Tool Operation – Cont’d
RELOADING THE TOOL
Once all of the rivets on the Rivet Tape are used, the Rivet
Tape needs to be removed to load the next coil.
1.
With the air supply on, pull the Trigger on the tool and hold
it so that the Nose Piston remains in the back position.
2.
While holding the Trigger, turn off the air supply by sliding
the Valve Sleeve on the Air Hose away from the tool.
3.
Firmly grasp the empty Rivet Tape and pull it away from
the tool as shown in Figure 8.
4.
Empty the spent mandrels from the MCS chamber.
5.
Turn on the air supply so that the Nose Piston returns to
the forward position.
!
Keep your hands away from the Nose Piston when it
cycles forward !
6.
Reload the tool as described in the “LOADING RIVET
TAPE” section.
Figure 8:
Rivet Tape removal.
REMOVING PARTIALLY USED RIVET TAPE
If the situation arises where the operator desires to switch to a
different rivet while there are still rivets in the tool, the Rivet
Tape can be removed as follows:
1.
Turn off the air supply to the tool and open the Magazine.
2.
Remove 4 or 5 rivets from the Tape that are closest to the
Nose Piston.
3.
With a pair of scissors, cut the tape at the point where you
removed the rivets.
4.
Remove the remaining rivets from the Magazine and
remove the spent Rivet Tape as described in the
“RELOADING THE TOOL” section.
5.
Reload the tool as described in the “LOADING RIVET
TAPE” section.
Emhart Teknologies