38142-2-0719
Page 9
FROM FRONT OF
APPLIANCE TO
GAS LINE HOLE
3 ½”
GAS LINE HOLE
BVD34 SERIES - 10”
BVD,P (36,42) - 13 ½”
Figure 7
BURNER ASSEMBLY
REAR TAB (BURNER BASE)
LOCATIONS
FLEXIBLE GAS CONNECTOR
GAS SUPPLY LINE
FIREBOX BOTTOM
CUTOUT ACCESS
SLIDING
VALVE ACCESS
COVER
PIEZO
IGNITER
Figure 8
GAS SUPPLY (CONT'd)
Checking manifold Pressures
Both Propane and Natural Gas valves have a built-in pressure
regulator in the gas valve. Natural Gas models will have a
manifold pressure of approximately 3.5" w.c. (.871kPa) at
the valve outlet with the inlet pressure to the valve from a
minimum of 4.5" w.c. (1.120kPa) for the purpose of input
adjustment to a maximum of 14.0" w.c. (3.484kPa). Propane
Gas models will have a manifold pressure approximately 10.0"
w.c. (2.49kPa) at the valve outlet with the inlet pressure to the
valve from a minimum of 10.8" w.c. (2.68kPa) for the purpose
of input adjustment to a maximum of 14.0" w.c. (3.484kPa).
f i r e - p a r t s . c o m