Brief Description of the Components
The controls are designed to be used with either Propane or
Natural Gas and can be converted by use of an OEM supplied
conversion kit.
The Intermittent Fireplace Control (IFC) is an automatic gas
ignition system based on a single micro-controller core. This
control manages all functions related to ignition, flame sensing
and supervision for atmospheric applications.
The IFC in this fireplace is set to be an intermittent ignition
control and flame monitoring with safety shutdown in case of
failure.
The IFC is set up as a stand alone AC-powered system, with no
battery backup.
See Wiring Diagram on page 58 and Lighting
Instructions on page 45.
Troubleshooting
Before proceeding with the troubleshooting table, verify that the
120VAC power supply is present.
Make sure all the connections between the wire harnesses and
system components are proper and positive.
Verify that the static inlet pressure meets the manufacturer’s
recommended inlet pressure. If necessary adjust the line pressure
regulator.
If the recommended actions for the following troubleshooting
chart do not help to address the problem consider replacing wiring
harnesses.
WARNING
Any actions performed on the gas valve, IFC, or other system
components must be performed in accordance with this
instruction manual and individual component instructions.
Replace components in accordance with this instruction manual.
INTERMITTENT CONTROL SYSTEM TROUBLESHOOTING