background image

R-3122

 Page 15

PLEASE NOTE:  When ordering parts, it is very important that  part number and description of part coincide.

INDEX

PART

  NO.

NUMBER

DESCRIPTION

INDEX

PART

  NO.

NUMBER

DESCRIPTION

  USE ONLY MANUFACTURER'S REPLACEMENT PARTS.  USE OF ANY OTHER PARTS COULD CAUSE INJURY OR DEATH.

1

DV-1213

TOP PLATE

2

R-3165

DOOR CLIP (2 REQUIRED)

3

DV-1204

CASING SIDE - RIGHT

4

DV-1202

CASING BACK

5

DV-1205

CASING SIDE - LEFT

6

DV-1249

AIR DROP

7

DV-1230

TURBULATOR (3 REQUIRED)

8

DV-1233

OUTLET BOX REAR

9

DV-1224

OUTLET BOX COVER

10

R-3161

FAN BLADE

11

R-3166

FAN MOTOR

12

DV-1246

MOTOR MOUNTING BRACKET

13

8720130

BUSHING (4 REQUIRED)

14

8520141

RUBBER GROMMET
(4 REQUIRED)

15

8520142

BRASS BUSHING
(4 REQUIRED)

16

R-3164

DOOR CLIP (2 REQUIRED)

17

DV-1251

INNER SHIELD - RIGHT
(INCLUDES NO. 22)

18

R-3174

FAN CONTROL SWITCH

19

R-3175

LIMIT SWITCH

20

DV-1255

INNER SHIELD FRONT

21

DV-1253

INNER SHIELD COVER PLATE
(2 REQUIRED)

22

DV-1252

INNER SHIELD -LEFT
(INCLUDES NO. 22)

23

DV-1257

EXCHANGER ASSEMBLY

24

R-3162

FILTER

25

R-3163

FILTER RETAINER

26

R-3232

PILOT - NAT (IP ONLY)

26

R-3233

PILOT - LPG (IP ONLY)

27

742126

ORIFICE - NAT (3 REQUIRED)

27

P-88-61C

ORIFICE - LPG (3 REQUIRED)

28

DV-1236

MANIFOLD

29

DV-1259

FRONT PANEL

30

722040

MANIFOLD UNION

31

852051

BUSHING 3/8 X 1/2

32

R-3170

GAS VALVE - NAT (IP ONLY)

32

R-3171

GAS VALVE - LPG (IP ONLY)

32

R-2148

GAS VALVE - NAT (SPP ONLY)

32

R-5655

GAS VALVE - LPG (SPP ONLY)

33

R-2708

PIEZO IGNITOR (SPP ONLY)

34

DV-781

OBSERVATION HOLE COVER
WITH MICA

35

712098

GASKET - OBS HOLE

36

FF-160

PIEZO BRACKET (SPP ONLY)

37

DV-1240

BURNER COMPARTMENT FRONT

38

DV-1265

BURNER COMPARTMENT BODY

39

712059

GASKET - TUBE SEAL

40

DV-775

SEAL BRACKET (SPP ONLY)

40

DV-691

SEAL BRACKET (IP ONLY)

41

712045

MANIFOLD GASKET

42

DV-1235

PILOT BRACKET (IP ONLY)

43

R-3031

BURNER (3 REQUIRED)

44

DV-1239

BURNER BRACKET

45

UH-810

TRANSFORMER MOUNTING
BRACKET (SPP ONLY)

45

UH-452

TRANSFORMER MOUNTING
BRACKET (IP ONLY)

46

R-1995

TRANSFORMER (SPP ONLY)

46

8720100

TRANSFORMER (IP ONLY)

47

UH-451

JUNCTION BOX COVER

48

DV-572

JUNCTION BOX

49

872056

BUSHING

50

872053

CORD SET

51

8720148

BUSHING

52

DV-1215

BOTTOM PLATE

53

R-3034

PILOT - NAT (SPP ONLY)

53

R-3035

PILOT - LPG (SPP ONLY)

54

GWT-021

PILOT BRACKET (SPP ONLY)

55

R-3180

ELECTRODE AND WIRE (SPP ONLY)

56

R-2256

THERMOCOUPLE -18" (SPP ONLY)

57

662024

WALL THERMOSTAT - 24 VOLT

58

DV-1273

VENT KIT COMPLETE

59

DV-1355

FLUE OUTLET TUBE

60

DV-1354

AIR INLET TUBE

61

DV-131

OUTSIDE MOUNTING PLATE

62

DV-769

VENT CAP

NOT SHOWN

DV-1261

PILOT TUBING

NOT SHOWN

742158

PILOT ORIFICE - NAT (SPP ONLY)

NOT SHOWN

742266

PILOT ORIFICE - LPG (SPP ONLY)

NOT SHOWN

742154

PILOT ORIFICE - NAT (IP ONLY)

NOT SHOWN

R-3265

PILOT ORIFICE - LPG (IP ONLY)

NOT SHOWN

R-3172

WIRE HARNESS (SPP ONLY)

NOT SHOWN

R-3173

WIRE HARNESS (IP ONLY)

NOT SHOWN

R-3236

WIRE (IP ONLY)

How To Order Repair Parts

...

Parts can be ordered only through your service person or dealer.  For best results, the service person or dealer should order parts through
the  distributor.  Parts can be shipped directly to the service person/dealer.

All parts listed in the Parts List have a Part Number.  When ordering parts, first obtain the Model Number from the name plate on your
equipment.  Then determine the Part Number (not the Index Number) and the Description of each part from the following appropriate
illustration and list.  Be sure to give all this information . . .

Furnace Model Number

Part Description

Furnace Serial Number

Kind of Gas (Propane or Natural)

Part Number

Do not order bolts, screws, washers or nuts.  They are standard hardware items and can be purchased at any local hardware store.

Shipments contingent upon strikes, fires and all causes beyond our control.

  Empire Comfort Systems, Inc.   Nine Eighteen Freeburg Ave.     Belleville, Illinois  62222-0529

Содержание DVC-35IP

Страница 1: ...l your gas supplier from a neighbor s phone Follow the gas supplier s instructions Ifyoucannotreachyourgassupplier call the fire department Installation and service must be per formed by a qualified installer service agency or the gas supplier WARNING If not installed operated and maintained in accordance with the manu facturer s instructions this product could expose you to substances in fuel or ...

Страница 2: ...Instructions to Installer 1 Installer must leave instruction manual with owner after installation 2 Installer must have owner fill out and mail warranty card supplied with furnace 3 Installer should show owner how to start and operate furnace and thermostat Warning Any change to this furnace or its control can be dan gerous This is a heating appliance and any panel door or guard removed for servic...

Страница 3: ...lights perform service or make adjustments in an area where the conditions are such that you may not detect the odor if there has been a leak of LP Gas Odor fade due to oxidation by rust or adsorption on walls of new cylinders and tanks is possible Therefore people should be particularly alert and careful when new tanks or cylinders are placed in service Odor fade can occur in new tanks or reinsta...

Страница 4: ... feet 1 83m from any pressure regulator In case of regulator malfunction the six 6 feet 1 83m distance will reduce the chance of gas entering the vent cap Locating Wall Opening The furnace is to be located on an outside wall Locate wall studs so that wall opening will be located between wall studs The furnace is 14 1 8 358mm in width and can be recessed between standard 16 406mm on center wall stu...

Страница 5: ...ual Attaching Furnace to Wall Refer to Figure 2 for the location of the 7 1 2 191mm diameter wall opening for the furnace After the wall opening has been located and cut position flue outlet on furnace in center of wall opening When attaching furnace to the wall remove that portion of baseboard and molding on the wall which is behind the furnace Attachfurnacetowall attheoutercasingtop with 2 toggl...

Страница 6: ...ceed a total depth of 10 254mm for DVC 35 See Figure 6a Warning When vinyl siding vent kit DV 822 or 2 x 4 51mm x 102mm framing is added to an existing installa tion furnace is installed do not attempt to add sections of pipe to the flue outlet tube or air inlet tube An air tight seal is required for both tubes Refer to Parts List page 15 to order tubes Figure 6 Figure 6a Mark the 6 152mm diameter...

Страница 7: ...sing its individual manual shutoff valve during any pressure testing of the gas supply piping system at test pressures equal to or less than 1 2 psig 3 5 kPa Attention If one of the above procedures results in pressures in excess of 1 2 psig 14 w c 3 5 kPa on the appliance gas valve it will result in a hazardous condition Figure 8 Checking Manifold Pressure Both Propane and Natural gas valves have...

Страница 8: ...e of the combustion exchanger assembly and flue baffles in order to clear all passageways Oiling the Motor The fan motor should be cleaned and oiled once each heating season Oil holes are located on the top at each end of the motor Use a few drops of 10 motor oil To clean the motor blow air through its ventilation openings with a vacuum cleaner or low pressure air source Wiring The appliance when ...

Страница 9: ...R 3122 Page 9 Figure 11 BURNER BOX GAS VALVE JUNCTION BOX TRANSFORMER LIMIT SWITCH FAN SWITCH FAN PIEZO IGNITOR Figure 12 ...

Страница 10: ... rating label TheServiceDepartmentatEmpireComfortSystems Inc maybe contacted to assist in servicing furnace Standing Pilot Model Servicing the Pilot and Main Burners Pilot Orifice Thermo couple and Main Burner Orifices Disconnect the gas supply at the inlet to the control valve Then remove the burner door to gain access to the above listed components SparkIgniterDoesNotLightPilot Withairinthegasli...

Страница 11: ...Push in gas control knob slightly and turn clock wise to OFF Do not force 5 Replace control access panel lower front panel LIGHTING INSTRUCTIONS 1 STOP Read the safety information above 2 Set the thermostat to lowest setting 3 Turn off all electric power to the appliance 4 Remove control access panel lower front panel 5 Turn gas control knob clockwise to OFF 6 Wait ten 10 minutes to clear out any ...

Страница 12: ...e any part of the control system and any gas control which has been under water 1 STOP Read the safety information above 2 Set the thermostat to lowest setting 3 Turn off all electric power to the appliance 4 This appliance is equipped with an ignition device which automatically lights the pilot Do not try to light the pilot by hand ON OFF IGNITOR CONTROL GAS FLOW GAS VALVE SHOWN IN OFF POSITION H...

Страница 13: ...5 Minute Retry Delay 3 Second Flame Failure Recycle Delay YES YES YES NO Pilot Valve Ignition OFF Wait for Flame Signal to Disappear 1 Ignitor will turn OFF about 30 seconds into the trial for ignition if the pilot flame has not lit It will turn back ON for the final 30 seeonds of the 90 second trial for ignition The pilot valve will be energized during the entire trial for ignition This is normal...

Страница 14: ... Trial Cycle Thermostat OFF and Back ON Main Burner Lights Replace SmartValve Control Check Transformer and Line Volt Supply Check that Pilot Flame Makes Good Contact with Pilot Burner Flame Rod Check for Good Electrical Connection Through the Pilot Tubing If Both of the Above are Good Replace Igniter Flame Rod Measure Voltage Between 24V Hot and 24V Common Leads to SmartValve Control Must Measure...

Страница 15: ...1 BURNER 3 REQUIRED 44 DV 1239 BURNER BRACKET 45 UH 810 TRANSFORMER MOUNTING BRACKET SPP ONLY 45 UH 452 TRANSFORMER MOUNTING BRACKET IP ONLY 46 R 1995 TRANSFORMER SPP ONLY 46 8720100 TRANSFORMER IP ONLY 47 UH 451 JUNCTION BOX COVER 48 DV 572 JUNCTION BOX 49 872056 BUSHING 50 872053 CORD SET 51 8720148 BUSHING 52 DV 1215 BOTTOM PLATE 53 R 3034 PILOT NAT SPP ONLY 53 R 3035 PILOT LPG SPP ONLY 54 GWT ...

Страница 16: ...Page 16 R 3122 Empire Comfort Systems Inc Nine Eighteen Freeburg Ave Belleville Illinois 62222 0529 ...

Отзывы: