5
1. Move the weather station to another location and try to detect DCF signal again.
2. Check the distance of the clock from the sources of interference (computer monitors or television
sets). It should be at least 1.5 to 2 m during the reception of signal.
3. When receiving DCF signal, do not place the weather station near metal doors, window frames
and other metal structures or objects (washing machines, dryers, refrigerators, etc.).
4. In reinforced concrete structures (cellars, high-rise buildings, etc.), DCF signal reception is
weaker, depending on the conditions. In extreme cases, place the weather station close to a
window toward the transmitter.
Reception of the DCF 77 radio signal is affected by the following factors:
• thick walls and insulation, basements and cellars,
• inadequate local geographical conditions (these are difficult to assess in advance),
• atmospheric disturbances, thunderstorms, electrical appliances with no interference elimination,
television sets and computers, located near the DCF receiver.
Manual Settings
All changes in values are made using buttons and .
After setting the desired value and not pressing any other buttons, the set values will automatically
save and the display will switch to the main screen.
Setting Time, Date and Time Zone
1. Short-press the button
2. Press the button for 3 seconds and use the and
buttons to set the following values:
time zone, calendar language (ENG, GER, FRE, ITA, DUT, SPA, DAN), year, date format, month,
day, 12/24 h time format, hour, minute, second.
3. Confirm the set value by pressing the button; holding the arrow keys speeds up settings.
Alarm Settings
2 alarms can be set on the weather station.
1. Short-press the button twice
2. Press the button for 3 seconds and use the arrows to set the alarm hour and minute.
3. Confirm the set value by pressing ; holding the arrow keys speeds up settings.
Alarm Activation/Deactivation/Snooze
Repeatedly pressing the button activates alarm 1 (AL1); alarm 2 (AL2); or both alarms at the same
time (AL1, AL2); or deactivates the alarms.
You can postpone (snooze) the alarm by 5 minutes by pressing the
button. After pressing, the
icons will start flashing.
Turn off the alarm by pressing
. After pressing, the
icons will stop flashing
and only
will remain on the screen. The alarm will activate again the next day.
Setting Altitude and Atmospheric Pressure
The station shows atmospheric pressure in hPa or inHg and keeps a history of pressure readings
for the last 12 hours.
To achieve more accurate calculation of pressure values, it is advised to manually set the altitude
for the place where the weather station is being used.
1. Short-press the button three times
2. Press the button for 3 seconds and use the arrows to set altitude between -90 m to +1,990 m
(10 m increments).
3. Pressing the button switches between M/hpa and Ft/inHg units.
4. Short-press the button to quit settings.
Setting Temperature Limits for Maximum and Minimum Temperature
Temperature limits can be set independently for up to 3 outdoor temperature sensors.
When minimum or maximum temperature limit is activated, the
(min) or
(max) icon will
appear on the screen and disappear after deactivation.