The conversion shall be carried out in accordance with the
requirements of the provincial authorities having jurisdiction
and in accordance with the requirements of the CSA B149.2
installation code (Canada) and with the requirements of the
National Fuel Gas Code Z223.1/NFPA 54 (United States).
WARNING
This conversion kit shall be installed by a qualified
service agency in accordance with the manufacturer's
instructions and all applicable codes and requirements
of the authority having jurisdiction. If the information in
this instruction is not followed exactly, a fire, explosion,
or production of carbon monoxide may result causing
property damage, personal injury, or loss of life. The
qualified service agency is responsible for the proper
installation of this kit. The installation is not proper and
complete until the operation of the converted appliance is
checked as specified in the manufacturer's instructions
supplied with the kit.
Installer notice
:
Using an ink pen, fill out the required information
on the conversion label. Remove the backing from label and stick
label in a visible position on bottom of fireplace close to gas valve.
Installer notice
:
These instructions must be left with the appliance.
Instructions for converting your direct ignition fireplace from
natural gas to propane/LP gas.
All direct ignition fireplaces are shipped from the factory equipped
to operate on natural gas. To convert the direct ignition fireplace to
operate on propane/LP gas, follow the instructions on this page.
Please see the appropriate parts list for your model for parts included
with the direct ignition fireplace.
Check the items in the kit with the parts list. Notify the supplier of
any items that are missing before installing the conversion kit.
1. Turn off the gas supply.
2. Turn off the electrical supply to the appliance if so equipped.
3. Remove top louver and lower bottom louver.
4. Remove glass frame assembly.
5. Remove logs from burner assembly.
VALVE CONVERSION
6. Remove plastic cap from regulator fitting. Unscrew fitting using
a 11/16" wrench. Turn fitting over so end of fitting marked "LPG"
(red) screws into valve. Tighten fitting (snug only). Replace
plastic cap.
7. Remove 1/4" screw from air shutter.
8. Located to the right of electrodes is a burner hold-down tab.
Using needle-nose pliers, bend burner hold-down tab off the
main burner.
9. Remove main burner by pivoting main burner forward as you
slide main burner from left to right. Be careful as you remove
main burner in order to protect the electrodes from being
damaged.
DIRECT IGNITION PROPANE/LP GAS CONVERSION
10. Remove air shutter from orifice fitting.
11. Remove natural gas main burner orifice from orifice fitting.
12. Install propane/LP main burner orifice marked #52.
Important: Failure to install the correct orifice will result in
unit over-firing that could overheat the appliance and result
in a fire.
13. Replace air shutter onto orifice fitting. Air shutter must be
threaded and bottomed-out onto orifice fitting.
14. Replace main burner onto burner assembly. Place main
burner beneath electrodes, slide main burner from right to
left into burner location, and pivot main burner away from
you and into air shutter.
15. Set air shutter opening at FULL OPEN. Tighten air shutter in
place with 1/4" screw from step 7.
16. Using needle-nose pliers, bend burner hold-down tab over
main burner.
17. Refer to log placement, page 34 to place logs onto burner
assembly.
18. Loosen screw and attach a manometer or pressure gauge to
the outlet pressure tap of the control valve.
19. Turn on the gas supply. Turn on the electrical supply to the
appliance. Check for gas leaks using soap and water solution
or leak detection solution. Bubbles indicate a leak that MUST
be corrected. Do not use an open flame to test for gas leaks.
20. Check the air shutter opening. See chart and illustration below.
21. Relight the main burners and verify proper burner ignition and
operation.
22. With the main burner burning, read the pressure on the
manometer or pressure gauge. The pressure on the gauge
should read between 9.8" and 10.2" w.c.
23. Turn off the gas supply. Turn off the electrical supply to the
appliance.
24. Remove the manometer or pressure gauge. Tighten the screw
in the pressure tap.
25. Turn on the gas supply. Turn on the electrical supply to the
appliance.
26. Immediately test all gas line connections and the control
valve for gas leaks using a soap and water solution or other
gas detection solution. Bubbles indicate a leak that MUST be
corrected. Do not use an open flame to test for gas leaks.
27. Using a ball point pen, fill out the conversion label that is
supplied with the conversion kit. Place the conversion label
adjacent to the rating plate.
28. Replace glass frame assembly.
29. Reinstall top and bottom louvers.
30. Test operation of fireplace once again. Allow the fireplace to
operate for at least 10 minutes and check flame coloration.
Flames on rear of burner should be yellow without any
orange-colored tip. Minor adjustment of the air shutter may
be necessary to "tune in" the proper flame color.
Содержание DVP42DP31N-2
Страница 21: ...31457 1 0513 Page 21 Figure 32 Figure 33 Figure 34 EXAMPLES TOP VENT RUN...
Страница 37: ...31457 1 0513 Page 37 Figure 63 MILLIVOLT STANDING PILOT WIRING DIAGRAM...
Страница 58: ...31457 1 0513 Page 58 PARTS VIEW...
Страница 67: ...31457 1 0513 Page 67 APPLIANCE SERVICE HISTORY Date Dealer Name Service Technician Name Service Performed Notes...