59
If any of the original wire as supplied with this unit must be replaced, it
must be replaced with equivalent gauge and temperature rated wire.
This appliance is only for use with the type of gas indicated on the rating
plate and may be installed in an aftermarket, permanently located,
manufactured (mobile) home where not prohibited by local codes. This
appliance is not convertible for use with other gases, unless a certified kit
is used.
CAUTION
Do not operate the appliance with liner panel(s) removed, or
damaged. Replacement of the liner panel(s) should be done by a
licensed or qualified service person.
WARNING
Improper installation, adjustment, alteration, service or
maintenance can cause property damage, personal injury or loss
of life. Installation and service must be performed by a qualified
installer, service agency or the gas supplier.
IPI ELECTRONIC SYSTEM WIRING DIAGRAM
CAUTION
Label all wires prior to disconnection when servicing controls.
Wiring errors can cause improper and dangerous operation.
FUSE
5X20
FUSE
MAINS
SUPPLY
CONNECTION
LIVE (120VAC)
NEUTRAL
GROUND
ROOM AIR DUCT FAN
COMBUSTION FAN
RUN INTERUPT (GREEN)
GREEN
PURPLE
GREEN
YELLOW
DVLXG SERIES
SMALL TERMINAL (SPARK)
GREEN/YELLOW
GREEN/YELLOW
WHITE
BLACK
BLACK
BLACK
BLACK
RED
LARGE TERMINAL
GREEN
RED
GREEN/YELLOW
NORMALLY CLOSED
NORMALLY OPEN
REMOTE “LEARN” (BLACK)
24VDC 40W POWER SUPPLY
LED DRIVER
+
─
FIREBOX LED
FRONT GLASS LED
BACK GLASS LED.......(DVLXGxxS ONLY)
4A 250V FUSE
(BAYONET
HOUSING)
PILOT
PRESSURE
SWITCH
BLACK
WHITE
RED (COMBUS
TION F
AN)
RED (DUC
AIR F
AN)
NON-ST
ANDARD
SIT PROFLAME 2
0.584.30
9
DO NOT REPLACE SIT
CONTROLLER WITH ANY OTHER
PROFLAME 2 VARIANT