![Empire Comfort Systems DVCT36CBP Скачать руководство пользователя страница 19](http://html.mh-extra.com/html/empire-comfort-systems/dvct36cbp/dvct36cbp_installation-instructions-manual_2404069019.webp)
38745-4-0319
Page 19
INSTALLATION (CONT’D)
NAILING FLANGES
FLUSH WALL INSTALLATION
NONCOMBUSTIBLE
BOARD INSTALLED
OVER APPLIANCE
FINISHED
WALL
NAILING
FLANGES
SECURED
IN PLACE
FOR 1/2” DRYWALL
FOR 5/8” DRYWALL
FINISHED
WALL
NONCOMBUSTIBLE
BOARD INSTALLED
OVER APPLIANCE
FRAMING
HEADER
11”
Figure 31
Figure 32
Figure 33
Figure 34
WARNING
When finishing the fireplace never obstruct or modify the
gap around the glass frame in any manner. Provide adequate
clearances around air openings into the combustion chamber.
CAUTION
If the joints between the finished wall and the fireplace surround
(top and sides) are sealed, a 300°F minimum sealant material
must be used. These joints are not required to be sealed. Only
non-combustible material (using 300°F minimum adhesive if
needed) can be applied as facing to the fireplace surround.