background image

Page 1

R-2688

WARNING: If the information in this
manual is not followed exactly, a fire
or explosion may result causing prop-
erty damage, personal injury or loss
of life.

 — Do not store or use gasoline or other

flammable vapors and liquids in the
vicinity of this or any other appliance.

 — WHAT TO DO IF YOU SMELL GAS

Do not try to light any appliance.

Do not touch any electrical switch;
do not use any phone in your build-
ing.

Immediately call your gas supplier
from a neighbor's phone. Follow
the gas supplier's instructions.

If you cannot reach your gas sup-
plier, call the fire department.

 — Installation and service must be per-

formed by a qualified installer, service
agency or the gas supplier.

INSTALLATION INSTRUCTIONS

AND

OWNER'S MANUAL

UNVENTED

ROOM HEATER

MODEL

EE-25-2

EFFECTIVE DATE

APRIL, 2001

This is an unvented gas-fired heater. It
uses air (oxygen) from the room in which
it is installed. Provisions for adequate com-
bustion and ventilation air must be pro-
vided. Refer to page 6.

WARNING: If not installed, operated and
maintained in accordance with the manu-
facturer's instructions, this product could
expose you to substances in fuel or from
fuel combustion which can cause death or
serious illness.

WATER VAPOR: A BY-PRODUCT OF
UNVENTED ROOM HEATERS
Water vapor is a by-product of gas
combustion. An unvented room heater
produces approximately one (1) ounce
(30ml) of water for every 1,000 BTU's
(.3KW's) of gas input per hour. Refer to
page 6.

Содержание EE-25-2

Страница 1: ...edbyaqualifiedinstaller service agency or the gas supplier INSTALLATION INSTRUCTIONS AND OWNER S MANUAL UNVENTED ROOM HEATER MODEL EE 25 2 EFFECTIVE DATE APRIL 2001 This is an unvented gas fired heate...

Страница 2: ...and Ventilation Air 6 Gas Supply 7 Clearances 8 Combustible Material 8 Wall Mount Installation 9 Optional Floor Stand Installation 9 Lighting Instructions 10 Main Burner Flame Characteristics 11 Pilo...

Страница 3: ...THOUT FRONT PANEL INSTALLED IMPORTANT SAFETY INFORMATION WARNING When used without adequate combustion and ventilation air heater may give off CARBON MONOXIDE an odor less poisonous gas Do not install...

Страница 4: ...rvice or make adjustments in an area where the conditions are such that you may not detect the odor if there has been a leak of LP Gas Odor fade due to oxidation by rust or adsorption on walls of new...

Страница 5: ...eout and smokewilloccur Topreventtriggeringofsmokealarms ventilate the room in which the unit is installed Qualified Installing Agency Installation and replacement of gas piping gas utilization equip...

Страница 6: ...may be located and for determining if this area fits the definition of an unconfined space The maximum input of the EE 25 2 is 25 000 Btu per hour Based on the 50 cubic feet per 1 000 Btu per hour for...

Страница 7: ...rip line be installed near the gas inlet This should consist of a vertical length of pipe tee connected into the gas line that is capped on the bottom in which condensation and foreign particles may c...

Страница 8: ...ing tile etc 2 inches 51mm Provide adequate clearances around air openings Adequate accessibility clearances for purposes of servicing and proper operation must be provided Figure 3 Figure 4 COMBUSTIB...

Страница 9: ...rs Refer to Figure 8 4 Mount heater onto the 3 screwheads and complete tighteningthescrewheadstotheplasticexpansionanchors 5 Connect the gas line Figure 8 OPTIONAL FLOOR STAND INSTALLATION Figure 7 Op...

Страница 10: ...click when the safety magnet in the gas control is de energized Pilot can now be relighted Repeat steps 5 through 9 11 Turn gas control knob counterclockwise to HI 12 Replace front panel 13 Turn on a...

Страница 11: ...roper flame The main burner may be cleaned by forcing water into the ports and the throat of the burner The burner should be blown dry or heated to remove all water before replacing To remove main bur...

Страница 12: ...Check for gas leaks To Remove Main Burner Orifice 1 Grasp the orifice fitting with a 5 8 16mm open end wrench 2 Use 3 8 10mm open end wrench to remove main burner orifice from orifice fitting turn cou...

Страница 13: ...VF 140 Top Shield 10 VF 131 Chamber Back 11 P 213 Orifice NAT Gas 11 P 204 Orifice LP Gas 12 P 212 Orifice Fitting 13 VF 138 Front Shield Assembly 14 SR 209 Regulator Bracket 15 R 2784 Inlet Regulato...

Страница 14: ...Page 14 R 2688 PARTS VIEW...

Страница 15: ...de of front shield assembly by measuring down 9 229mm from the upper right corner of the shield assembly See Figure 1 Align 3 16 5mm spacer and oblong clearance hole on switch box with 1 8 3mm screw h...

Страница 16: ...to the adapter and be electrically grounded CAUTION Label all wires prior to disconnection when servicing controls Wiring errors can cause improper and dangerous operation Verify proper operation afte...