
47
LIGHTING INSTRUCTIONS
A. This appliance must be lighted with the remote control.
When lighting the pilot, follow these instructions exactly.
B. BEFORE LIGHTING, smell around the appliance area for
gas. Be sure to smell next to the floor because some gas is
heavier than air and will settle on the floor.
What to do if you smell gas:
Do not try to light any appliance.
Do not touch any electrical switch.
Do not use any phone in your building.
Immediately call your gas supplier from a neighbors phone.
Follow the gas supplier’s instructions.
If you can not reach your gas supplier, call the fire department.
C. Use only the remote control to operate the valve. Never
use tools. If the valve does not operate, don’t try to repair it;
call a qualified service technician. Force or attempted repair
may result in fire or explosion.
D. Do not use this appliance if any part has been underwater.
Immediately call a qualified service technician to inspect the
appliance and to replace any part of the control system and
any gas control which has been underwater.
LIGHTING INSTRUCTIONS
1. STOP! Read the safety information above.
2. Turn OFF electric power to the appliance.
3. Turn the gas shut-off valve counterclockwise to the “ON”
position.
4. Wait ten minutes. Then smell for gas, including near the floor.
If you smell gas, STOP! Follow “B” in the safety information
above on this page. If you do not smell gas, go to the next step.
5. Turn ON electric power to the appliance.
6. Use the remote to turn your fireplace on. If the pilot does
not light within 60 seconds, stop and go back to step 5.
7. Refer to remote control instructions for detailed information,
control features, and operation. NOTE: Refer to
Multifunction Remote operating instructions for operating
instructions pertaining to intermittent pilot mode. If the
pilot or burner does not stay lit, stop and immediately call a
qualified service technician or gas supplier.
8. If the burner or pilot does not operate properly after
several tries, turn the gas shut-off valve clockwise to the
“OFF” position and call your service technician or gas
supplier.
9. Operation of the fireplace is controlled by a manual on/
off switch or a hand held remote control. Refer to remote
instructions for detailed operation information.
TO TURN OFF GAS TO FIREPLACE
1. Turn off all electrical power to the appliance if service is to be
performed (if applicable).
2. Locate the on/off gas shut-off and turn clockwise to Off. Do
not force the valve.
Flame Sensor
Pilot
Electrode
OFF
ON
SHUT-OFF VALVE
WARNING
If you do not follow these instructions exactly, a fire or explosion may result, causing property damage,
personal injury, or loss of life.
FOR YOUR SAFETY READ BEFORE LIGHTING