VPAC/VPHP

!  

!  

CONTROL BOX MOUNTING

The VPAC/VPHP control box is factory mounted in the 

front position unless otherwise specified. On larger capacity 

units (19-24 only), the control box can be field modified for 

left or right side applications by removing the four screws 

that attach it to the front control box mounting brackets and 

reattaching it to the corner posts using the same four screws. 

(Figure 5).

 The control box can be factory mounted for left or 

right side applications on the smaller capacities (9-17) but it 

is not recommended for field modification at this time.

INSTALLATION FOR NEW CONSTRUCTION 

Continued

 VPAC/VPHP INDOOR MOTOR SPEED 

TAP SELECTION CHART

Figure 4 

IMPORTANT:

 

Some  wire  ties  around  the  main  wire 

harness will need to be cut in order to move the control 

box from the front position.

LEFT/RIGHT SIDE CONTROL APPLICATIONS

A. Remove applicable side panel from chassis.

B.  Slide  chassis  into  wall  sleeve,  assuring  that  wall 

sleeve studs align with the holes just above the con-

denser coil.

C. Attach wall sleeve to back panel of chassis using the 

two 1/4-20 nuts 

(see Figure 1 for detailed illustration and 

Figure 3 for location of mounting holes)

.

D. Replace side panel on chassis.

E. Attach applicable weather angle to chassis and wall 

sleeve using one 1/4-20 nut (provided).

2. Install plenum and duct work.

3. Plug in the supplied low voltage harness and run it to 

the wall thermostat as shown in the unit’s wire diagram.

4. If the unit is equipped with a drain stub in the base 

pan,  connect  the  drain  stub  to  the  building’s  internal 

condensate removal system. 

If  the  unit  is  not  equipped  with  a  drain  stub,  a  minimal 

amount of condensate will, during the heating cycle, run 

out the  wall sleeve, onto the drip edge, and away from 

the building when the drain pan valve opens. During the 

cooling cycle, condensate will be funneled to an area near 

the condensing fan and picked up by the slinger ring. The 

condensate will be slung against the hot condenser coil to 

evaporate. Any excess condensate due to rain or humidity 

will overflow through notches in the rear of the base pan 

and again run out the  wall sleeve, onto the drip edge, and 

out of the building.

INDOOR MOTOR SPEED TAP SELECTION

WARNING

Before accessing the control compartment, disconnect 

power to the unit. Failure to do so could result in serious 

injury or electrical shock.

For information on indoor motor speed tap selection, 

please  refer  to  the  “Indoor  Motor  Speed Tap  Selection 

Chart”  label  attached  to  the  chassis  of  the  VPAC/VPHP 

(Figure 4)

.

The motor comes factory wired for the corresponding 

units as described in the 230V column. Please make speed 

tap changes as required by job site voltage and/or external 

static pressure (e.s.p.) Speed tap changes may need to be 

changed from factory settings and enviromaster interna-

tional will not be liable for any system problems that could 

arise if motor speed is not changed to match application.

Unit Size

ESP

230V

208V

197V

9

0.1

Red

Red

Red

0.2

Red

Red

Blu

0.3

Red

Blu

Blu

12

0.1

Blu

Blu

Blu

0.2

Blu

Blu

Blk

0.3

Blu

Blk

Blk

15

0.1

Blk

Blk

Blk

0.2

Blk

Blk

Blk

0.3

Blk

Blk

Blk

17-19

0.1

Red

Red

Red

0.2

Red

Blk

Blk

0.3

Blk

Blk

Blk

24

0.1

Blk

Blk

Blk

0.2

Blk

Blk

Blk

0.3

Blk

Blk

Blk

Tap Key -

 Red (Low) - Blu (Med) - Blk (High)

VPAC/VPHP 19-24 CONTROL BOX MOUNTING

Figure 5 

Control Box 

(Mounting brack-

ets not required 

for left/right side 

mounting)

Control Box

Front Control 

Box Mounting 

Brackets

Содержание VPAC

Страница 1: ...00 Certified Company VPAC VPHP SINGLE PACKAGE VERTICAL AIR CONDITIONER HEAT PUMP FOR NEW CONSTRUCTION ONLY Straight Cool Heat Pump Nominal Capacities 9 000 12 000 15 000 17 000 19 000 24 000 Btuh VPAC VPHP Enviromaster International LLC 5780 Success Dr Rome NY 13440 Email info retroaire com ...

Страница 2: ... stated on the rating plate Have proper over current protection i e time delay fuse HACR Breaker as listed on the Rating Plate Failure to follow these instructions can result in a fire explosion or electrical shock causing property damage personal injury or death This manual is intended as an aid to qualified service personnel for proper installation operation and maintenance of the VPAC VPHP Packag...

Страница 3: ...allation Instructions 5 9 Sequence of Operation 10 12 Cleaning and Maintenance 12 Troubleshooting 12 Specifications and Dimensions 13 14 Warranty 15 INSTALLER RESPONSIBILITIES This manual has been prepared to acquaint you with the installation operation and maintenance of this VPAC VPHP PTAC and to provide important safety information in these areas We urge you to read all of the instructions thoro...

Страница 4: ...ess panel standard white or custom colors available PRODUCT DESCRIPTION The VPAC VPHP Single Package Vertical Air Condi tioner SPVAC and Heat Pump SPVHP creates new op tions in layout and space utilization The VPAC VPHP offers low cost operation and quiet comfortable air distribution especially when used in multi room suites apartments healthcare facilities and homes Framed into a concealed closet...

Страница 5: ... position necessary for installation Figure 1 INSTALLATION FOR NEW CONSTRUCTION EXPLODED VIEW OF TYPICAL INSTALLATION Rear View of Door Filter Slide On Back Access Panel Optional Evaporator Coil Manual Fresh Air Door External line cord min 48 located at bottom right for front and right hand controls or bottom left for left hand controls Minimum overall wall thickness must be at least 5 for straigh...

Страница 6: ...VPHP WALL SLEEVE ASSEMBLY CROSS SECTION OF TYPICAL WALL Wall Sleeve Outdoor Louver Interior Wall Lag Holes 4 On Each Side Wall Sleeve Depth Overall Wall Thickness 1 25 Louver Depth 1 2 x 1 2 Foam Gasket Overall Wall Thickness DETERMINING WALL SLEEVE DEPTH Figure 2 Weather Angle Position INSULATION WEATHER ANGLES Back Panel Mounting Holes Install supplied 1 2 x 1 2 foam insulation along top and sid...

Страница 7: ...ot equipped with a drain stub a minimal amount of condensate will during the heating cycle run out the wall sleeve onto the drip edge and away from the building when the drain pan valve opens During the cooling cycle condensate will be funneled to an area near the condensing fan and picked up by the slinger ring The condensate will be slung against the hot condenser coil to evaporate Any excess co...

Страница 8: ...t or front aligned matching the control section alignment of the unit on which it is to be installed 1 The coil package is centered on top of the VPAC VPHP chassis Make sure it is centered over the fan discharge and that the piping package is in the correct position 2 Find the two Z brackets used to clamp the hydronic enclosure to the chassis top Mount these brackets to the chassis top using the h...

Страница 9: ...se as a temporary heating cooling source during construction MANUAL FRESH AIR DAMPER The fresh air manual damper allows the user to move fresh air into the space to be conditioned The damper handle is located below the evaporator coil on the service panel RETURN AIR ACCESS PANEL NOTE Available with solid doors if separate intake is used B C A Frame Assembly Lag Holes 1 5 Rear View Of Door G NOTE A...

Страница 10: ...e adjustment screw is tampered with it will be necessary to reset the freeze stat To set the freeze stat you will need a medium flat bladed screwdriver Turn the adjusting screw counter clockwise until it stops Then slowly turn the ad justing screw clockwise approximatly 1 8 turn until a click is detected The freeze stat is now set CHOOSING A THERMOSTAT Enviromaster International offers a thermostat...

Страница 11: ...valve that will open when outdoor temperatures fall below 50 F This keeps the base pan free of condensate water where it may otherwise freeze during colder outdoor temperatures As part of its normal operation the unit will produce condensate and collect it in the base pan of the unit There it will be picked up by the condenser fan slinger ring and deposited onto the condenser coil During the cooli...

Страница 12: ...lies Some units may require a drop of light oil to motors and or bearing assemblies look for oil cups Check setscrews and motor mounting hardware making sure these are tight 6 Centrifugal fan blades and blower cage assemblies must be clean to operate efficiently Brush and or vacuum as necessary 7 Inspect both indoor and outdoor coils Use a fin comb to straighten out any damaged fins These coils must...

Страница 13: ...5 60 1 0 70 0 125 4 25 26 0 67 0 08 5 62 240 6 7 15 H WIRE 15 208 230 60 1 0 72 0 125 6 40 35 0 80 0 07 7 92 197 9 6 15 6 15P 265 60 1 0 70 0 125 5 40 32 0 67 0 08 6 77 240 8 2 15 H WIRE 17 208 230 60 1 1 20 0 250 7 40 48 1 00 0 15 9 60 197 11 5 15 6 15P 265 60 1 1 30 0 250 6 50 44 0 67 0 08 8 50 240 10 1 15 H WIRE 19 208 230 60 1 1 00 0 250 7 40 48 1 00 0 15 9 40 197 11 3 15 6 15P 24 208 230 60 1...

Страница 14: ... 15 7 17 2 21 2 25 6 30P 230 4000 13700 17 4 18 9 23 2 25 6 30P 265 5310 18200 20 0 21 5 26 5 30 H WIRE 5 208 4089 14000 19 7 21 2 26 1 30 6 30P 230 5000 17100 21 7 23 2 28 7 30 6 30P 7 208 5725 19600 27 5 29 0 35 9 40 H WIRE 230 7000 23900 30 4 31 9 39 5 40 H WIRE 265 6635 22700 25 0 26 5 32 8 35 H WIRE 277 7250 24800 26 2 27 7 34 2 35 H WIRE 10 208 8178 28000 39 3 40 8 50 6 60 H WIRE 230 10000 3...

Страница 15: ...nditions blown fuses open circuit breakers or other damages due to the inadequacy or interruption of electrical service Damage or repairs needed as a consequence of any misapplication abuse improper servicing unauthorized alteration or improper operation Damage as a result of floods winds fires lightening accidents corrosive atmosphere or other conditions beyond the control of EMI Parts not supplied...

Страница 16: ......

Отзывы: