38102-4-0319
Page 6
speciFications
Dvct30cBn95(n,p)-1
Dvct35cBn95(n,p)-1
propane
natural
propane
natural
Input BTU/Hr Maximum (Both Burners High)
28,500
30,000
35,000
39,000
Input BTU/Hr Minimum (Both Burners Low)
22,000
19,500
28,500
25,500
Input BTU/Hr Minimum (Only Front Burner Low)
10,000
8,500
11,000
10,000
KWH (Maximum)
8.34
8.78
10.2
11.4
KWH (Minimum) (Front Burner Only)
2.93
2.49
3.2
2.9
Orifice (Rear)
1.20mm
#47
1.40mm
2.40mm
Orifice (Front)
#59
#52
#57
#50
Air Shutter Opening (Rear)
Fully Open
Fully Closed
Fully Open
Fully Closed
Air Shutter Opening (Front)
Fully Open
Fully Closed
Fully Open
Fully Closed
Gas Inlet Shutoff Valve (Pipe)
3/8 MIF
3/8 MIF
3/8 MIF
3/8 MIF
NOTICE
:
Air shutter settings are factory minimum settings. Some venting configurations may require minor air shutter adjustments for
optimum performance.
Gas sUpplY pressUres
Gas type
Maximum
Minimum
Manifold
Natural
14
4.5
3.5
Propane
14
10.8
10