background image

11

emersonfans.com

Please contact 1-800-654-3545 for further assistance

ETL Model No.: CF530

5. Ceiling Fan Assembly

(continued)

1/4-20 x 1/4" ROUND 
HEAD SCREWS WITH 
LOCKWASHERS (5)

FLYWHEEL

Figure 13

5.3

Place the flywheel onto the fan motor. 

Align the five screw holes of the flywheel on the fan
motor.

Secure the flywheel to the fan motor using the five
1/4-20 x 1/4” round head screws with lockwashers
(provided) (Figure 13).

#6-32 x 1/4" TRUSS 
HEAD SCREW WITH 
LOCKWASHER (3)

LIGHT KIT 
ADAPTER

Figure 15

5.5

Remove one #6-32 x 1/4” truss head screw with
lockwasher (retain for future use). Loosen the two other
#6-32 x 1/4” truss head screws with lockwashers for
installation of light kit housing adapter (Figure 15).

Slide the fan motor wiring and connector through the
center hole of the light kit housing adapter. 

Position the light kit housing adapter onto the fan motor.
Rotate the light kit housing adapter to engage the two
keyhole slots. 

Reinstall the previously removed #6-32 x 1/4” truss
head screw with lockwasher into the remaining hole of
the light kit housing adapter. Tighten the three screws
and lockwashers to secure the light kit housing adapter
to the fan motor (Figure 15).

FAN BLADE (4)

FLYWHEEL 
SLOT(4)

#8-32  x 11mm TRUSS 
HEAD BLADE SCREW 

(3 PER BLADE)

Figure 14

5.4

Carefully place the fan blade (“THIS SIDE UP” label
should face the mating surface of the flywheel) into the
slot of the flywheel (Figure 14).

Securely install the three #8-32 x 11mm truss head
blade screws per blade to fan motor (Figure 14).

Complete the remaining three blades installation per the
above instructions.

NOTE: Take care not to scratch flywheel when
installing blades

BP7484 Wyatt CF530  12/18/13  11:52 AM  Page 11

Содержание WYATT CF530BS00

Страница 1: ... Manual CF530BS00 Brushed Steel CF530ORB00 Oil Rubbed Bronze CF530WW00 Appliance White Model Numbers Net Weight 16 2 Lbs Questions problems missing parts Before returning to the store call Emerson Electric Customer Service 8 a m 6 p m Eastern Monday Friday 1 800 654 3545 www emersonfans com BP7484 Wyatt CF530 12 18 13 11 52 AM Page 1 ...

Страница 2: ...gh about electrical wiring have your fan installed by a licensed electrician WARNING To reduce the risk of electrical shock this fan must be installed with an isolating wall control switch NOTE This fan is suitable for use with solid state speed controls WARNING This product is designed to use only those parts supplied with this product and or any accessories designated specifically for use this p...

Страница 3: ...owing parts NOTE If you are uncertain of part description refer to exploded view illustration below NOTE Place the parts from the loose parts bags in a small container to keep them from being lost If any parts are missing call 1 800 654 3545 for replacement parts before proceeding PACKAGE CONTENTS 1 2 5 4 4 3 6 Part Description Quantity A Ceiling Mounting Plate 1 B Fan Motor 1 C Fan Motor Housing ...

Страница 4: ...tor 2 wire with ground of following size Installed Wire Length Wire Size A W G Up to 50 ft 14 50 100 ft 12 4 ETL Model No CF530 2 Electrical Requirements Your new ceiling fan will require a grounded electrical supply line of 120 volts AC 60 Hz 15 amp circuit To reduce the risk of fire electric shock or personal injury mount fan to outlet box marked Acceptable for Fan Support of 22 7 kg 50 lbs or l...

Страница 5: ...RNING Turning off wall switch is not sufficient To avoid possible electrical shock be sure electricity is turned off at the main fuse box before wiring All wiring must be in accordance with National and Local codes and the ceiling fan must be properly grounded as a precaution against possible electrical shock WARNING 3 1 Disconnect electrical power to the branch circuit at the circuit breaker or f...

Страница 6: ...motor onto the ceiling mounting plate hook during wiring fan motor assembly to outlet box Figure 3 FAN MOTOR BRACKET RUBBER BOOT 4 STEEL BUSHING 4 Figure 4 3 4 Insert each steel bushing 4 supplied in parts bag into the four rubber boots until they are flush with the top surface of each rubber boot Figure 4 BP7484 Wyatt CF530 12 18 13 11 52 AM Page 6 ...

Страница 7: ...ground and that no bare wire is visible at the wire connectors except for the ground wire 4 2 Securely connect the green grounding wire from the fan motor mounting bracket the green grounding wire from the ceiling mounting plate and the green grounding wire from the supply conductor this may be a bare wire or a wire with green insulation Figure 5 Turning off wall switch is not sufficient To avoid ...

Страница 8: ...R BLUE WIRE Figure 8 BLACK SUPPLY WIRE RED SUPPLY WIRE WHITE SUPPLY WIRE GROUNDING SUPPLY WIRE 3 CONDUCTOR CABLE W GROUND WIRE BETWEEN CEILING AND WALL OUTLET BOXES BLACK FAN WIRE WHITE FAN WIRE FAN MOTOR MOUNTING BRACKET GREEN GROUNDING WIRE BLUE FAN WIRE CEILING MOUNTING PLATE GREEN GROUNDING WIRE Figure 9 4 5 Securely connect the supply red wire to the fan blue wire Figure 8 NOTE This fan requi...

Страница 9: ... OUTLET BOX Figure 10 4 How to Wire Your Ceiling Fan continued 4 6 After connections have been made turn leads upward and carefully push leads into the outlet box with the white and green leads on one side of the outlet box and the black and blue leads on the other inside of the outlet box Figure 10 BP7484 Wyatt CF530 12 18 13 11 52 AM Page 9 ...

Страница 10: ...the motor housing Figure 12 To avoid possible fire or shock make sure that the electrical wires are completely inside the outlet box and not pinched between the ceiling mounting plate and the fan motor WARNING NUTS AND WASHERS 4 ROTATE FAN MOTOR UP AND ALIGN ONTO FOUR THREADED STUDS THREADED STUDS 4 FAN MOTOR Figure 11 5 1 Remove the four nuts and flat washers from the ceiling mounting plate screw...

Страница 11: ...or through the center hole of the light kit housing adapter Position the light kit housing adapter onto the fan motor Rotate the light kit housing adapter to engage the two keyhole slots Reinstall the previously removed 6 32 x 1 4 truss head screw with lockwasher into the remaining hole of the light kit housing adapter Tighten the three screws and lockwashers to secure the light kit housing adapte...

Страница 12: ...HEAD SCREWS 2 loosened Figure 17 5 7 Remove two M4 x 6mm pan head screws opposite of each other retain for future use from the light kit housing adapter in preparation of installing the light kit fixture Figure 17 Loosen the remaining two M4 x 6mm pan head screws from the light kit housing Figure 17 Carefully tuck all wires and connectors into the light kit fixture Place the light kit fixture onto...

Страница 13: ... FLAT AREA 3 GLASS SHADE Figure 19 5 9 Place the glass shade into the opening in the light kit assembly aligning the three flat areas on the top edge of the glass with the three raised dimples on the light kit assembly and turn the glass shade clockwise until it stops Figure 19 NOTE Periodically check that the glass shade is seated fully clockwise in the light kit assembly Please call Emerson tech...

Страница 14: ...sition Figure 21 Make the following wire connections Figure 21 and secure with wire connectors supplied Black wire from fan to black wire from fan light control White wire from fan to white wire from the 120V AC supply source Blue wire from fan to blue wire from fan light control Black white wire from fan light control to black wire from the 120V AC supply source EMERSON TO HOT BLACK WHITE SPEED S...

