background image

TECHNICAL GUIDE

Echelon 

MODELS: FC8V*DH/LC8V*DH

GAS-FIRED
HIGH EFFICIENCY VARIABLE SPEED
DOWNFLOW/HORIZONTAL FURNACES
STANDARD & Low NOx 

NATURAL GAS
57 - 120 MBH INPUT

Due to continuous product improvement, specifications 
are subject to change without notice.

Visit us on the web at www.york.com for the most 
up-to-date technical information.

Additional rating information can be found at 
www.gamanet.org.

EFFICIENCY
RATING
CERTIFIED

ISO 9001

Certified Quality

Management System

246801-CTG-C-0407

FOR DISTRIBUTION USE ONLY - NOT TO BE USED AT POINT OF RETAIL SALE

DESCRIPTION

These high efficiency, compact units employ induced com-
bustion, reliable hot surface ignition and high heat transfer
tubular heat exchangers. The units are factory shipped for
installation in downflow or horizontal applications.
These furnaces are designed for residential installation in a
basement, closet, alcove, attic, recreation room or garage
and are also ideal for commercial applications. All units are
factory assembled, wired and tested to assure safe depend-
able and economical installation and operation.
These units are Category I listed and may be common
vented with another gas appliance as allowed by the
National Fuel Gas Code ANSI Z223.1 (latest edition).

WARRANTY

20-year limited warranty on the heat exchanger.
10-year heat exchanger warranty on commercial applica-
tions.
5-year limited parts warranty.

FEATURES

Two stage heating operation includes:
- Two stage gas valve
- Two stage inducer operation
- Two speed blower operation

• Provides increased comfort level & very quiet unit opera-

tion.

• Field selectable delay timer allows two stage operation w/

single stage thermostat.

• Acoustically insulated blower compartment for reduced 

blower sound level.

• Compact, easy to install, ideal height 40” cabinet.
• Blower-off delay for cooling SEER improvement.
• Easy to connect power/control wiring.
• Built-in, high level self diagnostics with fault code display.
• Low unit amp requirement for easy replacement applica-

tion.

• Integrated control module for reliable, economical opera-

tion.

• Electronic Hot Surface Ignition saves fuel cost with 

increased dependability and reliability.

• Induced combustion system with inshot main burners for 

quiet, efficient operation.

• 100% shut off main gas valve for extra safety.
• Variable Speed ECM with large, quiet blower.

EcoTrak

Variable speed airflow profiles with ECM control 

allows dealer to customize comfort settings based on 
regional location.

• 24V, 40 VA control transformer and blower relay supplied 

for add-on cooling.

• Hi-tech tubular aluminized steel primary heat exchanger.
• Timed on, adjustable off blower capability for maximum 

comfort

• Easy access from front of unit for cleaning, maintenance, 

or service.

• Independent door removal for greater durability and ease 

of access.

• Low NOx models have been designed to meet specific 

code requirements.

• Low NOx models may not be converted to propane unless 

screens are removed.

Summary of Contents for FC8V DH Series

Page 1: ...ons 5 year limited parts warranty FEATURES Two stage heating operation includes Two stage gas valve Two stage inducer operation Two speed blower operation Provides increased comfort level very quiet unit opera tion Field selectable delay timer allows two stage operation w single stage thermostat Acoustically insulated blower compartment for reduced blower sound level Compact easy to install ideal ...

Page 2: ... L C8V100C16DH11 1600 C 21 19 3 4 18 1 2 13 1 2 F L C8V100C20DH11 2000 C 21 19 3 4 18 1 2 13 1 2 F L C8V120C20DH11 2000 C 21 19 3 4 18 1 2 13 1 2 RATINGS PHYSICAL ELECTRICAL DATA MODEL Input High Low Output High Low Nominal Airflow Cabinet Width Total Unit Amps AFUE Air Temp Rise MBH MBH CFM In F F L C8V060A12DH11 57 42 46 34 1200 14 1 2 9 0 80 0 20 50 F L C8V080B16DH11 80 59 64 48 1600 17 1 2 12 ...

Page 3: ...0 C A 1200 780 1200 780 D A 1260 819 1260 819 C C 1080 702 1080 702 D C HIGH LOW HEAT CFM F L C8V060A12DH11 F L C8V080B16DH11 Jumper Settings High Low High Low Heat Tap ADJ Tap 1350 1013 1900 1425 A Any 1250 938 1750 1313 B Any 1150 863 1650 1238 C Any 1050 788 1400 1050 D Any F L C8V080C16DH11 F L C8V100C16DH11 Jumper Settings High Low High Low Heat Tap ADJ Tap 1900 1425 2100 1575 A Any 1750 1313...

Page 4: ...C8V060A12DH11 F L C8V080B16DH11 JUMPER SETTINGS CFM CFM High Low High Low HEAT Tap ADJ Tap 1350 1013 1900 1425 A Any 1250 938 1750 1313 B Any 1150 863 1650 1238 C Any 1050 788 1400 1050 D Any F L C8V100C16DH11 F L C8V100C20DH11 JUMPER SETTINGS CFM CFM High Low High Low HEAT Tap ADJ Tap 2100 1575 2100 1575 A Any 2000 1500 2000 1500 B Any 1800 1350 1800 1350 C Any 1700 1275 1700 1275 D Any F L C8V12...

Page 5: ...ual pressure drop rat ings for each filter type vary between filter manufacturer All filters must be high velocity cleanable type FILTER SIZES Cabinet Size Top Return in Top Return cm A 2 14 x 20 2 35 6 x 50 8 B 2 14 x 20 2 35 6 x 50 8 C 2 14 x 20 2 35 6 x 50 8 FILTER PERFORMANCE PRESSURE DROP INCHES W C AND KPA Airflow Range Minimum Opening Size Filter Type Disposable Washable Fiber Pleated CFM i...

Page 6: ... Pa and divide this by 0 1 w c 25 Pa 0 68 170 Pa 0 60 150 Pa 0 08 20 Pa 0 08 20 Pa 0 1 25 Pa 0 8 Multiply this by 2 to obtain the percentage reduction in air flow 0 8 x 0 02 0 016 Multiply percentage reduction in airflow by the airflow in the table to obtain the airflow reduction 0 016 x 1400 39 6 m3 min 22 0 6 m3 min Subtract airflow reduction value from airflow in the table to obtain actual airf...

Page 7: ...e Cool Y1 First Stage Cool C 24 Volt Common C 24 Volt Common THERMOSTAT Y First Stage Cool Y2 Second Stage Cool W2 Second Stage Heat G Fan R 24 Volt Hot W First Stage Heat Y1 First Stage Cool R 24 Volt Hot Y Y2 Single Second Stage Cool Y2 Second Stage Cool W2 Second Stage Heat G Fan Y2 Second Stage Cool E W1 First Stage Heat RC 24 Volt Hot Cool XFMR THERMOSTAT 24V HUMIDIFIER Optional X L Malfuncti...

Page 8: ...nction Light X L Malfunction Light X L Malfunction Light O B Reversing Valve O Reversing Valve Energized in Cool O Reversing Valve Energized in Cool O Reversing Valve Energized in Cool Y2 Second Stage Heat Cool DHM Dehumidistat HUM Dehumidification Open on Humidity Rise Y2 Second Stage Heat Cool Y2 Second Stage Heat Cool Y2 Second Stage Heat Cool Y 2 AUX Auxiliary Heat E W1 First Stage Auxiliary H...