24325-0-0708
Page 8
Remote Control
Options &
Accessories
Description
FRBC
Millivolt Battery Remote ON/OFF
FRBTC
Millivolt Battery Remote T-Stat
FRBTP
Millivolt Battery Remote with Thermostat
TRW
Millivolt Wireless Wall Thermostat
TMV
Millivolt Reed Switch Wall Thermostat
FWS-1
Millivolt Wall Switch
FREC
Electric Remote
Venting
Options
Description
DVVK-4TSP
(DVVK-4TS)
Top Vent Kit (Horz.) - 5" to 7" wall thickness
DVVK-4TP
(DVVK-4T)
Top Vent Kit (Horz.) - 8" to 11" wall thickness
DVVK-4RP
(DVVK-4R)
Rear Vent Kit (Horz.) - 5" to 7" wall thickness
DVVK-4VP
(DVVK-4V)
Vertical Vent Kit
DVVK-4F
Horizontal Flex Vent Kit (4' Flex)
DVVK-4RE
Horizontal Round Termination wall thickness -
5" to 13 3/4"
DV822
Vinyl Siding Kit for DVVK-4RE
DVVK-4FV
Vertical Flex Vent Kit (6' Flex / 4' Rigid = 10' Total)
DVEK-10
10' Vent Extension Kit
DVEK-25
25' Vent Extension Kit
NOTE: Air shutter settings are factory minimum settings. Some
venting configurations may require minor air shutter adjustments
for optimum performance.
SPECIFICATIONS
DVP36(SP,PP) Nat Models
Input Btu/hr Maximum
35,000
Btu/hr Minimum (millivolt only)
24,000
KWH (Maximum)
10.15
(Minimum)
6.96
Orifice
#33
Air Shutter Opening
5/16"
DVP36(SP,PP) LP Models
Input Btu/hr Maximum
35,000
Btu/hr Minimum (millivolt only)
28,000
KWH (Maximum)
10.15
(Minimum)
8.12
Orifice
1.75 mm
Air Shutter Opening
FULL OPEN
DVP36(SP,PP) Nat and LP Models
Height without standoff
34 3/4" (883 mm)
Width, Face
39"
Depth
24"
Gas Inlet Shutoff Valve (pipe)
1/2" NPT