Страница 15: ...ES ARE 3 CONDUCTOR CABLE W GROUND WIRE BETWEEN CEILING AND WALL OUTLET BOXES GREEN WHITE BLACK BLUE 120V AC SUPPLY SOURCE BLACK WHITE GROUND BLUE BLACK FAN LIGHT CONTROL BLACK WHITE CEILING OUTLET BOX BLUE Schematic B CONNECTIONS REQUIRED WHEN SUPPLY VOLTAGE IS FED INTO WALL OUTLET BOX NOTE Refer to Schematic A or B depending upon the location of your 120V AC supply source Figure 23 NOTE This wiri...

Страница 16: ...d 1 4 0 position is OFF Figure 24 7 2 NOTE Remove the glass shade from the light kit assembly to expose the reverse switch All fans are shipped from the factory with the reversing switch positioned to circulate air downward If airflow is desired in opposite direction turn your fan OFF and wait for the blades to stop turning then slide the reversing switch to the opposite position and turn fan on a...

Страница 17: ...fan could result in fire shock and personal injury WARNING Do not use water when cleaning your ceiling fan It could damage the motor or the blades and create the possibility of an electrical shock WARNING IMPORTANT CARE INSTRUCTIONS for your Ceiling Fan Periodic cleaning of your new ceiling fan is the only maintenance that is needed When cleaning use only a soft brush or lint free cloth to avoid s...

Страница 18: ...18 ETL Model No CF530 10 Repair Parts 4 3 2 1 EMERSON 2 3 5 6 8 1 10 11 9 10 4 14 11 12 12 13 7 14 15 13 BP7484 Wyatt CF530 12 18 13 11 52 AM Page 18 ...

Страница 19: ...g Mounting Plate 1 764539 764539 764539 2 Fan Motor Housing 1 764541 BS 764541 ORB 764541 WW 3 Flywheel 1 764545 BS 764545 ORB 764545 WW 4 Fan Blades set of 4 764548 BS 764548 ORB 764548 WW 5 Light Kit Adapter 1 764540 764540 764540 6 Light Kit Assembly 1 764550 764550 764550 7 50W Mini Candelabra Base Halogen Bulb 1 8 Glass Shade 1 764554 OM 764554 OM 764554 OM 9 Wall Control 1 SW90W SW90W SW90W ...

Страница 20: ...using adapter WARNING Make sure main power is turned OFF 3 Fan wobbles 1 Blades are not tightly fastened to the fan 1 Check all blade screws for tightness excessively WARNING Make sure main power is turned OFF 2 Fan blades out of balance 2 Interchange an adjacent side by side blade pair to redistribute the weight Locate the supplied blade balancing kit and follow the included instructions 4 Lamp w...

Страница 21: ...e user is encouraged to try to correct the interference by one or more of the following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver Connect the equipment into an outlet on a circuit different from that to which the receiver is connected Consult the dealer or an experienced radio TV technician for help This equipment has been certif...

Страница 22: ...22 ETL Model No CF530 Notes BP7484 Wyatt CF530 12 18 13 11 52 AM Page 22 ...

Страница 23: ...mer Service at 1 800 237 6511 to obtain a return authorization and service identification tag In order for us to confirm that your Emerson Ceiling Fan is still under warranty please retain your receipt or other proof of purchase and have that information readily available when returning your Emerson Ceiling Fan to your place of purchase or upon calling Emerson Customer Service If you call Emerson ...

Страница 24: ...stern Monday Friday 1 800 654 3545 www emersonfans com Retain this manual for future use Air Comfort Products DIVISION OF EMERSON ELECTRIC CO 8100 W Florissant St Louis MO 63136 Part No F40BP74840000 Form No BP7484 Revision 131218 ETL Model No CF530 Printed in China 12 13 BP7484 Wyatt CF530 12 18 13 11 52 AM Page 24 ...

Отзывы: