Figure 5: Mounting the console to the mounting plate

Figure 6: Inserting the disposable filter

Choose a location that will be convenient to the work area 

and the gas supply.  The Console takes up very little space 

and is adaptable to a variety of permanent or temporary 

installations.  To minimize bends in the gun hose, orient the 

console so that the open end points toward the work area 

and the male connector points toward the air supply.
1.  Use the included screws to attach the supplied

 

mounting plate to the threaded holes on the back of the

 

console.

Figure 7: Connecting the hose and disposable filter to the 

console

2.  Connect the hose and disposable filter to the console.

 

Press the disposable filter release button on the front of

 

the console to lock it down.  Push the fitting containing

 

the disposable filter all the way into the opening in the

 

console until it latches with a click.  It fits only in the

 

correct orientation.  The small plastic fitting on the end

 

of the disposable filter must align with the metal guide

 

coupling in the console.  You may have to wiggle the

 

disposable filter slightly while inserting it.

2.  Attach the plate to a flat surface, such as a wall or back

 

of a work bench, using suitable screws and fasteners.

 

When mounting to a hollow wall be sure to use #8

 

screws and 3/4” length anchors as a minimum.

MOUNTING TO A GAS SUPPLY

When a gas supply is close to the work area and fitted 

with a standard industrial interchange quick coupling, you 

may attach the console to the air supply fitting directly.  If 

necessary, use a prefilter as defined in the COMPRESSED 

GAS REQUIREMENTS section of this technical bulletin.

ASSEMBLY

NOTE: Protect the hose from sharp objects, abrasion, and 

high temperatures.  Do not pull or pinch the hose while 

assembling the components.
1.  Insert the larger diameter end of the air filter into the

 

end of the flexible air hose connector.  Press the metal

 

filter release tab at the end of the hose until it locks into

 

place.

3.  Attach the included 1/4” NPT female quick connect

 

fitting to your gas supply line.  Slide the outer ring on

 

the fitting towards the supply line to insert the mating

 

fitting on the console.  You can attach the console

 

directly to the gas supply pipe or attach it using a hose

 

(not supplied).  If necessary, use a prefilter as defined

 

in the COMPRESSED GAS REQUIREMENTS section

 

of this technical bulletin.

4.  If you would like to use the optional foot switch, plug its

 

cable to the jack located at the top of the console.

Operation

NOTE: Our recommendation is to set the pressure regulator 

on your air or nitrogen supply between 20 and 65 psi 

(0.14-0.45 MPa).  Discharge times vary depending on air 

pressure.
Pressures of 30-40 psi (0.2-0.28 MPa) are commonly 

used for decontaminating surfaces.  OSHA regulations 

recommend limiting hand-held air blow-off devices to 

maximum pressures of 30 psi (0.2 MPa).  The hose is rated 

at 65 psi (0.45 MPa) at temperatures up to 75°F (24°C), and 

the rating decreases at higher temperatures.  When using 

high pressures, consider the ambient room temperature as 

well as heat from surrounding equipment.
1.  Ensure that you are not holding down the trigger, and

 

turn on the power switch located at the top of the

 

console.  The power LED should illuminate.