9. Install blower through firebox cutout.
See Figure 12.
Figure 12
10. Install the blower onto the prebent brackets on the blower
plate. Ensure the Velcro connects to secure the blower in
place.
See Figure 13.
Figure 13
11. Reinstall the latch assembly removed in step 8.
See Figure
11.
12. Reinstall the burner assembly and seven screws removed in
step 7.
See Figure 10.
13. Reinstall the burner and four screws removed in step 6.
See
Figure 9.
14. Reinstall the log support and secure it with the metal plate and
two screws removed in step 5.
See Figure 8.
15. Reinstall the grate three screws removed in step 4.
See Fig-
ure 7.
16. Install thermo disc by snapping into valve bracket burner as-
sembly.
See Figure 14.
FBB10 BLOWER KIT INSTALLATION (OPTIONAL)
Figure 14
17. Connect Power source into outlet.
18. Reinstall the glass frame removed in step 3.
See Figure 6.
19. Reconnect the latches at the bottom of the firebox assembly.
See Figure 5.
20. Replace bottom assembly removed in step 1.
See Figure 4.
6
2
3
4
1
5
7
BLOWER ASSEMBLY PARTS LIST
INDEX
NO.
PART
NO
DESCRIPTION
QTY
1
R2804
BLOWER ASSEMBLY
1
2
R7649
FAN, CONTROL L120-20
1
3
R3529
CORD SET, 30 INCHES
1
4
R4192
RHEOSTAT, KNOB
1
5
R4186
RHEOSTAT, 3.0 AMP 115 VAC
1
6
10088
RHEOSTAT BOX BRACKET
1
7
R11768
WIRE HARNESS, FAN CONTROL
1
Содержание DVCC32LP
Страница 39: ...32261 5 0414 Page 39 Figure 77 MILLIVOLT STANDING PILOT WIRING DIAGRAM BP3 SERIES ...
Страница 46: ...32261 5 0414 Page 46 INTERMITTENT PILOT CONTROL SYSTEM TROUBLESHOOTING BP7 SERIES ...
Страница 47: ...32261 5 0414 Page 47 INTERMITTENT PILOT CONTROL SYSTEM TROUBLESHOOTING BP7 SERIES ...
Страница 51: ...32261 5 0414 Page 51 MILLIVOLT PARTS VIEW DVCP 32 36 42 BP3 ...
Страница 53: ...32261 5 0414 Page 53 IP PARTS VIEW DVCP 32 36 42 BP7 ...