Preparation for Operation
Before operating the tool check the following:
•
Inspect the tool for damage and/or signs of wear and replace or repair parts as required.
DO NOT
use the tool if damaged.
•
If using inline lubrication, check the adjustment on the Lubricator and make sure there is an adequate oil supply. The Lubricator
should be as close to the tool as possible.
•
If using manual lubrication, check to see if the tool needs to be lubricated as prescribed in the Maintenance Manual.
•
Check the Air supply pressure and make sure it is between 85-100 PSI (5.8-6.9 Bar).
•
Check the tool air hose for wear or damage and replace if necessary.
•
If suspending the tool via a Tool Balancer or other device, check to make sure the tool is secure.
•
Check that the proper Nosepiece is installed for the rivet to be used.
•
Empty the Mandrel Collection System of all spent mandrels.
Tool Operation
AIR FITTING OPERATION
The air fitting supplied with the AutoSet
®
tools has an On/Off
flow valve built into it. To operate the valve, do the following:
1.
Push the female Quick-connect hose fitting over the male
fitting on the AutoSet
®
tool. When fully connected you will
see a blue Indicator Ring (Fig. 4).
2.
To turn on the air supply to the tool, slide the Sleeve
toward the blue Indicator Ring.
3.
To lock the fitting so that the air does not accidentally get
shut off, twist the Collar and Sleeve so that the Locking
Arrows line up.
LOCK
AIR SUPPLY OFF
AIR SUPPLY ON
SLEEVE
BLUE INDICATOR RING
LOCK ARROWS
COLLAR
Figure 4:
Tool Air Supply fitting.
NOSEPIECE SELECTION
Open End Rivets (All Materials) &
Closed End Rivets (Al/Al)
Closed End Rivets
(Al/St)
Rivet Size
Domed
Countersunk
Domed
Countersunk
1/8” (3.2mm) diameter rivets
DP220-501 DP220-527 DP220-500 DP220-525
5/32” (4mm) diameter rivets
DP220-502 DP220-528 DP220-501 DP220-527
3/16” (4.8mm) diameter rivets
DP220-503 DP220-529
N/A
N/A
Al / Al = Aluminum Body and Mandrel
Al / St = Aluminum Body and Steel Mandrel
Emhart Teknologies
- 50 Shelton Technology Center, Shelton CT 06484 - Tel. (203) 924-9341 - Fax (800) 225-5614 Page