OUTPUTS

CHANNEL-1 PID CONTROL OUT

Channel-1 PID Control Output Status 

44

Address

00001

CHANNEL-2 PID CONTROL OUT

Channel-2 PID Control Output Status

00002

CHANNEL-3 PID CONTROL OUT

Channel-3 PID Control Output Status

00003

CHANNEL-4 PID CONTROL OUT

Channel-4 PID Control Output Status

00004

-

00005

CHANNEL-1 ALARM OUT

Channel-1 Alarm Output Status

00006

CHANNEL-2 ALARM OUT

Channel-2 Alarm Output Status

00007

CHANNEL-3 ALARM OUT

Channel-3 Alarm Output Status

00008

CHANNEL-4 ALARM OUT

Channel-4 Alarm Output Status

00009

GENERAL ALARM OUT

General Alarm Output Status

00010

Note-2: 

Process Input values can be readed with modbus function-4 (read input register). Because of the 

process values are displayed on LCD screen with point, the reading values  from  modbus  will  be  10  times 
more than the real values. 

Note-1: 

Outputs status are can be readed with modbus function-1 (read coils).

Device’s response for modbus function-1 is always 2 byte data although the modbus function request less 
than 9 outputs port.       

  8.1. PID Control and Alarm Output Modbus Addresses

  8.2. Process Input Values Modbus Addresses

  8. Modbus Addresses

Unit

-

-

-

-

-

-

-

-

-

-

-

PROCESS INPUTS

CHANNEL-1 PROCESS VALUE

Channel-1 Process Value

Address

30001

CHANNEL-2 PROCESS VALUE

Channel-2 Process Value

30002

CHANNEL-3 PROCESS VALUE

Channel-3 Process Value

30003

CHANNEL-4 PROCESS VALUE

Channel-4 Process Value

30004

Unit

O

C

O

C

O

C

O

C

Содержание PID QUADRO EPLC9600

Страница 1: ...rol parameter which can be adjust for each day of week or via front panel buttons or via digital inputs Adjustable temperature offset for each channel 3 Different alarm types for each channel High Low...

Страница 2: ...ained Operation Also in these sections there are warnings to prevent serious injury while doing the physical and electrical mounting or using the device Explanation of the symbols which are used in th...

Страница 3: ...ERS 6 1 DEFINETION OF FRONT PANEL 6 2 MAIN OPERATION SCREEN DEFINETION 6 3 ACCESSING TO THE OPERATOR PARAMETER PAGES 6 4 ACCESSING TO THE TECHNICIAN PARAMETER PAGES 6 5 ACCESSING TO THE CALIBRATION PA...

Страница 4: ...EC The Low Voltage Directive 2004 108 EC The Electromagnetic Compatibility Directive has been designed and manufactured to the following specifications EN 61000 6 4 2007 EMC Generic Emission Standard...

Страница 5: ...ich they are used are below Application Fields Applications Glass Heating Plastic Baking Ovens Petro Chemistry Incubators Textile Storages Automative Storages Machine production industries etc etc 1 P...

Страница 6: ...the standards A 1 Supply Voltage A 2 9 Customer 100 240V V 15 10 50 60Hz 24VV 15 10 50 60Hz 24VZ 15 10 1 3 Warranty EMKO Elektronik warrants that the equipment delivered is free from defects in mater...

Страница 7: ...eep the power off until all of the wiring is completed so that electric shock and trouble with the unit can be prevented Never attempt to disassemble modify or repair this unit Tampering with the unit...

Страница 8: ...9600 PID QUADRO Front View and Dimensions of 96 mm 3 78 inch 96 mm 3 78 inch 12 1 mm 0 47 inch 84 mm 3 31 inch Maximum 15 mm 0 59 inch Front Panel IP65 protection NEMA 4X Panel surface maximum thickne...

Страница 9: ...2 3 Panel Cut Out 9 129 mm 5 08 inch min 92mm 3 62 inch 92mm 3 62 inch 129 mm 5 08 inch min...

Страница 10: ...etal panel care should be taken to avoid injury from metal burrs which might be present The equipment can loosen from vibration and become dislodged if installation parts are not properly tightened Th...

Страница 11: ...re that device will not fall while doing the montage 2 6 Installation Fixing Clamp The unit is designed for panel mounting 1 Insert the unit in the panel cut out from the front side 2 Insert the mount...

Страница 12: ...e unit against damage and to prevent failure Keep the power off until all of the wiring is completed so that electric shock and trouble with the unit can be prevented 3 Electrical Wirings 3 1 Terminal...

Страница 13: ...NERAL ALARM OUT 5 x 5A 250VV USB 2 0 COMMUNICATION ETHERNET OR RS485 COMMUNICATION For Channel 1 2 3 and 4 PID Control Outputs Relay Outputs i i For Channel 1 2 3 and 4 Alarm Outputs and General Alarm...

Страница 14: ...supply voltage input Power supply switch and fuse must be put to a place where user can reach easily Power supply switch must be two poled for seperating phase and neutral On Off condition of power s...

Страница 15: ...t 2000V V Relay Outputs Digital Inputs 2000V V 2000V V 2000V V 14 15 AIN1 AIN2 AIN3 AIN4 500V V 2000V V 2000V V AIN2 AIN1 AIN3 AIN4 500V V 2000V V 2000V V AIN3 AIN1 AIN2 AIN4 500V V 2000V V 2000V V AI...

Страница 16: ...puter 9 Pin DCON connection Cable Lenght must be max 12 meters for 9600 baud rate 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 TX NA RX GND NA NA 4 Cable Connection...

Страница 17: ...used Cable lenght can be maximum 1000 meters in 9600 baud rate When baud rate increases cable lenght must be decreased 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30...

Страница 18: ...and entering the symbol character for string type variables in variable value changing screen DOWN BUTTON This button is used to decrement the digit which cursor is show of variable in variable value...

Страница 19: ...EEN 1 Press escape button for returning main operation screen 1 i i MAIN OPERATION SCREEN 2 Device Working Mode 6 2 Main Operation Screens Definition If more than one alarm messages is present each al...

Страница 20: ...he password parameter Minimum Maximum 0 9999 0 0 Press enter button for accessing to password entering screen Enter the operator parameter section password with cursor lef right up and down buttons OP...

Страница 21: ...ge the parameter value with cursor lef right up and down buttons Press number 1 2 3 or 4 buttons for accessing the relevant channel s parameter screen OPERATOR PARAMETER SCREEN CHANNEL 2 PARAMETERS Ot...

Страница 22: ...r button for accessing to password entering screen Enter the technician parameter section password with cursor lef right up and down buttons TECHNICIAN PARAMETERS SECTION PASSWORD ENTERING SCREEN TECH...

Страница 23: ...ed for 20 seconds in technician parameters section device turns to main operation screen automatically Press number 1 2 3 or 4 buttons for accessing the relevant channel s parameter screen Press down...

Страница 24: ...tton for accessing next parameter page press up button for accessing previous parameter page Press up button for accessing previous parameter page press escape button for return to main operation scre...

Страница 25: ...Maximum 0 9999 0 CALIBRATION PASSWORD MAIN OPERATION SCREEN CALIBRATION PARAMETERS SECTION PASSWORD SCREEN Press right or left button for selecting the password parameter Press enter button for access...

Страница 26: ...y observed Parameter CHANNEL 1 PROCESS SET Address 42030 CHANNEL 2 PROCESS SET 42042 CHANNEL 3 PROCESS SET 42054 CHANNEL 4 PROCESS SET 42066 Parameter Address CHANNEL 1 ALARM SET 42078 CHANNEL 2 ALARM...

Страница 27: ...put 100 0 0 OUT MAXIMUM PID Maximum Control Output 100 sec sec sec 1 150 1 0 100 Min Max Unit DERIVATIVE PID derivative value for selected channel is can be adjusted according to this parameter It can...

Страница 28: ...CHANNEL 2 OUT MINIMUM 42049 CHANNEL 3 OUT MINIMUM 42061 CHANNEL 4 OUT MINIMUM 42073 Parameter CHANNEL 1 OUT MAXIMUM Address 42038 CHANNEL 2 OUT MAXIMUM 42050 CHANNEL 3 OUT MAXIMUM 42062 CHANNEL 4 OUT...

