CG Drives & Automation 01-6048-01r3
Technical Data
47
6.
Technical Data
EMX-B15
EMX-B25
EMX-B35
Output data
Rotation speed
4 - 500 rpm
Rated tourque
0.8 Nm @ 500 rpm
1.3 Nm @ 300 rpm
2.0 Nm @ 500 rpm
3.3 Nm @ 300 rpm
3.0 Nm @ 500 rpm
5.0 Nm @ 300 rpm
Continuous Power
42 W
100 W
160 W
Starting & max tourque
1.8 Nm
4.8 Nm
7.5 Nm
Direction of rotation
Selectable
Purging mode
Built-in function
Motor protection
Built-in function
Alarm output
Alternating contact, max 3 A, 230 VAC or 24 VDC
Input DATA
Mains supply VOLTAGE
230 VAC +10/ -15%, 50/60 Hz
Maximum Fuse
4 A
6 A
6 A
Maximum current
1.0 A
3.0 A
3.0 A
Control signal
0-10 V
DC
, 2 - 10 V
DC
, 0 - 20 mA, 4-20 mA,
10 k
Ω
potentiometer.
General DATA
Protection class
IP 54
Weight, control unit
0.5 kg
1.5 kg
1.5 kg
Weight, motor
4.5 kg
6.0 kg
8.0 kg
Ambient temperature
-40° to +40°C
EMC, emission
EN61800-3
Standards
EN 61000-6-3:2004/6100-6-4, A1:2012EMC- product standard
EN 6100-6-2 EMC emission
EN 61800-5-1:2007 Safety requirements – Electrical, thermal and
energy
Cable type
Motorcable: Insulated with 3 individually isolated leads- 0.5 mm
2
+
PE- 2.5 mm
2
with pin type crimp lugs.
Sensor cable: 5 leads- 0.75 mm
2
with pin type crimp lugs.
Cable length - 2500mm.
Cable glands
2 pcs M12 glands
(Motor)
1 pc M20 and
4 pcs M16 glands
(Control unit)
2 pcs M12 glands (Motor)
2 pcs M20 and 3 pcs M16 glands
(Control unit)
Содержание EMX-B
Страница 1: ...Emotron EMX B Drive system for rotary heat exchangers Instruction manual English...
Страница 2: ......
Страница 8: ...4 CG Drives Automation 01 6048 01r3...
Страница 16: ...12 Description CG Drives Automation 01 6048 01r3...
Страница 56: ...52 Technical Data CG Drives Automation 01 6048 01r3...
Страница 58: ...54 Appendix CG Drives Automation 01 6048 01r3 7 2 Front label Fig 17 Front label...
Страница 59: ......