38102-4-0319
Page 21
INSTALLATION (CONT’D)
rear BUrner air sHUtter GUiDelines
vent
lenGtH
Dvct30
propane
natural
10 ft
Open
Full Closed
20 ft
1/2 - 3/4 Closed
Full Closed
30 ft
1/2 - 3/4 Closed
Full Closed
40 ft
1/2 Closed
Full Closed
vent
lenGtH
Dvct35
propane
natural
10 ft
1/2 Closed
1/2 Closed
20 ft
1/2 Closed
1/2 Closed
30 ft
3/4 Closed
3/4 Closed
40 ft
3/4 Closed
3/4 Closed
NOTICE:
The front air shutter is closed for Natural Gas and open
for Propane. No adjustment may be necessary.
23. Refer to instructions included with the surround kit to install it.
WarninG
Only surrounds and decorative fronts supplied by the
manufacturer may be used to cover integral grills on the
solid-fuel burning fireplace. No other components such as
sheet metal plates may be used to seal off vents.
POWER CORD
KNOCKOUT
10-24X3/4 TRUSS
HD SCREWS (4)
Figure 22
24. Seasonal switch must be in "ON" position.
SEASONAL
ON/OFF
SWITCH LOCA
TION
Figure 23
25. Reinstall the barrier screen.
see Figure 24.
DOOR
BARRIER
SCREEN
Figure 24
26. Install optional decorative front.