38142-2-0719
Page 7
mantel Chart (Figure 3)
12”
TOP EDGE OF FIREPLACE
12” (305mm)
10” (254mm)
MANTEL
COMBUSTIBLE TRIM AND MANTELS
ALLOWED IN SHADED AREA
1/4”
(6.35mm)
3”
4”
5”
6”
8”
10 3/4”
3/4”
1 ½”
2 1/4”
3”
3 3/4”
4 ½”
6”
8”
1”
2”
Figure 3
Clearances (Figure 4)
Clearance from top front edge of fireplace to ceiling is 36"
Clearance from side of fireplace to adjacent sidewall is 6".
Figure 4
Figure 5
NOTE:
When you install your Fireplace on
wall corner positions, a minimum of 6 inches
clearance must be maintained from the
perpendicular side wall and the screened
opening of the appliance.
Figure 2
Combustible material
No greeting cards, stockings or ornamentation of any type
should be placed on or attached to the fireplace. The flow of
heat can ignite combustibles.
CLEARANCE TO COmBUSTIBLES
Back
0" (0 mm)
Side
0" (0 mm)
Floor
0" (0 mm)
Top Stand-off
0" (0 mm)
Top Framing Edge
1" (25mm)
SEE MANTLE CHART FOR
MAXIMUM MANTLE DEPTH
NAILING
FLANGES
GLASS FRONT
(OPTIONAL)
TOP FRAMING
LEDGE
FINISHED WALL
(COMBUSTIBLE)
SEE MANTLE CHART
FOR MINIMUM HEIGHT
OF MANTLE ABOVE UNIT
2" x 4" HEADER
STAND OFF
3" (76 mm) HEIGHT
ABOVE TOP OF
FIREPLACE
CLEARANCES
LOCATING FIREPLACE