background image

Page 5

R-2688

Instructions to Installer
1.

Installer must leave instruction manual with owner after
installation.

2.

Installer must have owner fill out and mail warranty card
supplied with unvented room heater.

3.

Installer should show owner how to start and operate un-
vented room heater.

Always consult your local Building Department regarding regu-
lations, codes or ordinances which apply to the installation of an
unvented room heater.

This appliance may be installed in an aftermarket* permanently
located, manufactured (mobile) home, where not prohibited by
state or local codes.

*Aftermarket: Completion of sale, not for purpose of resale, from

the manufacturer.

This appliance is only for use with the type of gas indicated on the
rating plate. This appliance is not convertible for use with other
gases.

General Information
This EE-25-2 is design certified in accordance with American
National Standard Z21.11.2b-1998 by the American Gas Associa-
tion Laboratories as an Unvented Room Heater and should be
installed according to these instructions.

Attention: During initial use of ceramic log you will detect an
odor as the ceramic log is cured. Also, during the curing
process the ceramic log will burn with a yellow flame.

Any alteration of the original design, installed other than as
shown in these instructions or use with a type of gas not shown
on the rating plate is the responsibility of the person and
company making the change.

Important
All correspondence should refer to complete Model No., Serial
No. and type of gas.

Notice: During initial firing of this unit, its paint will bake out, and
smoke will occur. To prevent triggering of smoke alarms, ventilate
the room in which the unit is installed.

Qualified Installing Agency
Installation and replacement of gas piping, gas utilization equip-
ment or accessories and repair and servicing of equipment shall be
performed only by a qualified agency. The term "qualified agency"
means any individual, firm, corporation or company which either
in person or through a representative is engaged in and is respon-
sible for (a) the installation or replacement of gas piping or (b) the
connection, installation, repair or servicing of equipment, who is
experienced in such work, familiar with all precautions required
and has complied with all the requirements of the authority having
jurisdiction.

The installation must conform with local codes or, in the absence
of local codes, with the National Fuel Gas Code, ANSI Z223.1.*

*Available from the American National Standards Institute, Inc., 11 West 42nd St.,
New York, N.Y. 10036.

Well Head Gas Installations
Some natural gas utilities use "well head" gas. This may affect the
Btu output of the unit. Contact the gas company for the heating
value. Contact the manufacturer or your gas company before
changing spud/orifice size.

High Altitudes
For altitudes/elevations above 2,000 feet (610m), ratings should
be reduced at the rate of 4 percent for each 1,000 feet (305m)
above sea level. Contact the manufacturer or your gas company
before changing spud/orifice size.

Accessories
Blower

EEB-1

Oak Mantel with Base

EEM-O

Mahogany Mantel with Base

EEM-M

Corner Mahogany Mantel

EEM-CM

Corner Oak Mantel

EEM-CO

Floor Stand

EES-25

Model

EE-25-2

Input BTU/HR (KW/H) Max.

25,000 ( 7.3)

BTU/HR (KW/H) Min.

14,000 (4.1)

Height

25 15/32" ( 647mm)

Width

21 1/8" (537mm)

Depth

6 3/8" (162mm)

Gas Inlet

3/8" (10mm)

INTRODUCTION

SPECIFICATIONS

Содержание EE-25-2

Страница 1: ...edbyaqualifiedinstaller service agency or the gas supplier INSTALLATION INSTRUCTIONS AND OWNER S MANUAL UNVENTED ROOM HEATER MODEL EE 25 2 EFFECTIVE DATE APRIL 2001 This is an unvented gas fired heate...

Страница 2: ...and Ventilation Air 6 Gas Supply 7 Clearances 8 Combustible Material 8 Wall Mount Installation 9 Optional Floor Stand Installation 9 Lighting Instructions 10 Main Burner Flame Characteristics 11 Pilo...

Страница 3: ...THOUT FRONT PANEL INSTALLED IMPORTANT SAFETY INFORMATION WARNING When used without adequate combustion and ventilation air heater may give off CARBON MONOXIDE an odor less poisonous gas Do not install...

Страница 4: ...rvice or make adjustments in an area where the conditions are such that you may not detect the odor if there has been a leak of LP Gas Odor fade due to oxidation by rust or adsorption on walls of new...

Страница 5: ...eout and smokewilloccur Topreventtriggeringofsmokealarms ventilate the room in which the unit is installed Qualified Installing Agency Installation and replacement of gas piping gas utilization equip...

Страница 6: ...may be located and for determining if this area fits the definition of an unconfined space The maximum input of the EE 25 2 is 25 000 Btu per hour Based on the 50 cubic feet per 1 000 Btu per hour for...

Страница 7: ...rip line be installed near the gas inlet This should consist of a vertical length of pipe tee connected into the gas line that is capped on the bottom in which condensation and foreign particles may c...

Страница 8: ...ing tile etc 2 inches 51mm Provide adequate clearances around air openings Adequate accessibility clearances for purposes of servicing and proper operation must be provided Figure 3 Figure 4 COMBUSTIB...

Страница 9: ...rs Refer to Figure 8 4 Mount heater onto the 3 screwheads and complete tighteningthescrewheadstotheplasticexpansionanchors 5 Connect the gas line Figure 8 OPTIONAL FLOOR STAND INSTALLATION Figure 7 Op...

Страница 10: ...click when the safety magnet in the gas control is de energized Pilot can now be relighted Repeat steps 5 through 9 11 Turn gas control knob counterclockwise to HI 12 Replace front panel 13 Turn on a...

Страница 11: ...roper flame The main burner may be cleaned by forcing water into the ports and the throat of the burner The burner should be blown dry or heated to remove all water before replacing To remove main bur...

Страница 12: ...Check for gas leaks To Remove Main Burner Orifice 1 Grasp the orifice fitting with a 5 8 16mm open end wrench 2 Use 3 8 10mm open end wrench to remove main burner orifice from orifice fitting turn cou...

Страница 13: ...VF 140 Top Shield 10 VF 131 Chamber Back 11 P 213 Orifice NAT Gas 11 P 204 Orifice LP Gas 12 P 212 Orifice Fitting 13 VF 138 Front Shield Assembly 14 SR 209 Regulator Bracket 15 R 2784 Inlet Regulato...

Страница 14: ...Page 14 R 2688 PARTS VIEW...

Страница 15: ...de of front shield assembly by measuring down 9 229mm from the upper right corner of the shield assembly See Figure 1 Align 3 16 5mm spacer and oblong clearance hole on switch box with 1 8 3mm screw h...

Страница 16: ...to the adapter and be electrically grounded CAUTION Label all wires prior to disconnection when servicing controls Wiring errors can cause improper and dangerous operation Verify proper operation afte...

Отзывы: