background image

40397-1-0719

Page 5

IMPORTANT SAFETY INFORMATION

INSTALLER:

 Leave these instructions with the owner. For 

Installation In Solid Fuel Burning Fireplaces. Do not burn wood 

or solid fuels in a fireplace where a decorative gas log set is 

installed. This appliance is for installation only in a solid fuel 

burning fireplace, masonry fireplace or manufactured fireplace.

WARNING

Before installing in a solid fuel burning fireplace, the chimney 

flue and firebox must be cleaned of soot, creosote, ashes 

and loose paint by a qualified chimney cleaner.

WARNING

Do not allow fans to blow directly into or at the fireplace. 

Avoid any drafts that alter burner flame patterns.

WARNING

Do not use a blower insert, heat exchanger insert or other 

accessory not approved for use with this appliance.

DANGER

Any modification to this gas log set or to controls can be 

dangerous. Improper installation or use of the gas log set 

can cause serious injury or death from fire, burns, explo

-

sion or carbon monoxide poisoning.

WARNING

Do not operate this burner with glass doors closed. 

• 

Installation and repair must be done by a qUALIFIED 

SERVICE PERSON. The appliance should be inspected 

before use and at least annually by a qualified service 

person. More frequent cleaning may be required due to 

excessive lint from carpeting, bedding materials, etc. It 

is imperative that control compartments, burners and 

circulating air passageways of the appliance be kept clean.

• 

Dot not place clothing or other flammable material on or near 

the appliance.

• 

Do not place trash or other articles on the log set during 

operation.

• 

Do not put anything around the fireplace that will obstruct the 

flow of ventilation air.

• 

Do not use this appliance if any part has been under water. 

Immediately call a qualified service technician to inspect the 

appliance and to replace any part of the control system and 

any gas control which has been under water.

• 

Do not use thermostats on vented burner applications 

 

Keep the appliance area clear and free from combustible 

material, gasoline and other flammable vapors and liquids.

• 

Keep burner and control compartment clean. 

• 

A yearly examination and cleaning of the venting system 

of the solid-fuel burning fireplace must be performed by a 

qualified agency.

• 

Make a periodic visual check of pilot and burners. Clean and 

replace damaged parts.

• 

Alert children and adults to the hazards of high surface 

temperatures and caution them to stay away to avoid burns 

or clothing ignition.

• 

Carefully supervise young children when they are in the 

same room as the appliance.

• 

During manufacture, this burner is treated with certain oils, 

films and bonding agents. These substances are not harmful 

but may produce smoke and odors as they burn off during 

initial operation of the fireplace. This is normal. Open a 

window during the initial bake out period. 

• 

Proper installation, burner pan location and log placement 

is important to achieve optimum look and performance of 

your gas log set. Follow the log assembly sequence for 

proper operation.

• 

Do not operate this log set with glass doors in the closed 

position. A fireplace screen must be in place when the log 

set is burning. Adequate combustion air must be provided for 

proper venting. All flames should go up and out the top of the 

firebox into the flue vent. If any flames float or curl forward 

into the room do not operate appliance. Check for an open 

flue and adequate combustion air into the room. A damper 

clamp must be installed on the firebox damper to maintain 

an open flue. See page 10.

• 

Young children must be carefully supervised when they are 

in the same room as the gas log while in operation. Do not 

place stockings, clothing or any flammable material above or 

near the fireplace.

• 

Do not substitute or use materials other than those supplied 

for use with the log set.

WARNING

Follow all gas leak check procedures in this manual, prior 

to operation.

WARNING

Fuels used in gas or oil-fired appliances, and the products 

of combustion of such fuels, contain chemicals known to 

the State of California to cause cancer, birth defects, and/

or other reproductive harm. This warning is issued pursu-

ant to California Health & Safety Code Sec. 25249.6.  

DO NOT ATTEMPT TO DISCONNECT THE GAS OR ANY GAS 

FITTING WHILE THIS APPLIANCE IS IN OPERATION.
NEVER leave the decorative gas log set unattended while in 

operation.
NEVER allow children to operate this decorative gas log set.

NEVER place hands or fingers on the front-edge of this 

decorative gas log set.

NEVER use liquid propane gas in a natural gas unit, or natural 

gas in a liquid propane unit.

DO NOT use solid-fuel or lighter fluid in any decorative gas log set.

Any safety screen or guard removed for servicing an appliance 

must be replaced prior to operating the appliance.

Содержание BFE2124MTN

Страница 1: ...is installed DANGER If not installed operated and maintained in accordance with the manufacturer s instructions this product could expose you to substances in fuel or from fuel combustion which can cause death or serious illness WARNING FIRE OR EXPLOSION HAZARD If the information in this manual is not followed exactly a fire or explosion may result causing property damage personal injury or loss o...

Страница 2: ...ns 9 Introduction 10 Fireplace Preparation 10 Gas Supply 11 12 Installation 13 14 Door Operation 15 Lighting Instructions 16 Pilot And Main Burner Flame Characteristics 17 Remote Operation 18 Switch Operation 19 Control System Specifications 20 22 Maintenance And Service 23 Troubleshooting 24 BFR Parts List And Exploded View 25 Master Parts Distributor List 26 How To Order Repair Parts 26 Warranty...

Страница 3: ... codes in any way Authorities having jurisdiction should be consulted before installation Follow all local codes regarding installation combustion and ventilation air or in the absence of local codes follow the National Fuel Gas Code ANSI Z223 1 U S installation or CAN CGA B149 Installation Code Canada installation and with ANSI Z21 60 Decorative Vented Appliances for Solid Fuel Burning Fireplaces...

Страница 4: ...24 30 RN Index No Description Quantity Supplied BFR2124 BFR30 1 Burner Assembly 1 1 2 Control Module Assembly 1 1 3 Battery Holder 1 1 4 Energizer Lithium Battery 4 4 5 Remote 1 1 6 Flexline 1 1 7 Rockwool 1 1 8 Lava Rock 2 2 NS Fiber Heat Sink 1 1 See Parts Lists on page 22 for ordering replacement parts Do not order batteries bolts screws washers or nuts They are standard hardware items and can ...

Страница 5: ...pilot and burners Clean and replace damaged parts Alert children and adults to the hazards of high surface temperatures and caution them to stay away to avoid burns or clothing ignition Carefully supervise young children when they are in the same room as the appliance During manufacture this burner is treated with certain oils films and bonding agents These substances are not harmful but may produ...

Страница 6: ...tion service or main tenance can cause property damage personal injury or loss of life Refer to the owner s information manual provided with this appliance Installation and service must be performed by a qualified installer service agency or the gas supplier GAS WARNING ODOR If a gas leak happens you should be able to smell the gas because of the odorant put in the propane gas That s your signal t...

Страница 7: ...as Your local pro pane gas dealer can give you a Scratch and Sniff pamphlet Use it to find out what the propane odor smells like If you suspect that your propane gas has a weak or abnormal odor call your propane gas dealer If you are not qualified do not light pilot lights perform service or make adjustments to appliances on the propane gas system If you are qualified consciously think about the o...

Страница 8: ...entilation air must conform with the National Fuel Gas Code ANSI Z223 1 NFPA54 Canadian Installation Code CAN CGA B149 Available from the American National Standards Institute Inc 11 West 42nd St New York N Y 10018 High Altitude Installation When installing this unit at an elevation above 2000 feet in the United States it may be necessary to decrease the input rating by changing the existing burne...

Страница 9: ...65 000 PROPANE CONVERSION KIT Burner Model Valve Type Kit Number BFE2124MTN Variable CKV121 BFE30MTN Variable CKV122 NOTE The air shutter setting for all models is 1 16 open PRODUCT SPECIFICATIONS Determining the Correct Burner Size for Your Fireplace MINIMUM FIREPLACE DIMENSIONS FACTORY BUILT FIREPLACES Chimney Height Minimum of 10 Feet Burner Model Log Set Size Rear Width A Depth B Front Width C...

Страница 10: ...eparation INTRODUCTION Introduction Always consult your local Building Department regarding regu lations codes or ordinances which apply to the installation of a vented decorative gas log set in a solid fuel burning fireplace This appliance is only for use with the type of gas indicated on the rating plate Instructions to Installer 1 Installer must leave instruction manual with owner after install...

Страница 11: ...complete all solution should be cleaned off On unexposed connections a pressure test should be made Never use an exposed flame to check for leaks Appliance must be disconnected from piping at inlet of control valve and pipe capped or plugged for pressure test Never pressure test with appliance connected control valve will sustain damage A gas valve and ground joint union should be installed in the...

Страница 12: ...the procedures results in pressures in excess of 1 2 psig 14 in w c 3 5 kPa on the appliance gas valve it will result in a hazardous condition Checking Manifold Pressure PropaneGasmodelswillhaveamanifoldpressureofapproximately 10 0 in w c 2 49kPa at the pressure regulator outlet with the inlet pressure to the pressure regulator from a minimum of 10 8 in w c 2 69kPa for the purpose of input adjustm...

Страница 13: ...e for the first time IMPORTANT This appliance must be installed only in a solid fuel burning fireplace which contains a working flue and is constructed of non combustible materials IMPORTANT Never carry the burner in such a way that causes the Control Module or Battery Holder to dangle by their connecting wires You must secure the gas burner to the fireplace floor If not the entire unit may move w...

Страница 14: ...wool 061019 Figure 8 11 Place the lava rock around the burner assembly Figure 9 STOP The LKF Fiber Log Set and LPR2430 Refractory Log Set are the only two log sets which are approved for use on these burners DO NOT substitute a different log set or deviate from the log placement sequence Refer to the instructions packaged with your Decorative Gas Logs 6 Remove all contents from the Decorative Gas ...

Страница 15: ...RS CORRECT DOOR POSITION WHEN OPERATING THE FIREPLACE Figure 11 PARTIALLY OPEN DOORS INCORRECT DOOR POSITION WHEN OPERATING THE FIREPLACE WARNING DO NOT operate the fireplace with the doors partial ly open or closed Operating the fireplace with the doors partially open or closed creates a hazardous situation Partially open doors can cause sooting on front of the fireplace Closed doors can cause th...

Страница 16: ...ING smell all around the appliance area for gas Be sure to smell next to the floor because some gas is heavier than air and will settle on the floor WHAT TO DO IF YOU SMELL GAS Do not try to light any appliance Do not touch any electrical switch do not use any phone in your building Immediately call your gas supplier from a neighbor s phone Follow the gas supplier s instructions If you can t reach...

Страница 17: ...lot Flame Pattern Figure 13 If pilot flame pattern is incorrect See Troubleshooting page 21 Main Burner Flame Pattern The main burner flame will be yellow with a blue base Main Burner Flame Ignition and Extinction When the main burner is ignited it will take a few seconds for the full flame pattern to develop When the main burner is extinguished it will take a few seconds for the flames to disappe...

Страница 18: ...press any button on the transmitter A beep at the module indicates the transmitter s code has been accepted The microprocessor that controls the security code matching procedure is controlled by a timing function If you are unsuccessful in matching the security code on the first attempt wait 1 2 minutes before trying again this delay allows the microprocessor to reset its timer circuitry and try u...

Страница 19: ...e left of the burner must be set to ON 2 With the ON OFF or REMOTE switch set to ON the burner lighting sequence will initiate 3 The flame height will default to high for five seconds before responding to the HI LO switch on the module 4 After five seconds the HI LO switch will control the flame height The user can select between HI and LO Variable flame control is only available when using the re...

Страница 20: ...thermore this event will NOT trigger the re ignition safety fault counter If the thermocouple voltage does not recover to above FLAME TRUE after the 10 second timer period expires the main flame will turn OFF and the control will attempt to re establish the pilot flame again with the normal 60 second trial period Furthermore this event WILL trigger the re ignition safety fault counter 3 attempts w...

Страница 21: ...tch in ON position 2 High Position contacts closed Control will operate step motor on gas valve to Main Flame On High position 3 Low Position contacts open Control will operate step motor on gas valve to Low Flame position LEARN 1 Press and release to open LEARN window the control is ready to accept a transmitter security code 2 LEARN window will remain open for 60 seconds 3 Control will learn up ...

Страница 22: ...onds 2 Description of Fault Internal temperature has exceeded 170 deg F 3 Action The module will operate the step motor in the gas valve to the OFF position 4 How to Clear Module s internal temperature must cool to below 160 deg F and then press OFF button Communication Safety Note This feature is only available when transmitter includes an LCD screen 1 Error Code One short beep every 4 seconds 2 ...

Страница 23: ...rush the soot off with a brush Do not use water or soot cleaners B When the logs are cold remove logs from burner Take logs outside and remove soot with an air hose Refer to Installation Instructions supplied with logs for re installa tion information Cleaning Keep the control area logs and burner area surrounding the logs clean ThelogscangetveryhoT Handleonlywhencool Always keep the appliance are...

Страница 24: ... Replace valve Burner lights but does not stay lit while pilot remains on Low gas pressure Check gas supply pressure Faulty valve Replace valve Faulty pilot or thermocouple Replace Safety pilot Clogged or dirty burner ports Clean burner ports Burner and pilot light but will not stay on Low gas pressure Check gas supply pressure Not enough fresh air for pilot Open door or window ventilate Faulty va...

Страница 25: ...1 NS V Wire 36 Inch BFE2124 BFE30 10 R12710 Pilot With Thermocouple Convertible BFE2124 BFE30 11 R1499 Grommet Rubber BFE2124 BFE30 12 40372 Tube Assembly BFE30 12 40373 Tube Assembly BFE2124 13 R11978 Venturi BFE2124 BFE30 14 R11977 Venturi Gasket BFE2124 BFE30 15 P273 Orifice 22 BFE2124 NG 15 P314 Orifice 2 25mm BFE2124 LP 15 P325 Orifice 12 BFE30 NG 15 P285 Orifice 39 BFE30 LP 16 P253 Orifice F...

Страница 26: ...hase and can be ordered by your Service Person or Dealer Proof of purchase is required for warranty parts All parts listed in the Parts List have a Part Number When ordering parts first obtain the Model Number and Serial Number from the name plate on your equipment Then determine the Part Number not the Index Number and the Description of each part from the following illustration and part list Be ...

Страница 27: ...tion Duties of the Owner The appliance must be installed by a qualified installer and operated in accordance with the instructions furnished with the appliance A bill of sale cancelled check or payment record should be kept to verify purchase date and establish warranty period Ready access to the appliance for service What Is Not Covered Damages that might result from the use misuse or improper in...

Страница 28: ...www empirecomfort com Empire Comfort Systems Inc Belleville IL If you have a general question about our products please e mail us at info empirecomfort com If you have a service or repair question please contact your dealer ...

Отзывы: