www.enviromaster.com
5
WLCA/WLHA High Wall Evaporator
itEms for ConsidErAtion
Determine the best location for mount
-
ing the unit for room air circulation.
Locate outdoor and indoor units as
close together as possible.
Determine how power wire (high and
low voltage) condensate drainage,
and refrigerant piping may be run to
and from the unit.
WLC/WLH
- Ensure that intercon-
nect tubing is within the maximum
allowable length of 100’ including a
maximum 35’ lift.
To ensure serviceability and proper
air distribution, the unit should be
positioned as close as possible to the
center (left-to-right) of the wall. Minimum
distance from the ceiling is stated on the
template provided with the unit packag
-
ing. The cabinet left and right end caps
must be accessible for removal without
obstruction.
(See below)
•
Modular design –
reduces parts
required for control package. Deco
panel, relay board, ribbon cables and
microprocessor are combined into one
package.
•
Integral condensate pump safety-
switch connection
where-by the mi
-
croprocessor monitors the condensate
pump safety switch and displays an
error code when a fault occurs.
(Applies
only with optional
condensate
pump)
•
CEC
(California Energy Commission)
compliant
• Condensate drain pan over flow
protection
Cabinet Features:
• Durable ABS plastic cabinet with a
galvanized steel sub-chassis.
• Easily accessible, washable, reusable,
nylon mesh filter.
• Horizontal discharge louver, construct
-
ed of high temperature ABS plastic,
that can be set to oscillate, or can be
parked in six pre-set positions.
• Manually adjustable vertical discharge fins.
• Easy access to pipe chase area from
cabinet bottom allows piping connec
-
tions and condensate pump installation
with the unit mounted on the wall.
• Easily removable end-cap for access to
control area for installation and service.
• Condensate drain pan constructed of
galvanized steel (G90U), with anti-cor
-
rosion coating.
• Modular snap-in, 7-day programmable
control with large backlit LCD display,
a “Change filter” display feature and
selectable Fahrenheit (Fº), or Celsius
(Cº) temperature scale.
WLC/WLH ControLs And ComponEnts
Continued
optionAL EqUipmEnt
• Condensate pump
(field installed only)
• 24V remote wall thermostat
• Electric heat with automatic reset high
temperature cutout and redundant
high temperature fuse link (when heat
option is selected)
•
H
and held infrared controller.
instALLEr sUppLiEd itEms
• Low voltage wiring
(18 awg required)
• High voltage power supply wiring
• Mounting screws and fasteners
• Condensate piping
• Refrigerant piping (if not supplied)
• Refrigerant (for interconnect charge)
IMPORTANT:
Check equipment for damage
prior to installation, if damaged contact the
wholesale distributor.
CEiLinG
W
ALL
W
ALL
4” Minimum
10”
Minimum
6”
Min.
notE:
Unit mounted controls are fully func
-
tional without the remote.
NOTE:
If the control is configured for unit
mount control do NOT connect a wall ther
-
mostat to the unit.
Содержание AmericaSeries WLC30
Страница 2: ......