6.7.4. Page-4 Parameters
Min.
Max.
Default
Unit
CHANNEL-1 CH. NAME Channel-1 Label
Address
42000 - 42004
SENSOR-1
-
-
String
CHANNEL-2 CH. NAME Channel-2 Label
42005 - 42009
SENSOR-2
-
-
String
CHANNEL-3 CH. NAME Channel-3 Label
42010 - 42014
SENSOR-3
-
-
String
CHANNEL-4 CH. NAME Channel-4 Label
42015 - 42019
SENSOR-4
-
-
String
Parameter
Explanation
CHANNEL-1 I/O
Channel-1 Selection
42102
1
0
2
-
CHANNEL-2 I/O
Channel-2 Selection
42103
1
0
2
-
CHANNEL-3 I/O
Channel-3 Selection
42104
1
0
2
-
CHANNEL-4 I/O
Channel-4 Selection
42105
1
0
2
-
Channel
Numbers
Channel Selection
Channel Names
I/O “PID Operation Type Selection Parameter”
If parameter value
0 = PID function is disabled
1 = Heating PID function is selected
2 = Cooling PID function is selected
PID operation type is selected by this parameter. If parameter value is selected as a 0 (PID disabled) then,
PID is not operate, alarm output is not controlled and analogue value for this channel is not recording on
USB file.
,
CH. NAME “
”
Channels label definition
All channels have their own label, is displayed in main operation screen. channel labels is can be adjusted
by this parameter. Channel labels are can be adjusted maximum 10 characters.
If no operation is performed for 20 seconds in technician parameters section, device turns to
main operation screen automatically.