Страница 29: ...nished without any problem device saves new PID parameters to memory and the tune parameter value is to 0 automatically If parameter value 0 Tune off 1 Auto tune Limit CycleTuning operation 2 Self tun...

Страница 30: ...39 CHANNEL 2 SOFT START 42051 CHANNEL 3 SOFT START 42063 CHANNEL 4 SOFT START 42075 Parametre CHANNEL 1 ALARM TYPE Address 42079 CHANNEL 2 ALARM TYPE 42083 CHANNEL 3 ALARM TYPE 42087 CHANNEL 4 ALARM T...

Страница 31: ...tering to the technician section is defined with this parameter If it is 0 technician section accessed without entering password OPER PASS Password for entering to the operator section is defined with...

Страница 32: ...8 CHANNEL 2 PV OFFSET 42099 CHANNEL 3 PV OFFSET 42100 CHANNEL 4 PV OFFSET 42101 Alarm Hysteresis Parameters Modbus Addresses Alarm Bandwith Parameters Modbus Addresses Proses Offset Value Parameters M...

Страница 33: ...n Channel Names I O PID Operation Type Selection Parameter If parameter value 0 PID function is disabled 1 Heating PID function is selected 2 Cooling PID function is selected PID operation type is sel...

Страница 34: ...and auto eco mode is active for selected day of week then auto eco mode starting minute is determined by this parameter TIME If MODE CONTROL parameter value selected as 3 auto mode control is active...

Страница 35: ...Auto ECO Mode Parameters for THURSDAY THURSDAY ECO MODE SET DIFF 42148 FRIDAY ECO Address 42153 FRIDAY ECO MODE STARTING HOUR 42154 FRIDAY ECO MODE STARTING MINUTE 42155 FRIDAY ECO MODE TIME 42156 Au...

Страница 36: ...0 auto SLEEP MODE is disable for selected day of week 1 auto SLEEP MODE is enable for selected day of week MODE START HOUR If MODE CONTROL parameter value selected as 3 auto mode control is active and...

Страница 37: ...NG MINUTE WEDNESDAY SLEEP MODE TIME Auto SLEEP Mode Parameters for WEDNESDAY THURSDAY SLEEP THURSDAY SLEEP MODE STARTING HOUR THURSDAY SLEEP MODE STARTING MINUTE THURSDAY SLEEP MODE TIME Auto SLEEP Mo...

Страница 38: ...S232 is can be adjusted by this parameter If parameter value ID Modbus communication device ID for RS232 is can be adjusted by this parameter This parameter value is can be adjusted from 1 to 247 exce...

Страница 39: ...by this parameter If parameter value ID Modbus communication device ID for RS485 is can be adjusted by this parameter BAUDRATE Baudrate For RS485 Communication 42110 6 1 2 PARITY Parity For RS485 Comm...

Страница 40: ...mple When the analogue values are recorded on USB file user can be save the recording time on the file Recording time is recorded at the beginning of every lines of file SAMPLE TIME Record time interv...

Страница 41: ...be adjusted by this parameter If DHCP is selected as a enable there is no need to adjust to this parameter if DHCP is selected as a disable then user must adjust this parameter PORT SET Ethernet port...

Страница 42: ...ameter SECOND Second value for RTC time is adjusted by this parameter Min Max Default Unit YEAR Year Value For RTC Time 3000 2010 MONTH Month Value For RTC Time 12 1 Parameter Explanation DAY Day Valu...

Страница 43: ...m Output Process Value Alarm Output SET HYS SET HYS ON OFF Alarm Output Process Value BandAlarm SET SET BAND 2 SET BAND 2 HYS HYS SET Alarm Set value HYS Hysteresis value forAlarm output BAND Bandwidt...

Страница 44: ...Input values can be readed with modbus function 4 read input register Because of the process values are displayed on LCD screen with point the reading values from modbus will be 10 times more than th...

Страница 45: ...Sensor Break Protection Upscale Sampling Time 1400msecs Input Ressistance 10MW Control Forms Programmable P PI PD or PID Relay Output Resistive Load 5A 250VV Electrical Life 100 000 operation Full Lo...

Отзывы: