is a small bag of glowi...

Страница 15: ...ng agents These chemicals are not harmful but may produce annoying smoke and smells as they are burned off during the initial operation of the appliance possibly causing headaches or eye or lung irrit...

Страница 16: ...control knob clockwise to the OFF position NOTE Knob cannot be turned to OFF unless knob is pushed in slightly Do not force 5 Wait ten 10 minutes to clear out any gas Then smell for gas including near...

Страница 17: ...Turn ON OFF switch to OFF position and or set thermostat if present to lowest setting If appli cable Turn off all electric power to the heater 1 STOP Read the safety information label 2 Make sure the...

Страница 18: ...force TO TURN OFF GAS TO APPLIANCE 1 Set thermostat gas control knob to lowest setting 2 Turn off all electric power to appliance if service is to be performed if applicable LIGHTING INSTRUCTIONS 7 Tu...

Страница 19: ...re 20 If pilot flame pattern is incorrect as shown in Figure 20 See Troubleshooting page 22 Cleaning and Maintenance Pilot Oxygen Depletion Sensor Pilot Figure 21 When the pilot has a large yellow tip...

Страница 20: ...PILOT is the PILOT position Position 1 The input will be 25 000 BTUH Position 2 The input will be 20 000 BTUH Position 3 The input will be 15 000 BTUH VFH 33R AND VFH 33T Main Burner Operation The gas...

Страница 21: ...components may be checked with a millivolt meter 0 1000 MV range Remote Receiver Use the following steps to place the remote receiver adjacent to the gas valve Attention The remote receiver bracket i...

Страница 22: ...assembly or get it serviced g Gas regulator setting is not correct Replace gas regulator 7 ODS pilot lights but flame goes out when control knob is released a Control knob not fully pressed in Press i...

Страница 23: ...Assembly 2 10765 TrimSide Left 3 10764 TrimSide Right 4 10603 OuterCasingAssembly 5 DVF 076 InsideMountingFlange 2Required 6 DVF 088 NailingFlange 4Required 7 EL 031 DoorStop 8 10606 InnerCasingAssemb...

Страница 24: ...LVALVECOVER FORWARD 16 R 5024 MANUALCONTROLROD 17 R 5040 CONTROLKNOB 18 R 2313 PIEZOIGNITOR Index Part No Number Description Index Part No Number Description NOTSHOWN P 254 46ORIFICE NATONLY NOTSHOWN...

Страница 25: ...he Part Number not the Index Number and the Description of each part from the following appropriate illustration and list Be sure to give all this information Fireplace Model Number Part Description F...

Страница 26: ...ped liner mounting brackets with screw holes in the inner casing Use 1 liner mounting bracket for each side brick liner and use 2 liner mounting brackets for the rear brick liner Attach the 4 Z shaped...

Страница 27: ...rd 3 If fireplace is installed in a framed enclosure disconnect flexible gas line from gas supply Remove fireplace from framed enclosure in order to route cord set Caution Do not damage flexible gas l...

Страница 28: ...electrically grounded CAUTION Label all wires prior to disconnection when servicing controls Wiring errors can cause improper and dangerous operation Verify proper operation after servicing Oiling Bl...

Страница 29: ...0 LINER MOUNTING BRACKET FRONT 2 REQUIRED 2 R 2802 BRICK LINER SIDE 2 REQUIRED 3 R 2803 BRICK LINER REAR 4 SR 178 LINER MOUNTING BRACKET REAR 4 REQUIRED FBT 2 BRASSTRIMKIT 1 DVF 118 BRASS TRIM SIDE LE...

Страница 30: ...Page 30 VFH 33 ACCESSORY PARTS VIEW FWS 1 WALL SWITCH FBT 4 EXTENDED BLACK FRAME VFHL 33BR 1 BRASS LOUVERS...

Страница 31: ...Page 31 VFH 33 Service Notes...

Страница 32: ...Page 32 VFH 33 Empire Comfort Systems Inc Nine Eighteen Freeburg Ave Belleville Illinois62222 0529 PH 1 800 851 3153 FAX 1 800 443 8648 E MAIL info empirecomfort com WEBSITE www empirecomfort com...