background image

TB-6559

 Page 4 of 5

© 2013 DESCO INDUSTRIES INC.

Employee Owned

EMIT

 - 3651 Walnut Avenue, Chino, CA 91710 • (909) 664-9980 • Website: 

DescoEMIT.com

2.  Hold the gun approximately six inches from the surface

 

you want to neutralize and blow-off.  Aim the nozzle

 

and hold down the trigger.  The LED on the back of the

 

gun should illuminate.  Typically, static charges are

 

discharged within one second.

3.  Release the trigger when the surface is clean.
If the optional foot switch is installed, you may use either 

the foot switch or gun trigger.

Figure 8: Using the Chargebuster Ion Gun

Maintenance

“All ionization devices will require periodic maintenance for 

proper operation. Maintenance intervals for ionizers vary 

widely depending on the type of ionization equipment and 

use environment. Critical clean room uses will generally 

require more frequent attention. It is important to set-up 

a routine schedule for ionizer service. Routine service 

is typically required to meet quality audit requirements.”  

(ESD Handbook TR 20.20 section 5.3.6.7 Maintenance / 

Cleaning)

CLEANING THE COMPONENTS

1.  Turn off the console and disconnect it from its

 

electrical power and gas supply sources.

2.  Using a cloth moistened with the IPA solution, wipe

 

the exterior surfaces of the console and gun to

 

remove any dirt or dust that may have collected.

3.  Using a swab moistened with the IPA solution,

 

gently clean the emitter points on the gun.

 

Extremely dirty points increase the time needed to

 

discharge static and can affect the ionization

 

balance.

REPLACING THE DISPOSABLE FILTER

EMIT recommends that the disposable filter be changed 

every 3 months or when it begins to look dirty.
1.  Turn power off at the console and disconnect the

 

console from the gas supply.

2.  Hold down the disposable filter release button on

 

the side of the console.

3.  Remove the hose and disposable filter from the

 

console by pulling the textured rubber plug where

 

the hose emerges from the console.  Rocking the

 

plug back and forth can help loosen the filter.  Do

 

not pull the hose itself.

4.  Remove the disposable filter from the hose fitting by

 

depressing the metal release tab on the fitting and

 

pulling off the air filter.

5.  Replace with the new disposable filter by following

 

the procedure in the ASSEMBLY section on page

 

2.

Specifications

Operating Voltage 

120 VAC, 60 Hz (item 50645)

 

230 VAC, 50 Hz (item 50644)

Operating Temperature 

32°F - 104°F (0 - 40°C)

Discharge (±1000V-100V) 

1.0 s @ 6", 30 psi

Cleanroom Class 

Meets ISO 14644-1 Class 4

Console Power 

24 VAC from power adapter

Ion Emission 

Steady-state DC

Emitter Points 

Tungsten emitter points

Audible Noise 

70 dBA @ 1m, 30 psi

Ozone 

<0.005 ppm

Blow-off Force 

41g @ 30 psi;

 

measured @ 3" from a 2" 

 

diameter target

Volumetric Flow Rate 

3.0 SCFM @ 35 psi

 

3.5 SCFM @ 30 psi

 

4.0 SCFM @ 35 psi

Air Hose 

Static-dissipative 

 

polyurethane, 3/8" OD,

 

7' length, 65 psi

Gas Input 

20-65 psi, Clean Dry Air 

 

(CDA) or nitrogen

Gas Connection 

1/4" male industrial 

 

interchange quick connect

Gas Air Filter 

99.9% efficient, 0.1 micron or 

 

larger

Отзывы: