MAINTENANCE AND SERVICE
Reassembly and Resealing Gas Accumulation Relief System
Glass Frame Assembly and Combustion Chamber
Whenever the glass frame assembly is pivoted open by a delayed
ignition in the main burner, the glass frame assembly gaskets and
combustion chamber must be examined by a qualified service person
for damage. All damaged gaskets on the glass frame assembly and
combustion chamber must be replaced by a qualified service person.
If damage occurs to the combustion chamber, it must be replaced
by a qualified service person. Contact Empire Comfort Systems,
Inc. for replacement parts.
Glass Removal and Replacement
1. Remove decorative front doors (where applicable) by opening
and lifting straight up.
2. Remove decorative front by tilting lower portion forward to
release ball catch and lifting front off mounting bracket. See
Figure 69.
3. Release two glass frame clamps at bottom of firebox.
4. Remove glass frame.
5. Place glass frame onto firebox.
6. Attach two glass frame clamps at bottom of firebox.
7. Replace decorative front by hooking front mounting brackets.
Be sure to lower front with slight angle to keep ball clasp from
scratching the front of appliance. Push in lower portion to lock
ball clasp.
8. Replace decorative front doors by aligning hinges over posts.
Figure 68
Figure 69
Содержание DVP42DP31N-2
Страница 21: ...31457 1 0513 Page 21 Figure 32 Figure 33 Figure 34 EXAMPLES TOP VENT RUN...
Страница 37: ...31457 1 0513 Page 37 Figure 63 MILLIVOLT STANDING PILOT WIRING DIAGRAM...
Страница 58: ...31457 1 0513 Page 58 PARTS VIEW...
Страница 67: ...31457 1 0513 Page 67 APPLIANCE SERVICE HISTORY Date Dealer Name Service Technician Name Service Performed Notes...