‘Intermed.’sets the code 70, which is the default code for intermediate/split times.
‘Start’ sets the code 0, which resets the internal clock in the emiTags.
‘Finish 1l.’ sets the code 90 and activates loop1.
‘Finish 2l.’ sets the code 248 and activates both loop1 and loop2.
This is the only
choice that uses both loop1 and loop2!
The code used for the ETS2 decides what kind of registration you will get and
which frequency the radio will transmit on. Therefore it is very important to set the
right code. We recommend using the following codes:
Start
-
0
Relay handover
-
66
Registration of penalty loops
-
67
Split time/forewarning
-
70
Finish, single eLine loop
-
90
Finish, double eLine loops
-
248
Backup, finish
-
249
Settings
(main menu - settings)
In the 'Settings'-menu it is possible to change how the ETS2 handles different
input, how it is shown and how the data is transferred to an external device.
Ack
(main menu – settings - ack)
Normally 'Ack' (acknowledgement) should be turned on, which is the default
setting. This means that the emiTags stop resending data after receiving 'Ack'
from the ETS2. Set 'Ack' to off only when the ETS2 is used in combination with
another ETS2.