22
CAUTION
All wiring should be done by a qualified electrician and shall be
in compliance with all local, city and state building codes. Before
making the electrical connection, make sure that the main
power supply is disconnected. The fireplace, when installed,
must be electrically grounded in accordance with local codes, or
in the absence of local codes, with the National Electrical Code
ANSI/NFPA 70 (Latest Edition).
When creating the cavity for the fireplace, consideration must be
given to the location of an appropriate power supply. A grounded
110/120 volt mains power connection must be available within 2.5
feet (1 meter) of the bottom right of the fireplace.
120VAC
MAINS
SUPPLY
(IN)
VENT
FAN
(OUT)
DUCT
FAN
(OUT)
A mains isolation switch which is accessible from outside the
cavity can also be used to disconnect the power.
Regardless of the method used, it MUST ALWAYS be possible
to safely isolate the electrical supply to the appliance after it has
been fully installed.
This appliance must not be located immediately below a socket
outlet. No additional power supply is required for the power flue.
ELECTRICAL CONNECTIONS
JUNCTION BOX CONNECTIONS
Remove screws from the
three empty positions on
the right hand side of each
connector. Don't lose the
screws!
(6/32" by 1/4" screws)
BLACK (Live/Hot)
WHITE (Neutral)
GREEN (Ground/Earth)
BLACK
WHITE
GREEN
L
N
G
Supply and Vent Fan
Straight color for color matching.
Securely crimp supplied
ring terminals to all wires if
required. Check crimp by
giving each a good tug.
Screw the correct wires in
sequence as described
below.
Duct Fan Only...
BLACK (Live/Hot)
WHITE (Neutral)
GREEN (Ground/Earth)
RED
WHITE
GREEN
L
N
G
WARNING: Live wire for duct fan is red!