15
emersonfans.com
Please contact 1-800-654-3545 for further assistance
ETL Model No.: CF530
6. How to Wire Your Wall Control
(continued)
Figure 23
DASH LINES ARE 3
CONDUCTOR CABLE
W/GROUND WIRE
BETWEEN CEILING
AND WALL OUTLET
BOXES
120V AC
SUPPLY
SOURCE
BLACK
WHITE
GROUND
GREEN
WHITE
BLACK
BLUE
WALL OUTLET
BOX GROUND
BLUE
BLACK
BLACK/WHITE
FAN/LIGHT
CONTROL
CEILING OUTLET BOX
BLUE
Schematic “A”
CONNECTIONS REQUIRED WHEN SUPPLY VOLTAGE IS FED INTO CEILING OUTLET BOX.
DASH LINES ARE 3
CONDUCTOR CABLE
W/GROUND WIRE
BETWEEN CEILING
AND WALL OUTLET
BOXES
GREEN
WHITE
BLACK
BLUE
120V AC
SUPPLY
SOURCE
BLACK
WHITE
GROUND
BLUE
BLACK
FAN/LIGHT
CONTROL
BLACK/WHITE
CEILING
OUTLET
BOX
BLUE
Schematic “B”
CONNECTIONS REQUIRED WHEN SUPPLY VOLTAGE IS FED INTO WALL OUTLET BOX.
NOTE: Refer to Schematic “A” or “B”, depending upon the location of your 120V AC supply source
(Figure 23).
NOTE: This wiring configuration will control accent/light and accessory downlight together. For other
possible wiring/switch combinations to control accent light and downlight, consult a licensed electrician
or see other Emerson accessory control.